1. These engine-generator sets are designed for portable heavy duty
commercial use. Receptacles are provided on the control panel to
permit 120 and 240 Volt portable appliances and tools to be plugged
directly into them. A 4-wire receptacle (two hot, one ground, and one
neutral) has been provided on the control panel for use in temporary
power applications requiring 120/240 Volt power. Consult a licensed
electrician for wiring the TemPower plug and connecting it as temporary
service.
2. If the generator set is connected to an existing distribution system,
a fully isolated manual transfer switch must be installed. The transfer
switch prevents damage to the generator and the other circuit
components if main line power is restored while the generator is
connected. Installing a transfer switch also permits the use of normal
fusing.
3. Many homes and construction sites are wired for at least 60 to 100
Amp entrance service, much greater than the capacity of this portable
generator. When installing the generator at these sites, a secondary
emergency distribution panel may have to be installed that works with
a GFCI breaker. The emergency distribution panel must be installed by
a licensed electrician according to all applicable codes. The electrician
will move the critical circuits to be powered during the outage to the
emergency panel. Keep in mind only a limited amount of amperage is
available from the generator set. Some circuit breakers may still have
to be turned off to prevent an overload on the generator during the
initial start up. See the nameplate on your generator for the amperage
capabilities of your unit.
CAUTION: EQUIPMENT DAMAGE
Failure to properly limit and balance the load a[[lied to the generator
will cause the generator to produce low voltage and may damage
the engine generator set. It may also cause severe damage to the
loads connected to the generator at that time. Improper loading of the
generator set constitutes abuse and will not be covered by warranty.
ENGINE CARE
MAINTENANCE SCHEDULE
If major engine service or repair is required, contact an authorized
engine service center. The manufacturer of these engines has
established an excellent world-wide engine service organization.
Engine service is very likely available from a nearby authorized dealer
or distributor. See following table.
CHECKING THE OIL LEVEL
The oil level must always be checked before the engine is started.
Refer to page 5 of this manual for instructions on checking the oil level.
Take care to remove any dirt or debris from around the oil plug before
removing. Be sure the oil level is maintained.
CHANGING THE OIL
Refer to the Maintenance Schedule Chart for required oil change
intervals.
1. Start the engine and warm it up, stop the engine and remove the
spark plug wire to prevent it from accidentally being started.
2. This engine has an oil drain valve for your convenience. Attach a
neoprene hose and drain the oil into an approved container.
3. Allow the used oil to drain completely, then reinstall the oil drain
plug and a new washer, and tighten the oil drain plug securely.
Dispose of used motor oil in a manner that is compatible with the
environment. Do not throw it in the trash, pour it in the ground, or pour
it down a drain.
4. With the engine in a level position, fill with the recommended oil
to the upper limit mark on the dipstick.