31
Maintenance
11. Vacuum Motor
(Refer to the Vacuum Group in the parts section of
manual)
Do not use a pressure washer to clean around the
vacuum motors. Use tap pressure only. Care must
be taken so that water is not directed into vacuum
motor air intakes.
Ne pas utiliser un jet d’eau à forte pression pour
laver autour des moteurs d’aspiration. N’utiliser
que la pression de l’eau du robinet. Veiller à ne pas
diriger l’eau sur les prises d’air des moteurs d’aspi-
ration.
Changing Vacuum Motor
1.
Disconnect batteries from machine.
2.
Remove front cover.
3.
Disconnect electrical connector to the vacuum
motor.
4.
Loosen clamp and disconnect hose from vacuum
intake.
5.
Remove vacuum motor mounting bracket bolts.
6.
Remove vacuum motor from mounting bracket.
7.
Reverse steps to install.
86400370 Manual Operators - EURO 24V Standard
3
8
[9.5mm]
Vacuum Motor Carbon Brushes
Carbon
Brushes
End Cap
If armature commutator is grooved, extremely pitted or not
concentric, the motor will need to be replaced or sent to a
qualified service center.
Important:
These brushes wear quicker as the length shortens due to
increased heat. Spring inside brush housing will damage
motor if brushes are allowed to wear away completely.
Periodically check the length of the carbon brushes. Replace
both carbon brushes when either is less than 3/8" (9.5mm)