OPM-142/D
CLEANING & INSPECTION
Use a vacuum cleaner or dry low pressure compressed air
(regulated at 25-35 PSI) to clean the generator periodically.
WARNING:
Do NOT clean the generator while it is running.
Proceed as follows:
1. Remove control box cover. Vacuum or blow dust or
debris from the control box. Inspect all wiring for correct
routing, fraying insulation, and secure connections.
2. Remove end cover. Vacuum or blow dust and debris
from the inside of the generator. Inspect wiring for loose
connections, fraying insulation and correct wire routing.
3. Replace end cover and control box cover.
GENERATOR STORAGE
Before storing the generator, apply a heavy coat of grease
to the splined input shaft. Store the generator in a sheltered
area, where it is protected against snow, rain, and excessive
dust.