background image

 

CLEANING & MAINTENANCE

10

OPERATION & FEATURES 

1. 

EASY ACCESS CONTROL SWITCH (from left to right) 

a.  Button 1 – ON / OFF 

b.  Button 2 – Low Speed  

c.  Button 3 – Medium Speed  

d.  Button 4 – High Speed 

e.  Button 5 – Light 

 

2. 

ALUMINUM FILTERS 

a.  (1) Aluminum filter (30” model) 

b.  (2) Aluminum filters (36” / 42” model) 

 

3. 

CHARCOAL FILTERS 

**DO NOT WASH CHARCOAL FILTERS! IT WILL DISSOLVE!!** 

a.  Replace safety filter with charcoal filter. 

(Fig. 3a)

 

 

b.  Installation is complete after the charcoal filter is secured in place. 

c.  When to replace a charcoal filter will depend on: 

i.  How often you cook. 

ii.  How long you cook. 

iii.  Types of food you cook

 

CLEANING & MAINTENANCE

11

CLEANING & MAINTENANCE 

WARNING!!! 

 To prevent the possibility of a fire and explosion, do not use 

flammable liquids or solvents to clean the unit or any of its parts. 

 Check to make sure all power sources are disconnected 

before servicing or taking unit apart for cleaning. 

 Please thoroughly clean the unit weekly as stainless steel 

can rust under certain condition or by improper cleaning. 

1. 

RANGE HOOD 

a.  Use household cleaner to remove grease or dirt from the outer shell of the 

unit. Spray on wiping cloth or sponge and wipe in the direction of the grain 

to avoid scratching the unit. (DO NOT SPRAY DIRECTLY ONTO UNIT) 

b.  Clean the inner working of the unit periodically to avoid grease build-up. 

c.  Do not open control switch panel while the hood is connected to power. 

d.  Use stainless steel cleaner to bring back the luster of the unit. 

 

2. 

ALUMINUM FILTERS 

a.  Remove aluminum filters from unit and place in warm soapy water.  

b.  Clean the filters regularly to maintain efficient suction power. 

c.  Do not drop filters. 

d.  Let it soak thoroughly and then clean it with a wiping cloth or sponge. 

e.  Filters may also be cleaned using residential dishwasher.

Содержание HI30SS

Страница 1: ...VING CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED This unit was designed for indoor residential use only DO NOT USE OVER A WOOD GRILL OR MOUNT IN OUTDOOR ENVIRONMENT ISLAND SERIES 1 TABLE OF CONTENTS Table of Contents Safety Information 2 3 Content Checklist 4 Measurements 5 Preparation 6 Installation 7 8 Installation Diagram 9 Operation Features 10 Cleaning Maintenance 11 Troubleshooti...

Страница 2: ... reduce the risk of fire use only metal ductwork CAUTION FOR GENERAL VENTILATING USE ONLY DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPOR 3 SAFETY INFORMATION TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE Regardless of heat level never leave any surface materials unattended while operating an open flame Always turn hood ...

Страница 3: ...h 1 Screw packet i 1 Duct cover support bracket 2 CONTENTS NOT INCLUDED a HILDC Long duct cover b HISDC Special duct cover c HIBF Baffle filter d HIDK Ductless kit e HICF Charcoal filter f HICFMR CFM reducer g 7 Aluminum or metal piping h PC16 Power Cord 3 TOOLS REQUIRED NOT INCLUDED a Safety gloves b Safety glasses c Electric drill w starter bit d Utility knife e Spirit level f Measuring tape g W...

Страница 4: ... 1a and 1b on page 5 for measurements INSTALLATION 7 INSTALLATION 1 STANDARD INSTALLATION a Make sure all preparation steps are completed b Determine your ceiling height to see if you need an extension i Hood unit with glass height 3 1 4 30 model only ii Hood unit with glass height 4 1 4 36 model only iii Hood unit with glass height 6 42 model only iv Standard DC height 16 1 2 lower 22 7 8 upper v...

Страница 5: ...e unit and seal the connection point with aluminum tape Be sure it is secure with no opening or gaps d Connect piping to the outlet of the hood e Installation is complete when hood is securely in place 4 DUCTLESS INSTALLATION OPTIONAL a AFTER COMPLETING Step A E of STANDARD INSTALLATION b Remove the HIDK ductless kit and inspect for any sign of defect or damage ie dents broken inlet c Attach the d...

Страница 6: ... Check to make sure all power sources are disconnected before servicing or taking unit apart for cleaning Please thoroughly clean the unit weekly as stainless steel can rust under certain condition or by improper cleaning 1 RANGE HOOD a Use household cleaner to remove grease or dirt from the outer shell of the unit Spray on wiping cloth or sponge and wipe in the direction of the grain to avoid scr...

Страница 7: ...levels not working correctly 1 Ensure all Wiring from Control Switch and Top Junction Box are correctly connected 2 Complete Capacitor replacement may be required Unit lacking smoke intake 1 Check ducting for foreign object 2 Ensure the ducting is properly sealed 3 Clean filters to increase airflow Unit showing no power indication 1 Ensure power source is working properly 2 Ensure all Wiring from ...

Страница 8: ...purchased the unit for service Windster Hoods Inc will attempt to repair malfunctioning units prior to shipping a replacement In the case that a unit cannot be repaired and must be replaced Windster Hoods Inc will not be held liable for removal installation fees of the malfunctioning replacement unit WARRANTY CONTACT US 15 WHAT IS NOT COVERED BY MANUFACTURE WARRANTY 1 Damages resulting from any of...