18
2.
Installation sequence
– Insert sensor for safety thermostat auger tube into the holder as far as possible – Fig. 15.
– Suspend auger motor (located in the combustion chamber of the pellet boiler) at back via lug and at front from cen-
tering screw – Fig. 16.
– Secure auger motor with 2 M8x16 screws – Fig. 17.
– Screw gear to auger at the bottom of the hopper with M6x12 hexagon screws and a U-washer – Fig. 18.
– Plug in the auger motor and proximity switch plugs – Fig. 19.
Fig. 15
Insert sensor for safety thermostat au-
ger tube as far as possible
1
2
3
Fig. 16 Hook the auger motor into place
1
2
3
Fig. 17
Screw the auger motor into place
Centering screw
Lug
2 x
M8x16
1
2
3
Fig. 18 Mount gear
1 x
M6x12
Fig. 19 Connect plugs for auger motor
and proximity switch
2 x
EN