background image

Installation of the Connector

Tube-based 

Press the re lea se knob mar ked with
the ar row in the dra wing (1) and
dis con nect the hin ge from the
cus to mer  dis play  (2).

Thre ad the ca ble through the
adap ter (3) and then through the
hinge (4).

TUBE-BASED

6



‚

ƒ

„

Содержание BA63

Страница 1: ...BA63 USB Customer Display Product Manual Edition January 2004 ...

Страница 2: ...cluding rights created by patent grant or registration of a utility model or design are reserved Delivery subject to availability technical modifications possible Pentium is a registered trademark of the Intel Corporation MS DOS Windows 95 Windows 98 Windows NT Windows XP and Wind ows CE are registered trademarks of the Microsoft Corporation BEETLE is a registered trademark of Wincor Nixdorf Inter...

Страница 3: ...tating Plate 8 Customer Display Control 11 Control Sequences 12 Backspace without deleting 12 Line feed 12 Carriage return 13 Delete display 13 Position cursor 13 Delete to end of line 14 Set country code 14 POS Commands 16 Updating the Firmware 19 System Connection 21 Cable Connection 22 Test Functions 23 Test by short circuiting J0 23 Test by short circuiting J1 23 Short circuiting J2 23 Technic...

Страница 4: ...tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Modifications not authorized by the manufacturer may void users authority to operate this device This class A digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la classe A est conforme à la norme NMB 00...

Страница 5: ...r Nixdorf generally guarantees a limited warranty engagement for 12 months beginning with the date of delivery This warranty engagement covers all those damages which occur despite a normal use of the product Damages because of n improper or insufficient maintenance n improper use of the product or unauthorized modifications of the product n inadequate location or surroundings will not be covered ...

Страница 6: ...recovered thus saving energy and costly raw materials Please do not stick labels onto plastic case parts This would help us to re use components and material At this time there are still some parts that are not reusable Wincor Nixdorf guarantees the environmentally safe disposal of these parts in a Recycling Center which is certified pursuant to ISO 9001 So don t simply throw your BA63 on the scra...

Страница 7: ... implemented Implementation of VFD technology ensures that the customer display is ergonomically designed to achieve a high degree of readability irrespective of the cashier s angle of vision The display is connected to the point of sale system via a Standard USB interface The voltage 5 V DC is also supplied via this interface The BA63 works with operating systems that support USB and it has to be...

Страница 8: ...ased installation The tube diameter is 40 mm 0 3 mm 0 1 mm The tube is not included in the delivery The connection cables are available in different lengths Cables have to be ordered separately and will be delivered separately 5 GENERAL NOTES ...

Страница 9: ...he Connector Tube based Press the release knob marked with the arrow in the drawing 1 and disconnect the hinge from the customer display 2 Thread the cable through the adapter 3 and then through the hinge 4 TUBE BASED 6 ...

Страница 10: ...Connect the hinge and adapter Secure the connector cable in the strain relief The distance between the strain relief and the tip of the connector must be 73 mm 2 mm 7 TUBE BASED 73mm 2 mm ...

Страница 11: ...e customer display and plug the adapter hinge into the customer display again until it locks into place Base Rotating Plate Press the release knob marked with the arrow in the drawing 1 and disconnect the hinge from the customer display 2 BASE ROTATING PLATE 8 ...

Страница 12: ...Thread the cable through the base 3 and then through the hinge 4 Connect the base and the hinge 9 BASE ROTATING PLATE ...

Страница 13: ...er display again until it locks into place A metal bracket of the strain relief is situated on the bottom side of the base table Loosen one of the screws see arrow push the bracket aside and guide the connector cable from inward to outward under the bracket through the recess Tighten the screw BASE ROTATING PLATE 10 ...

Страница 14: ...ropriate ESC sequences The following functions are available n The cursor can be moved to the desired position n Characters resp areas can be deleted n Country specific character sets can be selected n special test functions or communication commands can be performed via POS commands 11 CUSTOMER DISPLAY CONTROL ...

Страница 15: ...ecimal 08 moves the cursor one space to the left If there is a character in the position to which the cursor moves it is not deleted This command is ignored if the cursor is already at the very start of the line Line feed The LF command hexadecimal 0A moves the invisible cursor down a line if it is positioned in one of the first three lines of the display The column position remains unchanged The ...

Страница 16: ... 4A Position cursor The cursor position can be defined with this ESC sequence The cursor is not visible on the display whilst this is being carried out The following ESC sequence for example can be implemented Code Hexadezimal ESC Py Px H 1B 5B 31 3B 31 48 The parameters are transferred as ASCII characters and have the following meaning Parameter Meaning Py This parameter defines the line Px This ...

Страница 17: ...ete to end of line This command deletes the characters from the cursor cursor position included to the end of the line The position of the cursor remains unchanged The ESC sequence is as follows Code Hexadezimal ESC 0 K 1B 5B 30 4B Set country code The following ESC sequence is implemented in order to select a countryspecific character set Code Hexadezimal ESC R n 1B 52 02 The hexadecimal value n ...

Страница 18: ...ain 2 0C Latin America Furthermore PC code pages which contain additional country specific display codes can be selected by ESC R n with the following codes Country code Code page Character set Country 30 437 Standard Latin America 31 850 Latin 1 International Scandinavia Latin America 32 852 Latin 2 Hungary Poland Czechia Slowakia 15 CONTROL SEQUENCES ...

Страница 19: ...3 in 5 x 7 matrix display are indicated POS Commands Write Data Command Data can be Escape sequences control characters or data to be issued Escape sequences can be hacked up 1st part in frame n 2nd part in frame n 1 Command 02H 00H Data Count Data Bytes Length max 32 That is the size of the report Maximum of reference data to be transferred 32 3 29 bytes i e when configurating an Escape sequence ...

Страница 20: ...fig Response Response Length Byte Status Byte 0 Status Byte 1 Status Byte2 s Status Response Pn1 Pn2 Pn3 Pn4 Pn5 Pn6 Pn7 Pn1 type of display 1 digit ASCII e g 2 Pn2 actual code page 4 digits ASCII e g 0852 Pn3 country code 2 digits ASCII e g 02 Pn4 number of lines 1 digit ASCII e g 2 Pn5 columns line 2 digits ASCII e g 20 Pn6 code page loaded in Space Page 4 digits ASCII e g 0850 Pn7 serial number...

Страница 21: ...or Test Response Response 04H Status Byte 0 Status Byte 1 Status Byte 2 Status Bytes s Status Response Status Response Response 04H Status Byte 0 Status Byte 1 Status Byte 2 Status Byte 0 Bit 0 4 ignore Bit 5 Hardware Error Bit 6 ignore Bit 7 Device not ready to receive commands Status Byte 1 Bit 0 6 ignore Bit 7 Undefined command received command reject Status Byte 2 Bit 0 7 ignore CONTROL SEQUEN...

Страница 22: ...n BA63 Nonspecific virgin device is relevant Roughly the BA63 USB software can be divided into a loader and a firmware The selection BA63 is for a case where the BA63 USB already has a firmware and therefore knows which type of device it is If there is no firmware at all i e just the loader only Nonspecific can be used Nonspecific also may be used in case something went wrong during the update i e...

Страница 23: ...t the BA63 normally offers two interfaces to the system line display interface corresponds to BA63 firmware update interface corresponds to Nonspecific virgin device When a firmware update is started the BA63 clears the firmware and reenumerates to just having a firmware update interface Then the firmware update is performed and when finished the BA63 again performs a reset and reenumerates to hav...

Страница 24: ...JP0 JP1 JP2 ON ON ON Self test Font test Manual Upgrade OFF OFF OFF The illustration below shows the position of the jumpers The screen can be removed by pressing the two clips of the housing underneath the screen Thus the jumpers are accessible Jumpers can be set by using pointed tweezers or paper clips Even a crosswise setting of the jumpers will not lead to damage of the display circuitry If on...

Страница 25: ...Cable Connection The customer display cable is a standard cable according to the USB specifications Please use only cables delivered or released by Wincor Nixdorf CABLE CONNECTION 22 ...

Страница 26: ...es as entering the ESC sequence ESC 0c and ESC 2 nn 2 2 20c As long as the jumper J0 is set to ON the test will be performed as closed loop See also page 21 Test by short circuiting J1 All presentable characters of all character sets will be output nearly every second As long as the jumper J1 is set to ON the test will be performed as closed loop See also page 21 Short circuiting J2 The display is...

Страница 27: ...ric characters Matrix 5 x 7 pixel Height 9 5 mm Width 6 2 mm Color green Self test function possible via software control using ESC sequences and wire jumpers Interface USB 1 1 Transmission modes 12 Mbits s gross data rate Voltage supply 5V Vusb max 440 mA System connection USB 1 1 compatible with USB 2 0 Dimensions Height with base 165 mm Width 206 mm Depth 46 mm Weight 0 5 kg TECHNICAL DATA 24 ...

Страница 28: ...Herausgegeben von Published by Wincor Nixdorf International GmbH D 33094 Paderborn Bestell Nr Order No 01750075148A Printed in Singapore ...