CALIFORNIA EVAPORATIVE EMISSION CONTROL

WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board is pleased to explain the evaporative emission control system’s 
warranty on your model 2013 or later generator.  In California, new equipment that uses small off-road 
engines must be designed, built, and equipped to meet the State’s stringent anti-smog standards.  
WINCO must warrant the evaporative emission control system on your generator for the period listed 
below provided there has been no abuse, neglect or improper maintenance of your equipment.  

Your evaporative emission control system may include parts such as: carburetor, fuel tanks, fuel lines, 
fuel caps, valves, canisters, fi lters, vapor hoses, clamps, connectors and other associated components.

MANUFACTURER’S WARRANTY COVERAGE

The evaporative emission control system is warranted for two years.  If any evaporative emission re-
lated parts on your equipment are defective, the parts will be repaired or replaced by WINCO.

OWNER’S WARRANTY RESPONSIBILITIES:

As the generator owner, you are responsible for performance of the required maintenance listed in 
your owner’s manuals. WINCO recommends that you retain all receipts covering maintenance on your 
generator, but WINCO cannot deny warranty solely for lack of receipts.

As the generator owner, you should be aware that WINCO may deny you warranty coverage if your 
generator or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifi ca-
tions. 

You are responsible for presenting your generator to a WINCO service center as soon as the problem 
exists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 
days.  If you have a question regarding your warranty coverage, you should contact WINCO at 507-
357-6831.

Содержание WC5000E

Страница 1: ...INSTALLATION AND OPERATORS MANUAL INDUSTRIAL PORTABLE WC5000H E WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 wincogen com...

Страница 2: ...5 Battery Installation 6 INITIAL START UP 8 Basic Operation 8 Manual Starting 8 Electric Starting 8 Stopping Storage 9 Operating Speed 9 CONNECTING THE LOADS 10 Wiring 10 ENGINE CARE 11 GENERATOR CAR...

Страница 3: ...dren c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate e Store fuel on...

Страница 4: ...air flow and may cause a fire PLEASE NOTE There are 3rd party companies making enclosures for generators that have been properly engineered The use of these 3rd party enclosures is acceptable as long...

Страница 5: ...move all the information sheets and manu als from the carton 1 This generator set was in good order when shipped Inspect the generator set promptly after receiving it If any damage is noted notify the...

Страница 6: ...the engine If the oil level drops below a certain point the low oil module on the engine will shut it down This low oil warning system will automatically stop the engine before the oil level reaches a...

Страница 7: ...dless of the generator load CAUTION EQUIPMENT DAMAGE When using these generators to power a home or construction trailer the Conserv R switch must be left in the off position Some appliances in homes...

Страница 8: ...d the engine stops Note Running the engine to use up the fuel in the lines and carburetor will still leave a small amount of fuel in the carburetor It is best for extended storage to treat the fuel be...

Страница 9: ...nit Capabilities page 4 These engine generator sets are inherently self reg ulating based on engine speed The engine governor will automatically adjust itself to the load No harm to the generator will...

Страница 10: ...Engine ser vice is very likely available from a nearby authorized dealer or distributor Check the yellow pages of your local telephone directory under Engines Gasoline for the closest engine repair c...

Страница 11: ...mly on spark plug If this happens reform the terminal to fit firmly on spark plug tip 5 Carbon Canister Designed to collect store and dispose of fuel vapors created in the fuel tank fuel system The ca...

Страница 12: ...rt Low Oil Level Fouled spark plug Out of fuel Start switch in Off position Fuel valve turn off Plugged fuel filter Blown fuse in key switch Voltage too low Engine speed is too low Generator overloade...

Страница 13: ...13 5070 00 60706 242 CONTROL PANEL WIRING DIAGRAM...

Страница 14: ...earest WINCO Authorized Service Center or to WINCO Inc at Le Center Minnesota THERE IS NO OTHER EXPRESS WARRANTY To the extent permitted by law any and all warranties including those of merchantabilit...

Страница 15: ...RER S WARRANTY COVERAGE The evaporative emission control system is warranted for two years If any evaporative emission re lated parts on your equipment are defective the parts will be repaired or repl...

Страница 16: ...5070 00 16 60706 242 WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 wincogen com...

Отзывы: