VERSION 1
05/01/2021
I
NSTALLATION AND
U
SAGE
G
UIDE
WINESP40CEPRO
Page 22
4
STARTING UP THE WINEMASTER
®
AIR CONDITIONER
The thermostat displays the air temperature inside the air-conditioned room within a range of 2°C. The
thermostat is factory set for a setting of 12°C. When the air conditioner is started up, check and modify that
temperature if required using procedure (4.2.1, p22).
4.1
Connecting the air conditioner
When you start the air conditioner, the room temperature is displayed:
-
If the temperature is above the thermostat setting, the air conditioner starts up after a two-minute
delay.
-
If the temperature is below the thermostat setting, the compressor does not start up. Only the fan of
the indoor unit operates.
4.2
Starting up
4.2.1
TEMPERATURE SETTING
The temperature is set on the thermostat:
-
Press the button
for a second till the temperature setting flashes.
-
Use the button
to increase the temperature setting.
-
Use the button
to decrease the temperature setting.
-
When the setting is as required, press the button
to confirm.
Explanations of main symbols on the digital display:
Red
indicator lit on the display = cooling mode engaged (compressor)
Red
indicator lit on the display = high-speed ventilation during cooling mode
Red
indicator lit and message “DF” on the display = defrosting mode in progress
Red
indicator lit on the display = heating mode engaged (resistor)