background image

 

 

1.  EN 

1.1 

Description  

The weather station is a robust unit without any moving parts, it measures temperature, precipitation, relative humidity, wind speed 
and direction. Furthermore, is it equipped with a GPS antenna for e.g., time registration / synchronization.  
The weather station is supplied with a 20m connection cable incl. connection plug, which must be used. 
The weather station is used together with WindowMaster MotorControllers WCC 3x0 Plus ver. x4 and smoke panels WSC 3x0 Plus 
ver. E4 and WSC 5xx ver. E2.  
 
WOW 600 is a customized version of the GMX600 from Gill Instruments.   
Instructions for the GMX600 can be found on Gill Instruments home page

http://gillinstruments.com/

. 

 
WOW 600 does not detect snow, if snow detection is desired, the purchase of WLA 331 is recommended. For connection of WLA 
331, please refer to the WLA 331 instruction manual or the instruction manual for the control panel.  
 
The supplied cable and connector is a customized version and is mandatory for the WOW 600 to function on WindowMaster 
MotorControllers / smoke panels. 

1.2 

Mounting  

The weather station is mounted with the supplied brackets.  
 

 

Mounting bracket in anodized aluminium. 
 
The weather station is supplied with mounting bolts in stainless steel and wall/pole 
mounting kit, for mounting on a pole with a diameter of 30-

58mm (1.2’’ - 2.3’’). 

 
For best possible measurements, WindowMaster recommends placing the weather 
station at least 2m above the highest point of the building. 
 

 

1.  Mount the sensor on to the bracket mount.  
2.  Secure the sensor to its mount using the supplied screws and washers.  
3.  Torque screws to a max of 1.5Nm.  

 
The bracket uses a mounting clamp for attaching to a vertical pipe/pole with a diameter of 30-58mm. Mount at the top of a pipe/pole 
to ensure a clear unobstructed measurement view. 
 

Note

: The mounting pipe/pole should first be degreased and when assembling the bracket clamp the outer clamp nuts need to be 

tightened evenly to a torque of 3Nm. 
 
The moving plate part of the clamp needs to be reversed for pipes/poles below 38m diameter. 
Screw an Earth cable minimum 6mm

2

 to the bracket chassis using screw and terminal fixing supplied (see drawing above).  

 
 
 
 
 
 
 
 

 

Attach Earth 
cable here 

Содержание WOW 600

Страница 1: ...k used under the license by WindowMaster International A S WindowMaster International A S Skelstedet 13 DK 2950 Vedb k 1 WOW 600 Weather station wiring configuration Wetterstaton Anschluss Konfigurati...

Страница 2: ...4 Configuration 5 1 5 Important information 5 2 DE 5 2 1 Beschreibung 5 2 2 Montage 5 2 3 Anschluss 7 2 4 Konfiguration 7 2 5 Wichtige Informationen 8 3 DK 8 3 1 Beskrivelse 8 3 2 Montage 8 3 3 Tilsl...

Страница 3: ...o function on WindowMaster MotorControllers smoke panels 1 2 Mounting The weather station is mounted with the supplied brackets Mounting bracket in anodized aluminium The weather station is supplied w...

Страница 4: ...4 WOW 600 must be aligned towards north see illustration below 1 3 Wiring WCC 3x0 Plus and WSC 3x0 Plus panels WSC 5xx panels...

Страница 5: ...en Niederschlag die relative Luftfeuchtigkeit die Windgeschwindigkeit und richtung Dar ber hinaus ist sie mit einer GPS Antenne f r die Zeiterfassung ausgestattet Die Wetterstation wird mit einer 20m...

Страница 6: ...ohrs um eine klare und ungehinderte Messperspektive zu gew hrleisten Hinweis Das Montagerohr muss vorher entfettet werden Ziehen Sie bei der Montage der B gelschelleeinheit die u eren Schellenmuttern...

Страница 7: ...m ssen Sie sicherstellen dass die Installation den aktuellen nationalen Richtlinien entspricht 2 4 Konfiguration Wenn die WOW 600 an die Steuerung WCC 3x0 Plus WSC 3x0 Plus oder WSC 5xx angeschlossen...

Страница 8: ...mmen med MotorControllere WCC 3x0 Plus ver x4 samt brandcentraler WSC 3x0 Plus ver E4 og WSC 5xx ver E2 fra WindowMaster WOW 600 er kundetilpasset version af GMX600 fra Gill Instruments Vejledning for...

Страница 9: ...e et klart og uhindret m leperspektiv Bem rk Monteringsr ret skal f rst affedtes N r du samler beslagklemmeenheden skal de yderste klemskruem trikker sp ndes j vnt til et moment p 3 Nm For master r r...

Страница 10: ...man skal sikre sig at installationen overholder g ldende nationale retningslinjer 3 4 Konfiguration N r WOW 600 er tilsluttet styringen WCC 3x0 Plus WSC 3x0 Plus eller WSC 5xx skal styringen konfigure...

Страница 11: ...3 5 Vigtig information Emballagen kan bortskaffes sammen med almindeligt husholdningsaffald Elektriske produkter m ikke smides ud med almindeligt husholdningsaffald men skal bortskaffes i henhold til...

Отзывы: