Customer display control
GB - 11
P
OSITION CURSOR
The cursor position can be defined with this ESC sequence. The cursor is not visible on
the display whilst this is being carried out. The following ESC sequence (for example)
can be implemented:
Code
Hexadecimal
ESC’[‘’Py’;’Px’’H’
1B 5B 31 3B 31 48
The parameters are transferred as ASCII characters and have the following meaning:
Parameter
Meaning
Py
This parameter defines the line.
Px
This parameter defines the column.
Example
The parameters are to replaced with the following values if you wish to position the
cursor at the very beginning of the first line:
If you select 0 for the parameter value, this is interpreted as 1 by the display. If, on the
other hand, you select a value which is greater than the maximum line and column
value, the display will interpret this value as the maximum value permitted.
The cursor is positioned in the first column of the first line if no parameter values are
entered.
Note:
This command is not applicable if the selected country code is Thai.