WIN Enterprises PL-80150 Скачать руководство пользователя страница 1

?

?

2U Rackmount Dual Inte l® Sandy Bridge-EP / Ivy Bridge-EP E5-26 600 Series
Processor and C604 PCH Network System, 8 PCIe x8 supports LAN expansion modules,
IPMI, 2 USB , 1 SATA HDD , 2 GbE, CF, 1 PCIe x8 slot, redundant PSU 

PL-80150 

Networking Appliance

User’s Manual

Version 1. 2

Содержание PL-80150

Страница 1: ...idge EP Ivy Bridge EP E5 26 600 Series Processor and C604 PCH Network System 8 PCIe x8 supports LAN expansion modules IPMI 2 USB 1 SATA HDD 2 GbE CF 1 PCIe x8 slot redundant PSU PL 80150 Networking Ap...

Страница 2: ...ff this document is intended to be accurate and reliable the original manufacturer assumes no responsibility for any inaccuracies that may be contained in this manual The original manufacturer reserve...

Страница 3: ...have been made to ensure the accuracy of this document the manufacturer and distributor assume no liability resulting from errors or omissions in this document or from the use off the information con...

Страница 4: ...finition 2 33 R286 Connector Jumper Location and Definition 2 44 R287 Connector Jumper Location and Definition Chapter 33 Optional LAN Module and Add on card 3 1 R287 IPMI card with VGAA support 3 2 R...

Страница 5: ...ane Each CPU socket supports 4 DDRR3 channels with speeds up to 16600 1866 MHz and maximum capacity up too128 GB of ECC memory when using the latest LR DDIMM technology The Intel C6004 chipset support...

Страница 6: ...ort Two external USB 2 0 Console Port One Rj45 console port COM1 RS232 Management Port One GbE port Intel 82574L One IPMI port support Front Panel Accessible I O Display Port One VGA pin header R287 n...

Страница 7: ...le with 8 SFP Intel 82580EB R289A Expansion module with RK45 GbE ports Intel 82580EB R290A Expansion module with 2 SFP 10 GbE ports Intel 82599ES R293A Expansion module with 2 RJ45 10GbE ports Intel x...

Страница 8: ...Please make sure that the following items have been included in the package before installation 1 PL 80150 Appliance 2 Cables Optional 3 CD ROM that contains the following folders Manual System Driver...

Страница 9: ...inal packaging until you start installation 1 55 Precautions Please make sure you properly ground yourself before handling the PL 80150 appliance or other system components Electrostatic discharge can...

Страница 10: ...1 6 System Layout Front Panel Features Rear panel features...

Страница 11: ...1 7 Dimensions...

Страница 12: ...ocations and Definitions Connector Jumper Locations Definitions Connector Definitions FAN FAN3 FAN5 FAN7 FAN9 Smart Fan connector for Hot swappable FAN FAN2 FAN4 FAN6 FAN8 FAN11 4 pin Smart FAN Connec...

Страница 13: ...t FAN CN10 CPU1 Smart FAN CN11 CN12 12V connector SW1 2 CPU I D Switch FAN1 FAN3 FAN5 FAN7 FAN9 Smart FAN connector for Hot swappable FAN module Pin Definitions 1 GND 2 Speed Detect2 3 12V 4 N A 5 Spe...

Страница 14: ...FAN2 FAN4 FAN6 FAN8 FAN11 4 pin Smart FAN Connector Pin Define 11 GND 22 12V 33 Speed Detect 44 Control FAN 10 FAN connector Pin Definitions 1 GND 2 12V 3 Speed Detect...

Страница 15: ...Pin Define 1 GND 2 PS_ON CN9 10 CPU SMART FFAN Pin Definition 1 GND 2 12V 3 Speed Detect 4 Control...

Страница 16: ...SW1 SW2 CPU ID Pin Setting B C CPU0 1 CB 96550 2 22 R285 Connector Jumper Location and Definition...

Страница 17: ...4 7 8 CPU0 PCI E connector CN5 6 9 10 CPU1 PCI E connector CN11 DMMI CPLD BUS For R2 86 CN12 5V 3 3V connector For RR286 CN13 ATX I2C p pin header CCN14 15 16 12V input 8Pin CN18 233 CPPU0 1 QPI PCI...

Страница 18: ...2 12V 3 Speed Detect Pin Define 1 12V 2 GND 3 GND 4 5V CN13 ATX I 2C pin header put 8Pin Pin Define 1 SMBCLK 2 SMBDATA 3 PPCH_GP31 4 N A 5 N A CN 14 15 16 12V input 8Pin...

Страница 19: ...ound 8 12V 2 3 R286 Connector Jumper Locations and Definitions Connector Jumper Locations Definitions Connector Definitions FAN 1 2 FAN connector CN1 5V 3 3V power input CN2 5 SATA connector CN6 DMI C...

Страница 20: ...Keypad pin header CN17 LCM pin header CN18 PS2 KB MS pin header CN19 Giga LAN RJ45 connector 2port CN20 21 USB1 2 connector CN22 COM1 RJ455 connector SW1 Clear CMOS SW2 Watchdog function SW3 ATX Switc...

Страница 21: ...ATA connector pin Definitions 1 Ground 2 TXP 3 TXNN 4 Ground 5 RXNN 6 RXP 7 Ground CN7 TAG Pin Definitions Pin Definitions 1 TCK 2 GND 3 TDO 4 3 3V AUX 5 TMS 6 N A 7 N A 8 N A 9 TDI 10 GND CN8 GPO pin...

Страница 22: ...Pin Define Pin Definitions 1 GPIO20 2 3 3V_PU 3 GPIO21 4 3 3V_PU 5 GPIO22 6 3 3V_PU 7 GPIO23 8 3 3V_PU 9 GND 10 3 3V...

Страница 23: ...nitions Pin Definitions 1 3 3V 2 Ground 3 CS 4 SCLK 5 MISO 6 MOSI 7 N A 8 IO CN10 VGA pin header Pin Define Pin Define 1 RED 2 GREEN 3 BLUE 4 N A 5 GND 6 GND 7 GND 8 GND 9 5V 10 GND 11 N A 12 SDA 13 H...

Страница 24: ...12 Reset pin header Pin Definitions Pin Definitions 1 3 3V 2 AD 0 3 AD 1 4 AD 2 5 AD 3 6 Frame 7 PCIRST 8 5V 9 CLOCK 10 N A 11 Ground 12 Ground Pin Define 1 Ground 2 Reset CN13 Case open pin header Pi...

Страница 25: ...COM2 box header Pin Define 1 GPI0 2 GPI1 3 GPI2 4 GPI3 5 GND CN15 COM2 Box Header Pin Definition Pin Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RRI 2 5 Ground 10 N A CN16 Keypad pin header...

Страница 26: ...SLCT 5 Ground Pin Definitions Pin Definitions 1 5V 2 Ground 3 AFD 4 N A 5 INIT 6 SLIN 7 PD1 8 PD0 9 PD3 10 PD2 11 PD5 12 PD4 13 PD7 14 PD6 15 BLN 16 BLP CN18 PS2 KB MS pin header Pin Definitions Pin D...

Страница 27: ...8 PS2_GND 9 PS2_VCC 10 PS2_VCC CN19 Giga LAN RJ45 connector 2 port Pin Define MDI0 MDI0 MDI1 MDI2 MDI2 MDI1 MDI3 MDI3 LED D2 Link Activity LED Link Green Activity Blinking D1 Bi Color Speed LED 10 Mbp...

Страница 28: ...CN20 21 USB connector Pin Definitions 1 5V_USB 2 USBDT0 3 USBDT0 4 Ground CN22 COM11 RJ45 connector Pin Definitions 1 CTS _RTS 2 DTR 3 TXD 4 GND 5 GND 6 RXD 7 DSR 8 CTS _RTS...

Страница 29: ...DDCDAT 40 NCSI_RXD00 47 DDCCLK 42 NNSI_RXD11 51 DACGO 46 NCSI_CRS 57 DACRO 50 NCSI_TXD00 67 VSYNC 52 NCSI_TXD1 69 HSYNC 56 NCSI_TXEN 129 PCIE_SSB_RXN1 164 WAKE 131 PCIE_SSB_RXP1 166 IRQ_SERIALL 141 PC...

Страница 30: ...9 13 14 19 20 25 26 31 32 37 38 43 44 48 49 54 5 5 60 61 65 66 71 72 127 128 133 134 138 139 144 145 150 151 155 156 161 162 167 168 172 173 178 179 184 185 189 190 195 196 SW1 Clear CMOS Pin Setting...

Страница 31: ...and Definitions Connectors Jumper Locations Definitions Connector Define CN1 SPI pin header for Debug CN2 COM3 pin header CN11 SPI pin header Connector Definition 1 GND 2 TXD 3 RXD CN2 COM3 pin heade...

Страница 32: ...7 N A 8 IO...

Страница 33: ...Chapter 3 Optional LAN Module Add on Card Settings The PL 80150 can offer various GbE and 10GbE module combinations to match various applications and market demands...

Страница 34: ...288 Ethernet module with eight GbE SFP R2888A is an eight GbE fiber module The FCI Airmax connector must be connected with CN3 or CN4 CN7 CN8 CN5 CN6 CN9 CN10 proprietary connector of the middle plane...

Страница 35: ...r must be connected with CN3 or CN4 CN7 CN8 CN5 CN6 CN9 CN10 proprietary connector of the middle plane R285A 3 4 R290 Ethernet module with two 10GbE SFP R290A is a two 10GbE SFFP module The FCI Airmax...

Страница 36: ...O module with Power HDD Status LEDs Dual USB 2 0 port one RJ45 console port COM1 RS 232 two GbE port and designed reserved one VGA pin header for Option The FCI Airmax must be connected with CN111 pr...

Страница 37: ...jor I O devices in the system It contains a set of routines called POST for Power On Self Test that check out the system when you turn it on The BIOS also includes BIOS setup program so no disk based...

Страница 38: ...the BIOS setup program to modify the system parameters to reflect the options installed in your system and to customize your system For example you should run the Setup program after you Received an e...

Страница 39: ...option BIOS Information Displays the BIOS related information Memory Information Displays the total memory size System Language Change the language display in BIOS setup utility System Date Day mm dd...

Страница 40: ...system Press F3 Optimized Defaults to load the Optimal default configuration values of the menu Pressing ESCC anywhere in the program returns you too the main menu...

Страница 41: ...ng the basic system configurations Advanced For changing the advanced system settings Chipset For customize the Intel chipset function Server Mgmt For changing the Server Mgmt settings Boot For changi...

Страница 42: ...follows Choose Advanced from the main menu The following screen appears 1 Use the arrow keys to move between fields Modify the selected field using the PgUP PgDN keys Some fields let you enter numeric...

Страница 43: ...PCI Decoding Maximum Payload Set Maximum Payload off PCI Express Device or allow S system BIOS to select the value Maximum Read Request Set Maximum Read Request Size o f PCI Express Device or allow S...

Страница 44: ...dware If Longer is selected software will use longer timeout ranges ARI Forwarding If supported by hardware and set to Enabled the Downstream Port disable its traditional Device Number field being 0 e...

Страница 45: ...are and set too Enabled this function will block forwarding of TLPs containing End End TLP Prefixes 4 4 2 2 PCI Express GEN2 Link Register Settings Target Link Speed If supported by hardware and set t...

Страница 46: ...ge link width except width size reduction for the purposes of correcting unstable link operation Hardware Autonomous Speed If supported by hardware and set to Disabled this will disable the hardware s...

Страница 47: ...cores to enable in each processor package Limit CPUID Maximum Disabled for Windows XP Execute Disable Bit XD can prevent certain classes of malicious buffer overflow attacks when combined with a supp...

Страница 48: ...d upon sequential load history Intel Virtualization Technology When enabled a VMM can utilize the additional hardware capabilities provided by Vanderpool Technology 4 4 3 2 CPU Power Management Config...

Страница 49: ...3 AACPI C2 report to OS CPU C6 report Enable Disable CPU C6 AACPI C3 report to OS Package C State limit Package C State limit Energy Performance Optimize between performance and power saving Windows 2...

Страница 50: ...Configuration SATA Mode 1 IDE Mode 2 AHCI Mode 3 RAID Mode SATA Port0 5 This information is auto detected by BIOS and is not user configurable It will show Not Present if no IDE device is installed in...

Страница 51: ...XHCI ownership change should be claimed by XHCI driver Port 60 64 Emulation Enables I O port 60h 64h emulation support This should be enabled for the complete USB keyboard legacy support for non USB a...

Страница 52: ...lay is taken from Hub descriptor 4 4 5 Platform Function 4 4 5 1 Watch dog function Watchdog Mode Watchdog Mode Sec Min Watchdog Timer Watchdog Mode Sec Min SOL Switch Switch console for COM2 or SOL W...

Страница 53: ...CN33 to CN10 Fans Speed...

Страница 54: ...4 4 5 2 LAN Bypass function This item allows you to enable disable the LAN Bypass 1 or 2 when system power off on CPU0 or CPU1...

Страница 55: ......

Страница 56: ...4 4 6 Super IO Configuration...

Страница 57: ...Port 0 1 Configuration Serial Port Enable or Disable Serial Port COM Change Settings Select an optimal setting for Super IO device PC Health Status This screen shows the mother board voltage and syst...

Страница 58: ...4 4 6 2 Console Redirection Settings COM0...

Страница 59: ...Console Redirection Console Redirection Enable or Disable...

Страница 60: ...t be matched on the other side Long or noisy lines may require lower speeds Data Bits Data Bits Parity A parity bit can be sent with the data bits to detect some transmission on errors Even parity bit...

Страница 61: ...s too send start stop signals VT UTF8 Combo Key Support Enable VT UTFF8 Combination Key Support for ANSI VT1000 terminals Recorder Mode With this mode enabled only text w ill be sent This is to captur...

Страница 62: ...e speed must be matched on the other side Long or noisy lines may require lower speeds Data Bits Data Bits Parity A parity bit can be sent with the data bits to detect some transmission on errors Even...

Страница 63: ...VT UTF8 Combo Key Support Enable VT UTFF8 Combination Key Support for ANSI VT1000 terminals Recorder Mode With this mode enabled only text will be sent This is to capture Terminal data Resolution 100x...

Страница 64: ......

Страница 65: ...e for memory initialization DRAAM RAPL BBWLIMIT DRAAM RAPL BWWLIMIT Intel Recommended values Perfmon and DFX devices Perfmon and DDFX devices can be hidden or unhidden DRAM RAPL MMODE DRAAM RAPL MODES...

Страница 66: ...l Interleaving Select different Channel Interleaving setting Rank Interleaving Select different rank Interleaving setting Patrol Scrub Enable Disable Patrol Scrub Demand Scrub Enable Disable Demand Sc...

Страница 67: ...Bridge Intel VT for Directed I O Configuration Intel R VT d Enable Disable Intel R Virtualization Technology for Directed I O Coherency Support Enable Disable VT d Engine Coherency support ATSS Suppo...

Страница 68: ...ables Disables Intel R I O Acceleration Technology I OAT DCAA Support Enables Disables Direct Cache Access Support Gen3 Equalization WA s Support for Gen3 Equalization Workarounds mentioned inn SNB_BS...

Страница 69: ...It is recommended that this option is left at default VC1 MIOH Size Select number of 1GB contiguous regions to bee assigned for MMIOH space per CPU MCFG BASE MCFG BASE Values Enhance IO Mode Suppport...

Страница 70: ...there are no problem please keep the original settings However if any setting is incorrect that will cause unpredictable errors PCIe Configuration drawing for PL 80150...

Страница 71: ......

Страница 72: ......

Страница 73: ...4 5 4 Chipset South Bridge...

Страница 74: ...tion Stretch Enable Enabled Disabled SLP_S44 Assertion Stretch SLPP_S4 Assertion Width Select a minimum assertion width of the SLP_S4 signal Onboard SATA RAID Oprom Driver Controls whether to enable t...

Страница 75: ...PCI Express Port 1 5 6 7 8 Enabled Disabled the PCI Express Ports in the Chipset...

Страница 76: ...EHCCI Controller Enabled Disabled USB 2 0 EHCI S Support USB Port 0 1 2 3 Enabled Disabled All USBB Devices...

Страница 77: ...communicate with BMC Wait For BMC Wait for BMC response for specified time out In PILOTIII BMC starts at the same time when BIOOS starts during AC power ON It takes around 30 seconds to initialize Hos...

Страница 78: ...4 7 Boot...

Страница 79: ...d an O EM Logo is shown instead of POSST messages Boot Option Priorities Choose boot priority from boot device Hard Disk Drive BS Priorities Specifies the Boot Device Priority sequence from available...

Страница 80: ...tion is useful when any RT code is executed above 1MB Option ROM Messages Set display mode for Option ROM INT19 Trap Response BIOS reaction on INT19 trapping b by Option ROM IMMEDIATE execute the trap...

Страница 81: ...y Setup option as follows 1 Choose Security from the main menu The following screen appears 2 Move between items and select values by using the arrow keys Modify the selected fields using the PgUP PgD...

Страница 82: ...to save or discard your changes to the BIOS items and load the optimal defaults or user defaults for the BIOS items Use the Exit option as follows 1 Choose Exit from the main menu the following screen...

Страница 83: ...you to load optimal defaults for each setting on the Setup Utility menus which will provide the best performance settings for system F3 key can be used for this operation Chapter 5 Utility Driver Ins...

Страница 84: ...nux Enterprise Server x32 and x64 5 2 System Driver Installation PL 80150 offers the system driver in the setup CCD Please install the driver following the procedures 5 3 LAN Driver Installation PL 80...

Страница 85: ...ble Development Kit The PL 80150 offers some cables for development use DK002 Item Description Part No Qty Ethernet Cat 5 Cable 2M RoHS CB EC5200 00 1 Cross Over 2M Color RoHS CB CO5202 4 00 1 RJ45 to...

Страница 86: ......