Stacking packages weighing over 60kg/m² is strictly prohibited, irrespective of their position. 

Dear Sir/Madam, 
  
You have acquired a WINNCARE medical accessory, and we thank you for your custom. 
  
Our medical support systems (MSSs) and their accessories are designed and manufactured in compliance with 
the essential requirements applicable thereto of European Directives 2007/47/EC. 
 
  
They  are  tested  in  conformity  with  standard  EN  60601-2-52  (2010)

 

in  their  commercial  configurations, 

including  the  boards  and  accessories  that  we  manufacture,  so  as  to  ensure  you  maximum  safety  and 
performance.
 
 
As a result, maintenance of the contracted good’s warranty depends on compliance with the conditions for use 
recommended by WINNCARE and the use of original boards and accessories, which also guarantees you safe 
use of the medical MSS and its accessories. 

 
 

1. TRANSPORT CONDITIONS 

 
During transport, the mobility support system must be strapped and protected by plastic packaging. 
 
NB: stacking packages on the mobility support systems is strictly prohibited. 
 
 
 
 

2. STORAGE CONDITIONS 

 
The mobility support system must be stored at a room temperature of between -10°C and +50°C, and relat ive 
humidity of between 30% and 75%. 
 
Atmospheric pressure between 700hPa and 1060hPa

 

under the same conditions as for transporting. 

 
 

 

 

Содержание SAM Ergonom A618-00

Страница 1: ...2 51 98 59 07 Email info medicatlantic fr Site Internet http www winncare fr USER S MANUAL Mobility Support Systems A649 00 A650 00 SAM Ergonom A647 00 A648 00 SAM Ergonom plus A651 00 A652 00 SAM Erg...

Страница 2: ...S A647 00 A648 00 A649 00 A650 00 A651 00 A652 00 6 4 CONDITIONS FOR USE 7 4 1 FUNCTION 7 4 2 USE 8 4 3 PRECAUTIONS FOR USE 9 4 4 RESIDUAL RISKS 9 5 MAINTENANCE CONDITIONS 9 5 1 IDENTIFICATION 9 5 2 U...

Страница 3: ...nsure you maximum safety and performance As a result maintenance of the contracted good s warranty depends on compliance with the conditions for use recommended by WINNCARE and the use of original boa...

Страница 4: ...0 A628 A629 00 IXP4L A647 A648 00 A649 A650 00 A651 A652 00 IAE2L AE2 A647 A648 00 A649 A650 00 A651 A652 00 IXX1L A614 A615 00 A618 A619 00 A628 A629 00 IAE3L AE3 A647 A648 00 A649 A650 00 A651 A652...

Страница 5: ...the grip jaws Position the grip jaws as shown in the diagrams below In order to assemble them on the bed the longest section on the head end must be positioned by tightening the two adjustment knobs u...

Страница 6: ...oning the nut on the inner side of the bed 3 Screw the jaw with the screw and nut provided with an Allen wrench n 4 Insert pole of the side rail in the jaw on the head side fixed on the bed until to h...

Страница 7: ...t should preferably be carried out of the mobility support system to decide whether or not to use it This assessment must take the following into account the department s surveillance capacities A sta...

Страница 8: ...site the SAM to move towards the exit of the bed when you pull toward you with your arms the handle of the SAM The turning handle is raised only when the barrier is folded back It allows the patient t...

Страница 9: ...ake sure not to rub the side handle along vertical walls When the bed is placed in low position ensure that nothing or no area of the patient s or carer s body is between the bed boards accessories an...

Страница 10: ...neat Persistence time must be applied according to the disinfectant manufacturer drying time often equals the persistence time excluding human presence SANIVAP type steam device with accessories 5 4...

Страница 11: ...protect the disinfected equipment from other equipment that has not been disinfected by a film and a label indicating the disinfection date 5 5 Lifetime The lifetime under normal conditions of use an...