TABLE OF CONTENTS

SAVE THESE INSTRUCTIONS 

2

TESTING POLICY 

2

SPECIFICATIONS 3

SAFETY 4

IMPORTANT SAFETY INSTRUCTIONS

CALIFORNIA PROPOSITION 65

ANSI SAFETY DEFINITIONS

INTRODUCTION 5

INTENDED USES

RESTRICTED USES

UNIT CAPABILITIES 

5

GENERATOR CONNECTIONS

STARTING ELECTRIC MOTORS

PREPARING THE UNIT  

6

UNPACKING

VENTILATION

GASOLINE

FUEL SUPPLY

LUBRICATION

OIL RECOMMENDATIONS

OIL ALERT SYSTEM

BATTERY INSTALLATION

BATTERY CHARGING

INITIAL START UP 

8

BASIC OPERATION

STARTING HINTS

CONNECTING THE LOADS 

9

APPLYING THE LOADS

GROUNDING

WIRING

ENGINE CARE 

10

MAINTENANCE SCHEDULE

CHECKING THE OIL LEVEL

CHANGING THE OIL

DUAL ELEMENT AIR FILTER

SPARK PLUG

CARBON CANISTER

GENERATOR CARE 

11

EXERCISING THE GENERATOR

GENERATOR MAINTENANCE

CLEANING

TROUBLESHOOTING 11

OUTLINE DRAWINGS 

12

DISTRIBUTION WIRING SCHEMATICS 

13

EC22000VE AC WIRING 

14

24 MONTH LIMITED WARRANTY 

16

SAVE THESE INSTRUCTIONS

This manual contains important instructions that should be followed 

during installation and maintenance of the generator. Read and 

understand all instructions in the manual before starting and operating 

the generator.

USING THIS MANUAL

Congratulations on your choice of a WINCO generator. You have 

selected a high-quality, precision-engineered generator designed and 

tested to give you years of satisfactory service.

To get the best performance from your new generator, it is important 

that you carefully read and follow the operating instructions in this 

manual.

Should you experience a problem please follow the “Troubleshooting 

Tables” near the end of this manual. The warranty listed in the manual 

describes what you can expect from WINCO should you need service 

assistance in the future.

COPY YOUR MODEL AND SERIAL NUMBER HERE

No other WINCO generator has the same serial number as yours. If 

you should ever need to contact us concerning this unit, it will help us 

to respond to your needs faster.

MODEL __________________________________________________

SERIAL NUMBER _________________________________________ 

PURCHASE DATE _________________________________________

DEALER NAME ___________________________________________

DEALER PHONE # ________________________________________

TESTING POLICY

Before any generator is shipped from the factory, it is fully checked 

for performance. The generator is loaded to its full capacity, and the 

voltage, current, and frequency are carefully checked.

Rated output of generator is based on engineering tests of typical units, 

and is subject to, and limited by, the temperature, altitude, fuel, and 

other conditions specified by the manufacturer of applicable engines.

Содержание EC18000VE/D

Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS EC18000VE D EC22000VE A GENERATORS MANUAL...

Страница 2: ...ou have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that yo...

Страница 3: ...4 0 006 in Exhaust Valve Clearance 0 007 0 009 in Oil Capacity 78 80 oz 2 4 2 5 qts EC22000VE Starting Watts 22 000 22 000 22 000 22 000 Running Watts 19 000 19 000 19 000 19 000 Volts 120 240 120 208...

Страница 4: ...resent a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator...

Страница 5: ...pliance or tool nameplates for the current and voltage to ensure compatibility Remember tha power utilized from C reduces the power available from both A and B and vice versa The EC22000 utilizes the...

Страница 6: ...nt line This is to prevent the escape of fuel vapors in to the atmosphere 3 You need to have a primer bulb in the fuel line to prime the fuel from the tank to the fuel pump The vacuum fuel pump on the...

Страница 7: ...th are going to vary depending on your installation These engines are all negative ground The positive battery cable must be connected to the open large terminal on the start solenoid This terminal ma...

Страница 8: ...slightly lower voltage when the generator is loaded to its full capacity than when running no load The slight variation in speed also affects the frequency of the output current This frequency variati...

Страница 9: ...ers mounted in some type of distribution panel This location will also be where you will install your neutral to ground bond You must wire four separate wires from the generator 2 hot 1 neutral and 1...

Страница 10: ...e and remove the spark plug wire to prevent it from accidently being started b Remove oil drain plug at base of the engine Ref B and drain the oil into an approved container c Remove the oil lter Ref...

Страница 11: ...p the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling At least yearly remove the blower housing on the engine and clean the chaff and dirt out of...

Страница 12: ...6 FLAT WASHER 2 9 467 000 HHCS 5 16 18X 75 2 REVISIONS REV IRN DESCRIPTION DATE BY APP D A ORIGINAL MVW B REDESIGNED RECEPTACLE BOX 6 20 12 PJY MVW C 3630 60706 231 ADDED 3 24 2015 KS DRC D 5271 REPLA...

Страница 13: ...13 REV D 60706 231 EC18000VE EC22000VE DISTRIBUTION WIRING SCHEMATICS 120 240 SINGLE PHASE 120 208 120 240 THREE PHASE 277 480 THREE PHASE...

Страница 14: ...OW WYE THREE PHASE LO 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS Page 14 0210 10 REV B 60706 197 EE PHASE AC WIRING H AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS E HIGH WYE S EC22000VE AC WIRI...

Страница 15: ...REV B THREE PHASE AC WIRING D SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE D 120 240 VOLTS E PHASE AC WIRING DELTA E PHASE AC WIRING GLE PHASE 240 VOLTS THREE PHASE DELTA 120 240 VOLT...

Страница 16: ...a particular purpose are limited to 24 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of imp...

Отзывы: