background image

MACHINE OPERATION

STRIDE2 36V (SS)  98745  11/08/99

3-10

TO BEGIN SCRUBBING

When operating the machine around people, pay
close attention for unexpected movement. Use
extra caution around children.

Flammable liquids and/or reactive metals can
cause explosions or fire! Do not pick up.

1.

Turn the machine power on.

2. 

Lower the squeegee.

3. 

Turn the vacuum on.

4. 

Lower the scrub brushes to the floor.

5. 

Turn the scrub brushes on (brushes will start
when machine is propelled).

6. 

Drive machine forward to begin scrubbing.

NOTE:  Shut machine off immediately if water or
foam is expelled from the machine.

7.

Adjust the speed of the machine, solution flow
and scrub brush pressure as necessary.

NOTE:  Once solution flow rate is set it is not
necessary to shut off solution when stopping
scrubbing.  Solution flow is automatically shut off
when brush motors stop.  When brush motors are
activated, flow automatically resumes.

TO STOP SCRUBBING

1. 

Release the directional control lever.

2. 

Turn the scrub brushes off.

3. 

Raise the scrub brushes.

4. 

Raise the squeegee.

5. 

Turn the vacuum off.

6. 

Turn the machine power off.

DOUBLE SCRUB

Floors which are heavily soiled or have thick
accumulations of floor finish may not clean
sufficiently with one pass. In these cases it will be
necessary to double scrub.
To double scrub, make the first pass over the
surface being cleaned with the squeegee up,
vacuum off, the solution on, and brushes down. This
allows the

 

solution to stay in contact with the soil

while loosening the surface accumulation with the
brushes. Allow time for the first application to stay in
contact with the floor. Length of time between the

first and second pass depends on amount of
accumulation and the type of chemical being used.
A second scrubbing with the squeegee down and
again the solution and brushes on will further loosen
soil. The additional application of solution will further
assist the difficult cleaning job.

FOR SAFETY:  

When using machine, go slow on

inclines and slippery services.

EMPTYING AND CLEANING TANKS

1. 

Park the machine next to a floor drain.  Drain
hose is on left rear corner of the machine.

2. 

Turn the machine power off and set parking
brake, if your machine is equipped with this
option.

SOLUTION TANK

1. 

Unhook the small drain hose from the retainer.
Unscrew T-handle on plug enough to loosen
plug, then lower hose in direction of the drain.
Slowly remove plug from drain hose.

2. 

Remove the solution tank cover.

3. 

Flush the solution tank out with clean water and
run several gallons of clean water through
systems. Do not use water hotter than 140°F
(60°C) to clean tank. Damage may occur.

NOTE:  Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.

4. 

Replace the drain plug and secure drain hose in
bracket.

RECOVERY TANK

1.

Unhook the large drain hose from the retainer.
Unscrew the T-handle on plug enough to loosen
plug, then lower hose in direction of the drain.
Do not stand in front of end of hose. Recovered
solution will come out with force. Slowly remove
plug from drain hose.

2.

Raise solution tank to access recovery tank.
Make sure the support arm is fully engaged.
Flush the recovery tank out with clean water. Do
not use water hotter than 140°F (60°C) to clean
tank. Damage may occur.

3. 

Clean off the float switch and check for free
movement of float. The float switch is located in
the front of the recovery tank.

4. 

Replace

 

the drain plug and secure drain hose in

bracket.

5. 

If machine is to be stored, leave solution tank in
raised position.

!

CAUTION

!

WARNING

Содержание STRIDE 2

Страница 1: ...Read these instructions before using the machine MODELS QQSS28 QSS28 QQSS34 QSS34 Beginning with Serial 1000034672 Operating Instructions 98745 12 28 01 W WALK BEHIND SCRUBBER IPX4...

Страница 2: ..._____ OVERVIEW The Stride2 SS is a battery powered self propelled hard floor scrubber intended for commercial use The appliance applies a cleaning solution onto a hard floor scrubs the floor with brus...

Страница 3: ...e or Rotate Rear Squeegee Blade 4 4 Replace or Rotate Front Squeegee Blade 4 4 Adjusting Squeegee Pitch 4 5 Adjusting Rear Deflection 4 5 Service Schedule 4 6 Machine Troubleshooting 4 7 GROUP PARTS L...

Страница 4: ...Skirt Squeegee Blade Brush Head Options Service Schedule The PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of infor...

Страница 5: ...tories shops and offices for more than normal housekeeping purposes Maintenance and repairs must be done by qualified personnel If foam or liquid comes out of machine switch off immediately Disconnect...

Страница 6: ...this information carefully Know when these conditions can exist Locate all safety devices on the machine Please take the necessary steps to train the machine operating personnel FOR SAFETY DO NOT OPER...

Страница 7: ...the labels become illegible promptly replace them SAFETY DECAL 81494 MANUAL DECAL 50776 BATTERY CAUTION 80885 2 GRADE DECAL 50926 MANUAL DECAL 50776 SAFETY DECAL 81505 CAUTION Explosive Gas is Given...

Страница 8: ...g Scrub brush speed 200 rpm Tires 2 x 12 in 30 5 cm pneumatic non marking standard Casters 2 X 4 in 10 2 cm polyurethane solid non marking Foundation Pressure at recommended tire psi 38 lbs in 2 267 k...

Страница 9: ...in 86 cm scrub head 34 in 86 cm SPECIAL NOTES The sound pressure level at the operator s ear was measured to be 68 dBA This was a nearfield broad band measurement taken in a typical industrial environ...

Страница 10: ...ow the scrub brushes to follow irregularities and changes in the floor without loosing contact with floor The self adjusting scrub deck skirt controls the cleaning solution on the floor so that the sq...

Страница 11: ...Front Cover 4 Recovery Tank 5 Recovery Tank Drain Hose 6 Scrub Head 7 Scrub Brush Access Cover Disk 8 Solution Tank 9 Solution Tank Cover 10 Solution Tank Drain Hose 11 Solution Strainer 12 Solution...

Страница 12: ...t Lever 7 Recovery Tank Full Indicator 8 Key Switch 9 Direction Control Lever 10 Speed Control Knob 11 Battery Charge Level Indicator 12 Emergency Shut Off Switch Optional 13 Hour Meter Optional 14 Ci...

Страница 13: ...INDICATOR The brush pressure indicator corresponds to the amp draw of the scrub brush motors to tell how hard the motors are working The green zone indicates proper operating brush pressure The red z...

Страница 14: ...icate a full charge It will also indicate a full charge if the batteries are disconnected then reconnected After a few minutes of operation the meter will give the correct charge level 12 EMERGENCY SH...

Страница 15: ...decrease squeegee blade deflection at the ends turn knob clockwise 17 SQUEEGEE DEFLECTION ADJUSTMENT KNOBS Adjusts the deflection along the entire length of the squeegee To increase squeegee blade de...

Страница 16: ...e if your machine is equipped with this option 3 Remove solution tank cover 4 Fill the solution tank with clean water leaving enough room for the required amount of cleaning solution The solution tank...

Страница 17: ...ends on amount of accumulation and the type of chemical being used A second scrubbing with the squeegee down and again the solution and brushes on will further loosen soil The additional application o...

Страница 18: ...ye protection and protective clothing when working with batteries Charge batteries in a well ventilated area BATTERY MAINTENANCE 1 When cleaning the batteries use a solution of baking soda and water D...

Страница 19: ...Unplug the battery connector from the machine FOR SAFETY When charging connect the charger to the batteries before connecting the charger to the AC wall outlet Never connect the charger to the AC wal...

Страница 20: ...n a variety of applications on coated or uncoated surfaces White Pads Polishing are used for dry polishing to achieve a high gloss appearance or surface washing on highly polished or burnished floors...

Страница 21: ...controls the pitch adjustment The second adjustment is the deflection Knobs on each end of the squeegee control the Standard Squeegee Assembly adjustment A color coded slide bar controls the Smart Squ...

Страница 22: ...lection of the squeegee blade at the ends loosen plastic knob near the squeegee center To increase the deflection at the ends of the squeegee assembly tighten plastic knob 5 Check the deflection of th...

Страница 23: ...y Charge the batteries Remove the pad drivers brushes Check the brushes pads for damage and or wear Clean squeegee blades Clean recovery tank shut off screen Check battery cells w hydrometer Check sol...

Страница 24: ...s not run or runs slowly Recovery tank full Drain recovery tank Recovery tank float switch dirty Clean float switch Circuit breaker tripped Reset circuit breaker Loose connection Check motor wires and...

Страница 25: ...Vent hole in solution tank lid obstructed Clear obstruction from vent hole No power to machine Battery disconnected Check all battery cable connections Emergency shut off activated Reset Battery conn...

Отзывы: