Winco WL22000VE/A Скачать руководство пользователя страница 8

8

REV A

OPM-110

INITIAL START UP

The throttle control on these generators is preset and locked to operate 

at 3600 RPM (nominal) with no load speed set at 3690 RPM. Only 

a trained service technician should be allowed to adjust this speed 

setting.

NOTICE: ENGINE START LOCKOUT

This unit will not start if it is low on oil. The lubricating oil level must be 

at the full mark before the engine will start and run.

BASIC OPERATION

CAUTION: EQUIPMENT DAMAGE:

Always start the unit with the circuit breaker open, never start with the 

load applied. Always keep the battery charged, especially during cold 

weather operation.

  1. Check oil level, refill as needed.

  2. Turn on the fuel supply.

  3. Move the choke to the full “ON” position for starting. A warm 

    engine will require less choking than a cold one.

  4. Turn the key to the start position. The starter life is improved 

    by using shorter start cycles. Do not operate the starter more 

    than 15 seconds during each minute. Repeat as necessary.

  5. When the engine starts, release the key and open the choke 

  gradually.

  6. The engine should promptly come up to operating speed.

CAUTION: EQUIPMENT DAMAGE

Never permit the choke to remain on after the engine has run for a 

short time. It is not necessary to choke the engine when it is warm. 

Avoid over-choking.

STARTING HINTS

1. COLD WEATHER

  A. Use the proper oil for the temperature expected.

  B. Use fresh winter grade fuel. Winter grade gasoline is blended to 

    improve starting. Do not use summer grade gasoline.

2. HOT WEATHER

  A. Use the proper oil for the temperature expected.

  B. Use only summer blended gasoline. Using gasoline left over from 

    winter may cause the unit to vapor lock.

STOPPING AND STORING

  1. Move the key to the “OFF” position.

  2. Turn off the fuel supply valve.

  3. Before extended storage (over 30 days) certain precautions 

 

must be taken to ensure the fuel doesn’t deteriorate and clog the 

 

fuel system.

NOTE:

 The use of a fuel additive, such as Sta-Bil or equivalent will 

minimize the formation of gum deposits during storage. The additive 

may be added to gasoline in the engines fuel tank or to gasoline in a 

storage container.

  A. Add the fuel stabilizer to the fuel in the tank and run for 2 minutes 

    to circulate the stabilizer throughout the fuel system.

  B. Remove the remaining fuel from the fuel tank, it must be drained 

    into an approved container.

  C. Start the engine and allow it to run until all the fuel in the 

    carburetor and the fuel lines has been used up and the engine 

  stops.

NOTE:

 Running the engine to use up the fuel in the lines and 

carburetor will still leave a small amount of fuel in carburetor. It is best 

extended storage practice to treat the fuel before draining.

  D. While the engine is warm, drain the oil and refill with fresh oil.

  E. Remove the spark plug, pour approximately 1/2 oz. (15cc) of 

    engine oil into the cylinder and crank slowly to distribute the oil. 

    Replace the spark plug.

  E. Clean dirt and chaff from cylinder, cylinder head fins, blower 

    housing, screen, and muffler areas.

  F. Store in a clean and dry area.

Содержание WL22000VE/A

Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS WL22000VE A GENERATOR MANUAL...

Страница 2: ...lowed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the generator USING THIS MANUAL Congratulations on your choi...

Страница 3: ...J1 Spark Plugs 792015 Air Filter 692519 Pre Cleaner Filter 692520 Oil Filter 842921 Fuel Filter 845125 Spark Plug Gap 0 030 in Intake Valve Clearance 0 004 0 006 in Exhaust Valve Clearance 0 007 0 009...

Страница 4: ...tion B Guard against electric shock C Avoid contact with live terminals or receptacles D Use extreme care if operating this unit in rain or snow E Use only three prong grounded plugs and extension cor...

Страница 5: ...This generator is capable of producing 79 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatibility Remember that power taken from C redu...

Страница 6: ...keeping the crankcase full cannot be overemphasized Engine failures resulting from inadequate or improper lubricant are considered abuse and not covered by the generator or engine manufacturer s warra...

Страница 7: ...o the Bat terminal Make sure all connections are clean an tight Reverse the sequence when disconnecting disconnect the negative cable first These engines produce enough direct current to keep the batt...

Страница 8: ...gasoline is blended to improve starting Do not use summer grade gasoline 2 HOT WEATHER A Use the proper oil for the temperature expected B Use only summer blended gasoline Using gasoline left over fr...

Страница 9: ...hich grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 are good technical references STANDARD PORTABLE GENERATOR Your WINCO port...

Страница 10: ...ne generator described in this manual are approximately as follows under varying loads LOAD vs OUTPUT Generator Load Speed RPM Frequency Hz Voltage 120V Recpt 240V Recpt None 3690 61 5 120V 240V Half...

Страница 11: ...L1 and Line 2 L2 1 25 25 50 50 75 75 100 It is good practice to monitor the YourGen Meter when applying load This will ensure the generator is balanced Balanced Unbalanced 120 Volt and 240 Volt recep...

Страница 12: ...ain valve for your convenience Attach a neoprene hose and drain the oil into an approved container 3 Remove the oil filter and dispose of it properly 4 Before you install the new oil filter clean the...

Страница 13: ...ely dirty replace with a new filter You can use pressurized air not to exceed 30 psi to clean the filter Always blow the compressed air from inside to the outside 6 Wash the pre cleaner F in liquid de...

Страница 14: ...ly should it be needed in an emergency GENERATOR MAINTENANCE Any major generator service including the installation or replacement of parts should be performed only by a qualified electrical service t...

Страница 15: ...15 REV A OPM 110 G1 G1 G2 G2 G2 N N N N N N N GND GND GND GND GND GND G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM...

Страница 16: ...e consumables or labor This warranty does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WIN...