  C. Remove the oil filter and dispose of it properly.

  D. Before you install the new oil filter, clean the filter mounting base 

    and coat the seal of the new oil filter will clean engine oil.

  E. Install the oil filter by hand until the gasket contacts the oil filter 

    adapter, then tighten the oil filter 1/2 to 3/4 turns.

  F. Replace oil drain bolt making sure the sealing washer is in place.

  G. Remover the oil filter plug and refill with new oil. Make sure to use 

    the proper grade oil based on your operating temperature.

NOTE:

 This engine requires 78 to 80 ounces (2.4 to 2.5 quarts) of oil if  

it is completely drained. Use caution when refilling the engine as some 

residual oil may have remained in the engine. Always use the dipstick 

when filling the engine with oil to prevent overfilling.

  H. Replace filter plug.

  I. Start the engine and warm it up.

  J . After warming up the engine, recheck the oil level and refill as 

    necessary to bring it to the proper level.

 

DUAL ELEMENT AIR FILTER

Clean and/or replace the foam pre-cleaner and the air filter annually or 

every 100 hours. Service more often under dusty conditions.

WARNING: EQUIPMENT DAMAGE

Never start or run the engine with the air filter removed.

  A. Loosen snaps (A) and 

    remove cover (B).

  B. Remove the nut (D) and the 

  retainer 

(E).

  C. Remove the air filter (F). 

  D. Remove the pre-cleaner (G) 

    from the air filter.

  E. To loosen debris, gently tap the 

    air filter on a hard surface. If the 

    air filter is excessively dirty 

    replace with a new filter. 

    You can use pressurized air 

    (not to exceed 30 psi) 

    to clean the filter. Always blow the compressed air from inside to 

  the 

outside.

  F. Wash the pre-cleaner in liquid detergent and water. Then allow it 

    to thoroughly air dry. DO NOT oil the pre-cleaner.

  G. Install the pre-cleaner to the air filter.

  H. Install the air filter and secure the retainer and nut.

  I. Install and secure the cover.

SPARK PLUG

Replace annually or every 300 hours of operation. Always replace with 

the same spark plug that came in the engine and check gap before 

installing. Spark plug gap is 0.030”. Poor spark will also occur if spark 

plug wire does not fit firmly on spark plug. If this happens, reform the 

terminal to fit firmly on spark plug tip.

11

3110-00

60706-239

ENGINE CARE

If major engine service or repair is required, contact 

an authorized engine service center.  The manufac-

turer of these engines has established an excellent 

world-wide engine service organization.  Engine ser-

vice is very likely available from a nearby authorized 

dealer or distributor.  Check the yellow pages of your 

local telephone directory under “Engines-Gasoline” 

for the closest engine repair center or ask the dealer 

from whom you purchased the power plant. 

1.

 Change the oil

 after the 

rst 5 hours of operation 

and yearly or 100 hours thereafter under normal op-

erating conditions.  Change engine oil every 50 hours 

of operation if the engine is operated under heavy 

load, or in high ambient temperatures.

a.  Start the engine and warm it up, stop the engine  

  and remove the spark plug wire to prevent it 

  from accidently being started.

b.  Remove oil drain plug at base of the engine 

  (Ref “B”) and drain the oil into an approved 

 container.

c.  Remove the oil 

lter (Ref “C”) and dispose of it

 properly.

d.  Before you install the new oil 

lter, lightly lubri- 

  cate the oil 

lter gasket with fresh clean oil.

e.  Install the oil 

lter by hand until the gasket 

  contacts the oil 

lter adapter, then tighten the oil  

lter 1/2 to 3/4 turns. 

f.  Replace oil drain plug.

g.  Remove oil 

ller plug and re

ll with new oil.

  Refer to the table on page 5 for the proper    

  grade of oil based on your operating  

 temperature. 

NOTE:  This engine requires 78 to 80 ounces of oil 

if it is completely drained.  Use caution when re

lling

the engine as some residual oil may have remained 

in the engine.  Always use the dipstick when 

lling

the engine with oil to prevent over

lling.

h. Replace 

ller plug.

I.  Start the engine and warm it up.

J.  After warming up the engine, recheck the oil   

  level and re

ll as necessary to bring it to the 

  proper level.  See page 5 for proper oil level.

2.

Checking the Oil Level

:  The oil level must al-

ways be checked before the engine is started.  Take 

care to remove any dirt or debris from around the 

oil

ll plug before removing.  Be sure the oil level is 

maintained.  Fill to the “

FULL

” mark on the dipstick.

3.

Dual Element Air Filter

:  Clean and/or replace 

foam pre-cleaner and air 

lter annually or every 100 

hours.  Service more often under dusty conditions.

WARNING:  EQUIPMENT DAMAGE

Never start or run the engine with the air 

lter re-

moved

a.  Loosen snaps (Ref “A”) and remove cover.   

  Ref “B”

Maintenance Chart

First 5 Hours

x

Change oil

Every 8 Hours or Daily

x

Check engine oil level

x

Clean area around muffler and controls

Every 100 Hours or Annually

x

Clean or change air filter

*

x

Clean pre-cleaner (if equipped)

*

x

Change engine oil and filter

x

Replace spark plug

x

Check muffler and spark arrester

Every 250 Hours or Annually

x

Check valve clearance. Adjust if necessary.

Every 400 Hours or Annually

x

Change air filter

x

Replace fuel filter

x

Clean air cooling system

*

x

Clean oil cooler fins

*

*

In dusty conditions or when airborne debris is present, clean more often.

A

B

F

E

D

G

C

B

ENGINE CARE

MAINTENANCE SCHEDULE

If major engine service or repair is required, contact an authorized 

engine service center. The manufacturer of these engines has 

established an excellent world-wide engine service organization. 

Engine service is very likely available from a nearby authorized dealer 

or distributor. See following table.

CHECKING THE OIL LEVEL

The oil level must always be checked before the engine is started. 

Refer to page 5 of this manual for instructions on checking the oil level. 

Take care to remove any dirt or debris from around the oil plug before 

removing. Be sure the oil level is maintained. 

CHANGING THE OIL

Refer to the Maintenance Schedule Chart for required oil change 

intervals.

  A. Start the engine and warm it up, stop the engine and remove the 

    spark plug wire to prevent it from accidentally being started.

  B. This engine has an oil drain valve for your convenience. Attach a 

    neoprene hose and drain the oil into an approved container.  

 

Neoprene hose, 1/2” I.D.

Cut to length

Содержание EC18000VE/D

Страница 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS EC18000VE D EC22000VE A GENERATORS MANUAL...

Страница 2: ...ou have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that yo...

Страница 3: ...4 0 006 in Exhaust Valve Clearance 0 007 0 009 in Oil Capacity 78 80 oz 2 4 2 5 qts EC22000VE Starting Watts 22 000 22 000 22 000 22 000 Running Watts 19 000 19 000 19 000 19 000 Volts 120 240 120 208...

Страница 4: ...resent a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator...

Страница 5: ...pliance or tool nameplates for the current and voltage to ensure compatibility Remember tha power utilized from C reduces the power available from both A and B and vice versa The EC22000 utilizes the...

Страница 6: ...nt line This is to prevent the escape of fuel vapors in to the atmosphere 3 You need to have a primer bulb in the fuel line to prime the fuel from the tank to the fuel pump The vacuum fuel pump on the...

Страница 7: ...th are going to vary depending on your installation These engines are all negative ground The positive battery cable must be connected to the open large terminal on the start solenoid This terminal ma...

Страница 8: ...slightly lower voltage when the generator is loaded to its full capacity than when running no load The slight variation in speed also affects the frequency of the output current This frequency variati...

Страница 9: ...ers mounted in some type of distribution panel This location will also be where you will install your neutral to ground bond You must wire four separate wires from the generator 2 hot 1 neutral and 1...

Страница 10: ...e and remove the spark plug wire to prevent it from accidently being started b Remove oil drain plug at base of the engine Ref B and drain the oil into an approved container c Remove the oil lter Ref...

Страница 11: ...p the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling At least yearly remove the blower housing on the engine and clean the chaff and dirt out of...

Страница 12: ...6 FLAT WASHER 2 9 467 000 HHCS 5 16 18X 75 2 REVISIONS REV IRN DESCRIPTION DATE BY APP D A ORIGINAL MVW B REDESIGNED RECEPTACLE BOX 6 20 12 PJY MVW C 3630 60706 231 ADDED 3 24 2015 KS DRC D 5271 REPLA...

Страница 13: ...13 REV D 60706 231 EC18000VE EC22000VE DISTRIBUTION WIRING SCHEMATICS 120 240 SINGLE PHASE 120 208 120 240 THREE PHASE 277 480 THREE PHASE...

Страница 14: ...OW WYE THREE PHASE LO 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS Page 14 0210 10 REV B 60706 197 EE PHASE AC WIRING H AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS E HIGH WYE S EC22000VE AC WIRI...

Страница 15: ...REV B THREE PHASE AC WIRING D SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE D 120 240 VOLTS E PHASE AC WIRING DELTA E PHASE AC WIRING GLE PHASE 240 VOLTS THREE PHASE DELTA 120 240 VOLT...

Страница 16: ...a particular purpose are limited to 24 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of imp...

Отзывы: