background image

TABLE OF CONTENTS

PRODUCT SAFETY

1

SPECIFICATIONS

2

PREPARATION

UNPACKING

2

OIL REQUIREMENTS

2

FUEL REQUIREMENTS

2

COOLANT REQUIREMENTS

3

BATTERY CONNECTIONS

3

OPERATIONS

FRONT PANEL DESCRIPTION

3

RECEPTACLE AND BREAKERS

5

FULL POWER CONNECTIONS

5

ENGINE CONTROL MODULE

5

VOLTAGE REGULATOR

6

SELECTING THE CORRECT

VOLTAGE

7

START-UP CHECKLIST

7

ELECTRIC STARTING

7

REMOTE STARTING

8

CONNECTING THE LOADS

8

UNIT STORAGE

9

50 CYCLE OPERATION

9

MAINTENANCE

9

PREVENTIVE  MAINTENANCE

9

WIRING DIAGRAMS

DC ELECTRICAL SCHEMATIC

10

RECEPTACLE PANEL

11

CIRCUIT BREAKER PANEL

11

CONTROL PANEL

12

CONTROL PANEL WIRING DETAIL

13

AC SCHEMATIC

14

AC WIRING DIAGRAM

15

WARRANTY

16

Read and understand all instructions in the manual
before starting and operating the generator set.

USING THIS MANUAL

Congratulations on your choice of a Winco generator set.
You have selected a high-quality, precision-engineered
generator set designed and tested to give you years of
satisfactory portable service.

To get the best performance from your new engine
generator set, it is important that you carefully read and
follow the operating instructions in this manual.

Should you experience a problem please follow the
“Things To Check” near the end of this manual. The
warranty listed in this manual describes what you can
expect from WINCO should you need service assistance
in the future.

PROPER USE AND INSTALLATION

You must be sure your new engine generator set is:
*

Properly serviced before starting

*

Operated in a well ventilated area

*

Exhaust gases are dispersed safely

*

Wired by a qualified electrician

*

Operated only for its designed purposes

*

Used only by operators who understand its operation

*

Properly maintained

COPY YOUR MODEL AND SERIAL NUMBER
BELOW FOR FUTURE REFERENCE.

No other WINCO generator has the same serial number
as yours.  It is important that you record the number and
other vital information here, if you should ever need to
contact us on this unit it will help us to respond to your
needs faster.

MODEL____________________________________

SERIAL  NUMBER____________________________

PURCHASE  DATE____________________________

DEALER___________________________________

Page i

Содержание MDS50R3/B

Страница 1: ...Mobile Diesel Systems 60706 135 INSTALLATION AND OPERATION MANUAL OWNERS MANUAL MDS50R3 B ...

Страница 2: ...ce To get the best performance from your new engine generator set it is important that you carefully read and follow the operating instructions in this manual Should you experience a problem please follow the Things To Check near the end of this manual The warranty listed in this manual describes what you can expect from WINCO should you need service assistance in the future PROPER USE AND INSTALL...

Страница 3: ... into closed rooms i e through windows walls or floors 4 NOISE HAZARD Excessive noise is not only tiring but continual exposure can lead to loss of hearing A Use hearing protection equipment when working around this equipment for long periods of time B Always operate with the housing doors closed to reduce the operational noise level 5 CLEANLINESS Keep the generator and surrounding area clean A Re...

Страница 4: ...e at the time of delivery have the driver sign and describe the loss or damage in the memo of loss or damage section on the freight bill Then contact the carrier to get instructions on filing a claim When loss or damage is discovered after the equipment is delivered but not seen at the time of delivery it is referred to as concealed damage Separate any dam aged material and contact the carrier for...

Страница 5: ...cting the battery is done in reverse disconnecting the negative cable first and then the positive cable WARNING POTENTIAL BATTERY EXPLOSION THIS UNIT USES A NEGATIVE GROUND CONNECT ING THE NEGATIVE CABLE FIRST MAKES THE BATTERY POSITIVE TERMINAL HOT CONNECTING THE POSITIVE CABLE LAST MAY RESULT IN ACCI DENTAL SHORT CIRCUIT OF THE POSITIVE BAT TERY TERMINAL TO ANY OF THE SURROUNDING METAL SURFACES ...

Страница 6: ...LTAGE of the battery under static at rest conditions and under cranking and charging conditions The voltmeter indicates not only the condition of the charging system but also indicates the battery reserve under cranking load in cold weather d Running Time Meter 7 This DC meter records the total hours the engine has run 5 AC Generator Controls a Voltage adjust rheostat 8 Controls the output voltage...

Страница 7: ... amp circuit breaker mounted just above it THIS RECEPTACLE UTILIZES A SPECIAL HUBBELL PLUG HUBBELL PART NUMBER CS 6365 C FULL POWER LOAD CONNECTIONS and BREAKERS This Mobile Diesel Power System is equipped with both high voltage 480 and low voltage 208 240 main line breakers The breakers are interlocked with a lockable bar to insure that only one breaker can be turned on at a time A full power out...

Страница 8: ...ed indicator light can mean a loss of control signal during the previous run period i e bat charging alternator belt broken TROUBLE SHOOTING HINT This is of particular note since the tendency is to pursue only overspeed faults The overspeed signal source battery charging alternator is a key component in this system and must be checked out thoroughly whenever an OS shutdown occurs Please note The c...

Страница 9: ...phase L2 L3 208 volts single phase L1 L3 208 volts single phase L1 N 120 Volts L2 N 120 Volts L3 N 120 volts 3 277 480 Three Phase High Series WYE configura tion This configuration will produce the following line to line and line to neutral outputs The 120 volt receptacles are the only panel receptacles powered in this voltage configuration They are limited to 12 Amps total L1 L2 L3 480 Volts thre...

Страница 10: ...to this line 9 Connect the neutral to the transfer switch using the same wire size 10 For isolated neutral operation remove the jumper wire between the ground lug and neutral connection block 11 Ground the Mobile Diesel generator set using an 8 ft copper ground rod or other approved grounding system Connect 4 Awg Copper cable from the ground lug on the generator to the ground rod 12 Set the select...

Страница 11: ...t to operate at 50 HZ instead of the standard 60 HZ This is done by cutting the two leads marked HZ that come out of the regulator This will change the regulator for 60 HZ operation to 50 HZ operation If it should become necessary to change it back to 60 HZ you would need to splice the leads together again MAINTENANCE The ultimate aim of a preventive maintenance program is to maintain the equipmen...

Страница 12: ...Page 10 DC ELECTRICAL SCHEMATIC ...

Страница 13: ...Page 11 RECEPTACLE PANEL WIRING CIRCUIT BREAKER PANEL ...

Страница 14: ...Page 12 CONTROL PANEL WIRING DIAGRAM ...

Страница 15: ...Page 13 CONTROL PANEL WIRING DETAIL ...

Страница 16: ...Page 14 AC SCHEMATIC ...

Страница 17: ...Page 15 AC WIRING DIAGRAM ...

Страница 18: ...for a particular purpose are limited to 12 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied warranty and some states do no allow the exclusion or limitation of incidental or consequential damages so the above limitations may not apply in every instance This warranty gives you specifi...

Отзывы: