Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS WL22000VE A GENERATOR MANUAL...
Страница 2: ...lowed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the generator USING THIS MANUAL Congratulations on your choi...
Страница 3: ...J1 Spark Plugs 792015 Air Filter 692519 Pre Cleaner Filter 692520 Oil Filter 842921 Fuel Filter 845125 Spark Plug Gap 0 030 in Intake Valve Clearance 0 004 0 006 in Exhaust Valve Clearance 0 007 0 009...
Страница 4: ...tion B Guard against electric shock C Avoid contact with live terminals or receptacles D Use extreme care if operating this unit in rain or snow E Use only three prong grounded plugs and extension cor...
Страница 5: ...This generator is capable of producing 79 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatibility Remember that power taken from C redu...
Страница 6: ...keeping the crankcase full cannot be overemphasized Engine failures resulting from inadequate or improper lubricant are considered abuse and not covered by the generator or engine manufacturer s warra...
Страница 7: ...o the Bat terminal Make sure all connections are clean an tight Reverse the sequence when disconnecting disconnect the negative cable first These engines produce enough direct current to keep the batt...
Страница 8: ...gasoline is blended to improve starting Do not use summer grade gasoline 2 HOT WEATHER A Use the proper oil for the temperature expected B Use only summer blended gasoline Using gasoline left over fr...
Страница 9: ...hich grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 are good technical references STANDARD PORTABLE GENERATOR Your WINCO port...
Страница 10: ...ne generator described in this manual are approximately as follows under varying loads LOAD vs OUTPUT Generator Load Speed RPM Frequency Hz Voltage 120V Recpt 240V Recpt None 3690 61 5 120V 240V Half...
Страница 11: ...L1 and Line 2 L2 1 25 25 50 50 75 75 100 It is good practice to monitor the YourGen Meter when applying load This will ensure the generator is balanced Balanced Unbalanced 120 Volt and 240 Volt recep...
Страница 12: ...ain valve for your convenience Attach a neoprene hose and drain the oil into an approved container 3 Remove the oil filter and dispose of it properly 4 Before you install the new oil filter clean the...
Страница 13: ...ely dirty replace with a new filter You can use pressurized air not to exceed 30 psi to clean the filter Always blow the compressed air from inside to the outside 6 Wash the pre cleaner F in liquid de...
Страница 14: ...ly should it be needed in an emergency GENERATOR MAINTENANCE Any major generator service including the installation or replacement of parts should be performed only by a qualified electrical service t...
Страница 15: ...15 REV A OPM 110 G1 G1 G2 G2 G2 N N N N N N N GND GND GND GND GND GND G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM...
Страница 16: ...e consumables or labor This warranty does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WIN...