![Wine Guardian WG 100 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/wine-guardian/wg-100/wg-100_installation-operation-and-maintenance-manual_986039051.webp)
47
Humidity too high when the unit is not running
Possible Cause
Solution
Unit needs to run to dehumidify
Run unit. Seal openings around doors (gasket and
sweep)
Humidity too high when unit is running and cooling
Possible Cause
Solution
Too much moisture in cellar Poor vapor barrier installation
Humidifier malfunction refer to
the humidifier instructions.
Add dehumidifier to surrounding space
Other Miscellaneous Problems
Unit operates but the power switch light is not ON
Possible Cause
Solution
Bulb is burned out
Replace bulb
Unit is leaking water
Possible Cause
Solution
Trap plugged Clean trap
Condensate pan plugged
Remove blockage and clean
Unit not level
Level with shims
Unit is running properly, but the sound of the unit is objectionable
Possible Cause
Solution
Noise is from airflow Redirect airflow
Add baffles
Add insulated ductwork
Noise is from unit
Add sound baffle between unit and occupied
space