9

REV C

OPM-118

NOTE:

 Running the engine to use up the fuel in the lines and 

carburetor will still leave a small amount of fuel in carburetor. It is best 

extended storage to treat the fuel before draining.

  D. While the engine is warm, drain the oil and refill with fresh oil.

  E. Clean dirt and chaff from cylinder, cylinder head fins, blower 

    housing, screen, and muffler areas.

  F. Store in a clean and dry area.

OPERATING SPEED

The engine-generator must be run at the correct speed in order to 

produce the proper electrical voltage and frequency.

CAUTION: EQUIPMENT DAMAGE

The output voltage should be checked to ensure the generator is 

working properly prior to connecting a load to the generator. Failure to 

do so could result in damage to equipment plugged into the unit and 

possible injury to the individual.

All engines have a tendency to slow down when a load is applied. 

When the electrical load is connected to the generator, the engine is 

more heavily loaded, and as a result, the speed drops slightly. This 

slight decrease in speed, together with the voltage drop within the 

generator itself, results in a slightly lower voltage when the generator 

is loaded to its full capacity than when running no load. The slight 

variation in speed also affects the frequency of the output current. 

This frequency variation has no appreciable effect in the operation of 

motors, lights, and most appliances. However, electronic equipment 

and clocks will be affected if correct RPM is not maintained. See Load 

vs. Output chart.

Although individual units and models vary slightly, the normal voltage 

and frequency of the engine-generator described in this manual are 

approximately as follows, under varying loads:

LOAD vs. OUTPUT

Generator Load

Speed 

(RPM)

Frequency 

(Hz)

Voltage

None

3690

61.5

125V

Half

3600

60.0

120V

Full

3510

58.5

115V

The speed of the engine was carefully adjusted at the factory so that 

the generator produces the proper voltage and frequency. For normal 

usage, the speed setting should not be charged. If the generator is 

being run continuously on a very light load, it is often advisable to lower 

the operating speed slightly. Position the throttle lever for the desired 

engine speed.

CAUTION: EQUIPMENT DAMAGE:

SPEED ADJUSTMENTS SHOULD ONLY BE MADE BY A QUALIFIED 

SERVICE TECH. 

Whenever making any speed adjustments, check the 

unit with a voltmeter and a frequency meter or a tachometer and be 

sure the voltage and speed are correct.

Lower voltage may damage both the generator and any load connected 

to it. Running the engine at excessively high speeds results in high 

voltage, which may significantly shorten the life of appliances being 

used.

Output voltage should be checked periodically to ensure continued 

proper operation of the generating plant and appliances. If the 

generator is not equipped with a voltmeter, it can be checked with a 

portable meter.

Содержание DP5000/T

Страница 1: ...TORS DP5000 T GENERATOR MANUAL 5 9 6 216 5 9 51 6 5 37 21 7 33 3 25 1 6 0 5 5 029 6 0 5 5 37 21 47 2 7 66 0 6 5 6 5 51 1 7 27 685 6 1 2 3257 0 167 7 21 5 2 86 2876 3 6 6 5 1 21 27 685 6 1 335 7 7 3 7 7 7 5 1 02 3 57 6 0 7 6 5 1 217 16 35235 7 5 1 250 7 21 21 1 72 1 2 81 87 25 86 6 352 7 0 61 216 1 1 352 5 72 5 1 0 1 8 5 RI 5 ...

Страница 2: ...tenance of the generator Read and understand all instructions in the manual before starting and operating the generator USING THIS MANUAL Congratulations on your choice of a WINCO generator You have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that you careful...

Страница 3: ...RT2VMT2 Code GCBGT Spark Plugs BPR5ES NGK Air Filter 17211 899 000 Spark Plug Gap 0 030 in Intake Valve Clearance 0 006 0 0008 in Exhaust Valve Clearance 0 008 0 0008 in Oil Capacity 38 4 oz 1 2 qts TESTING POLICY Before any generator is shipped from the factory it is fully checked for performance The generator is loaded to its full capacity and the voltage current and frequency are carefully chec...

Страница 4: ...arth 2 FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator set or fuel tank D Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate E Store fuel only in an app...

Страница 5: ... may cause excessive vibration and damage to the engine generator set DO NOT operate and or store the unit outside during inclement weather without adequate protection from the elements Failure to do so will damage the unit DO NOT install and operate this generator in a small compartment i e generator compartments of vehicles motor homes or travel trailers These compartments will not allow enough ...

Страница 6: ... EQUIPMENT DAMAGE Running the generator set under these conditions may result in damage to the generator stator as well as the motor winding The heavy surge of current required for starting motors is required for only an instant The generator will not be damaged if it can bring the motor up to speed in a few seconds of time If difficulty is experienced in starting motors turn all other electrical ...

Страница 7: ...utomatically stop the engine before the oil level reaches critical danger point This feature is designed to prevent costly repairs and downtime CAUTION EQUIPMENT DAMAGE Allowing the engine to shutdown repeatedly on low oil level may cause excessive wear which can be cumulative GASOLINE When using gasoline always use fresh clean unleaded fuel The engine is certified to operate on unleaded gasoline ...

Страница 8: ...eturn it gently to prevent damage to the starter 7 If the choke rod has been moved to the CLOSED position to start the engine gradually move it to the OPEN position as the engine warms up 8 The engine should promptly come up to operating speed CAUTION EQUIPMENT DAMAGE Never permit the choke to remain on after the engine has run for a short time It is not necessary to choke the engine when it is wa...

Страница 9: ...le effect in the operation of motors lights and most appliances However electronic equipment and clocks will be affected if correct RPM is not maintained See Load vs Output chart Although individual units and models vary slightly the normal voltage and frequency of the engine generator described in this manual are approximately as follows under varying loads LOAD vs OUTPUT Generator Load Speed RPM...

Страница 10: ...pplication dependent Carefully evaluate your planned use of your generator to understand which grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 are good technical references STANDARD PORTABLE GENERATOR Your WINCO portable generator ships with a bonded neutral You can safely use this generator without external grounding as lon...

Страница 11: ...ding to all applicable codes The electrician will move the critical circuits to be powered during the outage to the emergency panel Keep in mind only a limited amount of amperage is available from the generator set Some circuit breakers may still have to be turned off to prevent an overload on the generator during the initial start up See the nameplate on your generator for the amperage capabiliti...

Страница 12: ... quarts of oil if it is completely drained Use caution when refilling the engine as some residual oil may have remained in the engine Always use the dipstick when filling the engine with oil to prevent overfilling 6 After warming up the engine recheck the oil level and refill as necessary to bring it to the proper level DUAL ELEMENT AIR FILTER Check maintenance schedule for recommended service per...

Страница 13: ...ese areas clean may cause overheating and permanent damage to the unit 2 Periodically clean muffler area to remove all grass dirt and combustible debris to prevent a fire 3 On engine mufflers equipped with spark arresters the spark arrester must be removed every 50 hours for cleaning and inspection Replace if damaged 1 Unsnap the air cleaner cover clips remove the air cleaner cover and remove the ...

Страница 14: ...efective capacitor Circuit breaker trips Defective load Defective receptacle Excessive load Problem Possible Causes Voltage too high Engine speed is too high Generator overheating Overloaded Insufficient ventilation No output voltage Short in load disconnect Tripped or defective circuit breaker Broken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective ...

Страница 15: ...15 REV C OPM 118 RECEPTACLE PANEL WIRING DIAGRAM GND TIME METER ...

Страница 16: ...ce consumables or labor This warranty does not cover travel time mileage or labor for removal or re installation of WINCO product from its application Normal wear and tear Costs of rental equipment WINCO does not warrant engines Engines are covered exclusively by the warranties of their respective manufacturers WINCO does not warrant component parts that are warranted by their respective manufactu...