background image

PROBLEM 

No 

power. 

Vacuum motor 

does not run. 

Brush motor 

does 

not 

run. 

Solution light 
does not work. 

Battery charge 
level Indicator 

lights. 

PROBABLE CAUSE 

Circuit breaker tripped. 

Battery cables corroded 

at battery terminals. 

Faulty main switch. 

Faulty safety  override 
micro switch. 

Faulty solenoid. 

Circuit breaker tripped. 

Loose connections. 

Faulty 

circuit 

breaker. 

Faulty 

switch. 

Motor brushes worn. 

Circuit breaker tripped. 

Loose connection. 

Faulty solenoid. 

Faulty drive motor. 

Faulty circuit  breaker. 

Loose connections. 

Faulty solution light. 
Light stay on with 
solution lever in 
“OFF”  position. 

No light are on with 
main switch on. 

Loose connections. 

CORRECTIVE ACTION 

Reset brush motor circuit breaker 

(50 amp). 

1. Clean battery cable clamps and battery terminals. 

2.  Check voltage at points A and 

Voltage should be 22/26 VDC. 

1. 

Check voltage at points A and C.  Voltage should be 22/26 VDC. 

2.  Turn  main  switch  on  and check  voltage  at  points A  and  D.  Voltage  should  be 

With main switch 

“ON”  check voltage at points A and 

E and A and F. Voltage should 

be 22/26  VDC. 

If  no voltage  at  A and  F  remove leads and check  micro switch for 

continuity.  Should be continuity 

in 

normal position and no continuity  when switch 

lever is activated. 

With main switch on (solenoid energized) check voltage at points 

A  and G 

voltage 

should be 22/26 VDC. 

I f  no voltage replace solenoid. 

Reset 

motor circuit  breaker. 

Check  motor  lead  connections  at  terminal  block  and 

connector  near 

motor.  Keep all connections  tight. 

With  main switch  on  check  voltage  at  points A  and  H and A  and  I.  If  no voltage, 
check continuity of  circuit breaker. Replace as needed. 

Remove leads and check switch for continuity. Replace as needed. 

Check  motor  brushes.  Replace when  worn  to 

Check 

motor  by  securing 

motor and applying 24 VDC to motor leads. 

No load amp draw  of  motor should be 

15 

amp. 

Reset 

(50 amp) brush motor circuit breaker. 

Check motor leads at terminal block connection (located under right hand lower 
side panel) tighten set screws as needed. 

With main switch on check ouput voltage at points A and 

G. Voltage should be 

22/26 VDC. 
Check  motor  brushes 

replace when  worn  to 

With  batteries  fully  charged 

and motor secured, apply battery voltage direct to motor. 

No load amp draw 

of  motor 

should be 12 to 13 amps. 

Reset (6 amp) battery circuit breaker. 

Check for loose electrical connections at terminal block, solution switch,  and 
solution light. 

Remove light and apply direct  battery voltage (24  VDC) to light.  Replace light as needed. 

Adjust solution light switch. 

22/26 VDC. 

If no voltage remove leads and check switch for continuity, 

Check (6 amp) battery circuit breaker. Reset 

i f  tripped. 

1. 

Check electrical connections  at circuit breaker. 

2.  Check voltage at inline connector at PC Board. Should be 22/26 VDC. 

17 

Содержание PowerTec20

Страница 1: ......

Страница 2: ...trical components of the machine dry Lead acid batteries generate gases which can cause an explosion Keep sparks and flames away from the batteries Charge the batteries only in a well ventilated area...

Страница 3: ...Controls flow of cleaning solution to floor Light ON indicates solution valve is open Indicates charge condition of batteries 4 green lights full charge approximately 4 112 hours run time 1 green ligh...

Страница 4: ...TE Dis connect the AC power cord from the wall receptacle before removing the DC charger plug from machine 2 Check water level In batteries Add distilled water as needed 3 Attach brush or drive pad to...

Страница 5: ...sure battery charger is dlscon nected 3 Make sure all switches are OFF 4 Remove batteries as required or dlscon nect main battery leads from batteries when making repairs to electrical system VACUUM...

Страница 6: ...er bearing from hub use a piece of 314 dia tube to drive out bearing SQUEEQEEASSEMBLY To remove squeegee assembly 1 Depress pedal to raise squeegee 2 Pull retaining pin from locator stud 3 Push down o...

Страница 7: ...lt when the traverse handle is in the neutral position 1 Start the brush motor and lower the brush slowly to the floor When the rear of the brush A touches the floor the To adjust clearance A Remove l...

Страница 8: ...VAC BATTERY TANK 7 VAC BATTERY TANK REV PARTNO mnitvion 32 9 70280 Stud 1 4 Turn Fastener 10 70076 Scr 10 32 x 1 FHMS 11 51074 Lug Shroud Mounting 12 48012 Knob 5 16 18 8...

Страница 9: ...1 7 AI 1 6 9...

Страница 10: ...MAINFRAMEWITANKS 38 I 34 37 36 35 39 41 i o 1 3 14 1 46...

Страница 11: ...SQUEEGEE w ARM 59 69 21 1 I __ 11...

Страница 12: ...oke PT 20 Drive Linkage 24 57112 Nut 5 16 18 Flange 25 57104 Nut 10 32w Star Washer 26 67122 Rod Drive Linkage 27 14509 Bracket RH Drive Handle Mtg 28 62190 Plate PT 20 Support 29 62211 Plate Drive Ha...

Страница 13: ...48 4 9 50...

Страница 14: ...14 2 1 IAL 39...

Страница 15: ...PT 20 LABELS PART NO DESCRIPTION LOCATION I inside cover On handle I50378 Instruction Card I I9387 Maintenance Under hood I 15...

Страница 16: ...19 Spring PT 20 Brush Lock 63A 02095 Brush PT 20 Nylon 638 02096 Brush PT 20 Polypro 63C 02097 Brush PT 20 Extra Aggressive 630 02098 Pad Driver PT 20 64 59020 0 Ring 4125 65 57133 Nut M24 x 2 Lock 66...

Страница 17: ...s shown on Page 16 in the service manual Retain this notice in your manual for reference when ordering replacement parts 1 Key 44 Changed to rod with lock nuts replacing the snap rings 2 Keys 1 2 3 4...

Страница 18: ...A and G voltage should be 22 26 VDC If no voltage replace solenoid Reset vac motor circuit breaker Check motor lead connections at terminal block and inline connector near vac motor Keep all connecti...

Отзывы: