13-5
SECTION 13
SLIDEOUT ROOM
14 - SLIDEO
UT R
OOM
13 - SLIDEOUT ROOM
NOTE: Attempting to crank the room in too
quickly will raise pressure in the hydrau-
lic fluid lines and make cranking more
difficult.
Step 3 - Secure Travel Straps and Close
Hydraulic Line Valves
•
Fasten the slideout room Travel Straps.
•
Close the slideout solenoid valves complete-
ly.
NOTE: Close the valves snugly, but do not over-
tighten. Overtightening may cause inter-
nal damage to the valves.
•
See your dealer for service of the room exten-
sion system before using again.
BEDROOM SLIDEOUT
EMERGENCY RETRACTION
In the unlikely event that your bedroom slide-
out fails to retract using the power switch, check
for obvious causes first, such as low charge on
the house batteries, or a burned out fuse on the
chassis fuse block. (See “Troubleshooting” else-
where in this section.)
NOTE: Check fuses #16 Step Alarm and #24 Ra-
dio/Acc. There is also a fuse on the back
of the HWH leveling system control pad,
which must be unfastened from the driver
door to inspect.
If an apparent cause is not found, call a road-
side service center or your Winnebago Industries
dealer to dispatch a service vehicle to your loca-
tion to push the room extension in so the coach
may be driven to a Winnebago Industries dealer
for service of the slideout control system.
NOTE: The following information may be needed
by the service operator to prepare the
bedroom slideout for the “push-in” pro-
cedure.
Bedroom Slideout
Emergency ‘Push-In” Procedure
•
Open the “slideout” hydraulic line valves on
the pump to relieve hydraulic line pressure.
(See photos on previous page.)
•
DO NOT OPEN THE JACK VALVES ON
THE RESERVOIR SIDE OF THE PUMP.
These regulate the coach leveling jacks.
•
Apply a steady inward pressure of approxi-
mately 150 lbs. to the exterior sidewall of the
slideout room to push the room in toward the
coach until it is snug against the main coach
sidewall.
•
NOTE: Use some type of rigid, padded mate-
rial to protect the sidewall from punctures,
dents or other damage to the finish from any
device or equipment used to press the side-
wall in
.
•
Pressure must be applied evenly to avoid
binding of the hydraulic mechanism. It may
take about 10 minutes to press the room
extension inward completely.
•
When the room is snug against the coach
wall, close the solenoid valves to prevent
“creep out” during transit.
See an Authorized Winnebago Industries
Dealer
for service of the slideout system before
using again.
NOTE: When the system has been corrected,
check hydraulic fluid level and refill res-
ervoir as necessary. Press the Retract
switch for 15 to 20 seconds before at-
tempting to extend the room. Then run
the room out and in several times to
purge any air from the hydraulic system.
Finally, recheck fluid level and fill as
necessary.
Further Information
See the HWH Hydraulic Room Extension
operating guide included in your Owner InfoCase
for further instructions and troubleshooting infor-
mation.
The Retract Bolts must be ‘backed
out’ to their original positions imme-
diately after the crank-in procedure to
avoid damaging the retract bolts and
slideout mechanism the next time the
room is extended.
CAUTION