background image

VERSION 3 

 

  04/01/2021 

I

NSTALLATION AND 

U

SAGE 

G

UIDE   

WINESP40CAPRO 

 

Page 7

 

EVAPORATEUR 

EVAPORATOR 

Air frais 

Cool air 

 

Benefits of ventilated cooling: 

No frost formation other than on the evaporator. 

Automatic defrosting, leading to maximum refrigeration efficiency. 

More uniform cooling due to the continuous movement of air, no air stratification. 

Air circulation allows a rapid return to the selected temperature.

 

 

Содержание WineSP40CAPRO

Страница 1: ...Instructions for installation and use Keep safe for future reference WineSP40CAPRO INFORMATION PROVIDED ON THE IDENTIFICATION PLATE OF THE DEVICE 1 Model 2 Serial no 3 Date of purchase 04 01 2021 ...

Страница 2: ...VERSION 3 04 01 2021 INSTALLATION AND USAGE GUIDE WINESP40CAPRO Page 2 ...

Страница 3: ...R FLOW 14 3 3 2 EXAMPLES OF ASSEMBLY OF THE INDOOR UNIT 15 3 4 PIPING CONNECTIONS 16 3 5 ADJUSTING THE EXPANSION VALVE 17 3 6 ELECTRICAL CONNECTIONS 18 3 6 1 CONNECTING THE OUTDOOR UNIT 18 3 6 2 CONNECTING THE INDOOR UNIT 19 3 6 3 POWER CONNECTION 19 3 6 4 WIRING DIAGRAM 20 3 7 INSTALLING THE CONDENSATE DRAIN 21 4 STARTING UP THE WINEMASTER AIR CONDITIONER 21 4 1 Connecting the air conditioner 21 ...

Страница 4: ...VERSION 3 04 01 2021 INSTALLATION AND USAGE GUIDE WINESP40CAPRO Page 4 ...

Страница 5: ...your satisfaction and we hope that it will enable you to store and mature your wine in the best possible way for peerless tasting pleasure Because we believe customer satisfaction is our primary goal we would like to make you familiar with your new air conditioner and guide you in how to get the best service from it day after day This manual therefore provides you with the technical information an...

Страница 6: ...ure and volume of the room As a result of power reduction depending on the outdoor temperature the device may lose its capacity to maintain 12 C if the outdoor temperature approaches 40 C The circuit breaker rating must be 16 Amperes If the thermal safety system trips too frequently that may damage the compressor prematurely In any event steps must be taken to prevent the temperature of the discha...

Страница 7: ...is Cool air Benefits of ventilated cooling No frost formation other than on the evaporator Automatic defrosting leading to maximum refrigeration efficiency More uniform cooling due to the continuous movement of air no air stratification Air circulation allows a rapid return to the selected temperature ...

Страница 8: ...APRO Page 8 1 2 OVERALL DIMENSIONS Outdoor unit Distance minimale entre le mur et l unité extérieure Minimum distance between wall and outdoor unit Indoor unit Front view Side view Thermostat housing Front view Side view Connections housing Front view Side view ...

Страница 9: ...ful of noise and its effect on the neighbourhood If the unit is installed in a room Place the unit so that the air intake and discharge are not impeded by any obstacles Make sure the room is adequately ventilated Maximum non permanent temperature in the room 40 C Recommended average temperature in the room 20 C 2 2 INDOOR UNIT The indoor unit must necessarily be installed inside the air conditione...

Страница 10: ...lation The insulating materials should preferably be assembled By fitting the grooves of panels into each other or By gluing the panels to each other GOAL Avoiding the unwanted entry of heat and humidity that could be harmful for regulation Cross section 1 WALL 2 INSULATION 3 FLOOR 4 FINISHED FLOOR 5 CEILING 6 INSULATED DOOR 2 To indoor unit Cable length 2m To outdoor unit Cable not supplied To th...

Страница 11: ...ystyrene mm λ 0 030 W m 1 K 1 Thickness of polyurethane mm λ 0 025 W m 1 K 1 4 20 10 10 8 30 20 20 12 50 30 30 16 60 40 40 20 80 50 50 24 90 60 50 28 100 70 60 32 120 80 70 36 140 90 80 40 150 100 90 If glazed walls are used the coefficient Ug of the glazing must be no more than 1 0 W m K Further the glazed surface may not represent more than 50 of the total surface of the walls of the air conditi...

Страница 12: ...strong panel on the top Insulation lined with wood chipboard approximately 15 mm thick or any other appropriate covering e g screed and slab 2 6 2 DOOR It helps to keep the insulation continuous Two solutions are possible Insulating the existing door with insulation of the same type as on the walls of the room and inserting a seal e g in foam between the door leaf and frame over the entire perimet...

Страница 13: ...and 3 8 copper pipes for refrigeration connections Fasteners and tools for fastening the outdoor unit 3 2 PUTTING IN PLACE THE OUTDOOR UNIT 3 2 1 INSTALLATION Step 1 Mark out and drill the fastening holes as indicated Drilling diameter 12 mm max Step 2 Unfold the brackets Step 3 Fasten the brackets with the appropriate fasteners Step 4 Place the air conditioner on the brackets Step 5 Screw the fou...

Страница 14: ...e The intake and discharge openings must not be obstructed even in part The discharge and intake must be separated in order to avoid taking back discharged air even in part as a test the intake temperature must be identical to the temperature in the room when the device is cooling it Make the electrical connections before fastening the indoor unit to the ceiling if permitted by the cable lengths s...

Страница 15: ...VERSION 3 04 01 2021 INSTALLATION AND USAGE GUIDE WINESP40CAPRO Page 15 3 3 2 EXAMPLES OF ASSEMBLY OF THE INDOOR UNIT Installation with separating partitions Installation without separating partition ...

Страница 16: ... 10 metres The number of bends per connection may not exceed 10 In order to have the right quantity of refrigerant in the device refer to the curve below for the refrigerant charge When satisfactory operation is obtained loosen the connecting valves fully before disconnecting the piping fittings The connections can then be disconnected and plugs put back on the valves 622 641 660 678 697 715 734 7...

Страница 17: ...n valve fully turn the screwdriver clockwise Check the position of the tip of the screwdriver to give it the right number of turns for correct expansion valve adjustment Step 4 For R449 OPEN default adjustment the expansion valve by 2 TURNS turn the screwdriver anticlockwise FOR R404A OPEN the expansion valve by 4 TURNS turn the screwdriver anticlockwise Step 1 Take off the cover to reach the expa...

Страница 18: ... it may only be replaced by the manufacturer its after sales department or a party with similar qualification 3 6 1 CONNECTING THE OUTDOOR UNIT Step 1 Unscrew and remove the electrical access plate of the outdoor unit Step 2 Connect the connections housing and the outdoor unit through the cable tie with the 4G1 5 cord not supplied as shown in the wiring diagram see section 3 6 4 p 20 Step 3 Close ...

Страница 19: ...ECTION The connections housing must be connected to a single phase electricity line protected by a 230V 16A two pole circuit breaker Step 1 Unscrew and remove the front cover Step 2 Route the cord through the cable tie Step 3 Connect the cord as indicated in the wiring diagram see section 3 6 4 p 20 Step 4 Close the cover ...

Страница 20: ...CAPRO Page 20 3 6 4 WIRING DIAGRAM PRESSURE ACTUATED SPEED CONTROLLER DO NOT connect the white cable FAN COMPRESSOR LP MINIATURE PRESSURE SWITCH HP MINIATURE PRESSURE SWITCH HEATING BELT GROUND RIVET Thermostat Probe 1 Yellow 3 Green 4 L Grey 5 Pink 6 L Brown ...

Страница 21: ...ner When you start the air conditioner the room temperature is displayed If the temperature is above the thermostat setting the air conditioner starts up after a two minute delay If the temperature is below the thermostat setting the compressor does not start up Only the fan of the indoor unit operates 4 2 Starting up 4 2 1 TEMPERATURE SETTING The temperature is set on the thermostat Press the but...

Страница 22: ...mode engaged resistor 4 2 2 STANDBY MODE Putting the air conditioner on standby keep button 1 pressed in for 3 seconds The compressor will stop and the fan will switch to slow speed The thermostat will alternately display OFF and the cellar temperature To exit the standby mode keep button 1 pressed in for 3 seconds once again The thermostat will display ON for 1 second 4 2 3 AUTOMATIC DEFROSTING T...

Страница 23: ...has a washable reusable filter Unscrew the two plastic screws 1 Take off the filter cover 2 Take out the filter 3 Wash the filter with hot water Once the filter is clean and drained put it back in place and close the opening Regularly inspect and clean the filter Fouled filter air conditioner damaged Regularly inspect and clean the openings Opening clogged air conditioner damaged 5 2 CONDENSATE DR...

Страница 24: ...ter fouled failure of the fan of the outdoor unit room in which the outdoor unit is located improperly ventilated presence of obstacles that impede the air flow etc If a safety system trips you only need to reset the device after first removing the cause see below In all other cases a technician will need to be called in The low pressure safety device protects the compressor in the event of certai...

Страница 25: ...ply if the purchase invoice or a copy thereof can be produced 6 4 GUARANTEE EXCLUSIONS AND LIMITS The guarantee shall not apply in the following cases The insulation of the air conditioned room or installation are not in accordance with this guide The problem is due to negligence improper maintenance faulty or inappropriate use of the WINEMASTER air conditioner particularly if the filters are foul...

Отзывы: