29
Plug the system into the wall outlet. Gently pull on the plug to make sure it is
tight.
Electrical Plug Configuration 60Hz Models Only
To comply with the UL STD 484 this system contains a factory supplied LCDI
(leakage current detection interrupter) power cord, which specifies that single
phase portable air conditioning units contain a protection device to reduce the risk
of an arc fault occurring in the power cord. These provide a reliable way to prevent
the risk of fire due to a damaged power cord. They feature electronic detection to
automatically cut off power to the unit when a current leakage condition is detected
in the systems power cord.
Electrical Plug Configuration 50Hz Models Only
This is the configuration of the factory supplied plug for European applications.
Alterations to this plug for alternative power sources would require factory
approval. LCDI (leakage current detection interrupter) power cord, which specifies
that single phase portable air conditioning units contain a protection device to
reduce the risk of an arc fault occurring in the power cord. These provide a reliable
way to prevent the risk of fire due to a damaged power cord. They feature
electronic detection to automatically cut off power to the unit when a current leakage condition is detected
in the systems power cord.
Once power is shut off, the device will not be able to be reset until the unsafe current leakage situation is
resolve. Power is restored by the “reset” button on the cord’s power head
.