background image

17

Maintenance

Troubleshooting

PROBLEM

CAUSE

SOLUTION

Loss of Power

Unit not plugged in

Connect unit to 3 prong grounded outlet.

Dead electrical circuit

Check building circuit breaker or fuse box.

Faulty power cord

Replace 

Electrical shock

Receptacle not grounded

Contact an electrician to check building's wiring

Internal wiring problem

Have a trained service technician check 
machine's wiring

Vac motor speed 
varies or doesn't run

Vacuum circuit breaker tripped

Reset Breaker

Faulty vacuum motor

Replace

Faulty switch

Replace

Loss of vacuum

Loose vacuum dome

Center and seal dome over tank

Crack in dome or poor joint

Replace or repair using acrylic plastic cement 
only

Lint or dirt clogging vacuum screen

With power off clean screen

Loose cuffs on vacuum hose

Tighten cuffs turning counterclockwise

Vac motor seals leaking

Replace

Floor tool vac chamber clogged

Wash out with hose.  Pick lint out with a wire

Vacuum hose damaged

Replace

Recovery tank full / Float ball stuck in 
the up position

Turn off power, drain recovery tank.

Pump runs no solution

Pump inlet screen plugged

Clean inlet screen

Pump not primed

Press trigger to open valve on cleaning wand to 
relieve air lock.

Internal or external solution line 
damaged and leaking

Replace

Pump runs, loss of 
pressure

Internal pump components wearing out Replace, see pump kit components

Pump will not run

Faulty switch

Replace

Loose wiring

Repair or replace

Solution hose fitting 
hard to connect

Corrosion on fittings. 

Clean with steel wool. Soak in acetic acid (white 
vinegar). Lubricate lightly with silicone base 
lubricant.

Carpet not getting 
clean

Severe soil conditions

Make several passes at right angles to each 
other.  Use a pre-spray.

Carpet too wet

Over saturation

Make several passes without spray

Carpet browning

Leaving carpet too wet

Check for loss of vac pressure

Too much chemical

Check label for correct solution concentration

Solution not flowing 
properly

Solution hose connection

Check for positive connection

Faulty pump

Repair or replace

Faulty floor tool valve / Nozzle

Repair or replace

Faulty pump switch

Repair

86399190   Operators Manual - Dominator 150 psi 17 gallon

Содержание Dominator 17 NMWU2215N

Страница 1: ...86399190 A 01 02 15 Dominator 150 PSI 17 gallon Extractor Operating Instructions ENG MODELS NMWU2215N 10066700 From Serial Number Ref No 1 See Serial number page or call manufacturer ...

Страница 2: ...the product To register your product go to http warranty karcherna com For customer assistance 1 800 444 7654 2 86399190 Operators Manual Dominator 150 psi 17 gallon Machine Data Label Overview The Dominator is an electric powered carpet extractor intended for commercial use This appliance applies a cleaning solution to the carpet and then vacuums the soiled water back into the recovery tank ...

Страница 3: ...ounding Instructions 8 Operations Technical Specifications 9 Controls 10 Machine Operation 11 Chemicals 11 Pre Run Inspection 12 Equipment Set up 12 Cleaning 12 Maintenance Periodic Maintenance 14 Daily Regular Maintenance 14 Vacuum Motor Replacement 15 Solution Pump Replacement 16 Troubleshooting 17 Suggested Spare Parts 18 86399190 Operators Manual Dominator 150 psi 17 gallon ...

Страница 4: ... unsafe practices of the machine Levels of hazards are identified that could result in product damage personal injury or severe injury resulting in death The OPERATIONS section is to familiarize the operator with the operation and function of the machine The MAINTENANCE section contains preventive main tenance to keep the machine and its components in good working condition They are listed in this...

Страница 5: ...rd use as a handle close a door on cord or pull cord around sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces Do not unplug machine by pulling on cord To unplug grasp the electrical plug not the electrical cord Do not handle the electrical plug or machine with wet hands Do not operate the machine with any openings blocked Keep openings free of debris that may ...

Страница 6: ... damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentially dangerous conditions to the operator or the equip ment Read this information carefully Know when these conditions can exist Locate all safety devices on the machine Please take the necessary steps to train the machine operating personnel F...

Страница 7: ...y Safety Labels NOTE These drawings indicate the location of safety labels on the machine If at any time the labels become illegible promptly replace them 86399190 Operators Manual Dominator 150 psi 17 gallon ...

Страница 8: ...lt circuit and has a grounded plug that looks like the plug in Fig A A temporary adapter that looks like the adapter in Fig C may be used to connect this plug to a 2 pole receptacle as shown in Fig B if a properly grounded outlet is not available The temporary adapter should be used only until a properly grounded outlet Fig A can be installed by a qualified electrician The green colored rigid ear ...

Страница 9: ...ion or instruction concerning use of the appliance by a person responsible for their safety ITEM MEASURE Electrical 115 Volt 60 hz 15A Solution Pump 150 psi Solution Capacity 17 Gal Recovery Capacity 14 Gal Height 43 inches Length 32 5 inches Width 22 5 inches Vacuum Motor Dual 2 Stage Weight Empty 120lbs Weight Full Solution 261 lbs Power cord 1 X 25 feet Height Length Width 86399190 Operators Ma...

Страница 10: ...m Accessory Tool Hook up 2 Solution Pump Switch 3 Vacuum 1 Switch 4 Vacuum 2 Switch 5 Breaker for Vacuum 2 6 Breaker for Vacuum 1 7 Solution Accessory Tool Hook up 86399190 Operators Manual Dominator 150 psi 17 gallon 6 7 5 4 3 2 1 ...

Страница 11: ...type used for carpet cleaning Chemicals Suitable Chemicals Alkalis Detergents Hydroxides Soaps Vinegar Non Compatible Aldehydes Aromatics Hydrocarbons SP Butyls Carbon Tetrachloride Clorox Chlorinated Bleaches Chlorinated Hydrocarbons Lysol Methyl Ethel Ketone MEK Perchorethylene perc Phenolics Trichlorethylene D Limonene Registered Trademark Only use chemicals approved for use with this machine U...

Страница 12: ...n tank 6 Turn pump and vacuum switch es to the on position Cleaning Always use defoamer if foaming occurs Foam will suspend large particles that may damage vacuum s as well as allow liquid into the vacuum motor s without activating the float shutoff 1 Prior to cleaning make certain that the nozzle is functioning properly a To check hold the wand about one foot above the surface to be cleaned and o...

Страница 13: ...13 Notes 86399190 Operators Manual Dominator 150 psi 17 gallon ...

Страница 14: ...pect and clean filter screen in solution tank 3 Flush pumping system with 1 to 2 gallons of clean water 4 After each use rinse tank with fresh water Period ically inspect the recovery tank and decontaminate if necessary using a Hospital Grade Virucide or a 10 1 bleach to water solution Waste water should be disposed of properly Do not allow machine to freeze SERVICE SCHEDULE DAILY WEEKLY QUARTERLY...

Страница 15: ...mm Carbon Brushes End Cap WARNING The green ground wire must be attached for safe operation See wiring diagram If armature commutator is grooved extremely pitted or not concentric the motor will need to be replaced or sent to a qualified service center Important These brushes wear quicker as the length shortens due to increased heat Spring inside brush housing will damage motor if brushes are allo...

Страница 16: ... Pump Replacement Only qualified maintenance personnel are to perform the following repairs PUMP REPLACEMENT KITS 150 PSI 86399190 Operators Manual Dominator 150 psi 17 gallon BYPASS VALVE KIT 86258830 DIAPHRAGM KIT 86235100 ...

Страница 17: ...ball stuck in the up position Turn off power drain recovery tank Pump runs no solution Pump inlet screen plugged Clean inlet screen Pump not primed Press trigger to open valve on cleaning wand to relieve air lock Internal or external solution line damaged and leaking Replace Pump runs loss of pressure Internal pump components wearing out Replace see pump kit components Pump will not run Faulty swi...

Страница 18: ...ual Dominator 150 psi 17 gallon 86300070 HUBCAP 86135320 BRUSH SET VACUUM MOTOR 86258830 BYPASS VALVE KIT 86235100 DIAPHRAGM KIT PUMP 86309790 WHEEL 86001660 HUBCAP SHAFT 86010730 WASHER 86199430 CASTER 86007970 STRAINER SOLUTION 86344490 DECK PLATE ...

Страница 19: ...19 Notes 86399190 Operators Manual Dominator 150 psi 17 gallon ...

Отзывы: