15
Function
GB
Via
Dip-Switch
different functions can be adjusted individually:
Dip 1
position “ON” =
shower-function
Maximum flushing time see time potentiometer
Dip 1 and 2 position “ON”:
Waterflow starts, when the user releases by close active
range (Dip 6 “ON”), or if user releases via push-button
(Dip 6 “OFF”) and remains as long as the user stays
in the infrared active range.
Minimum of switch-on time 10 s if the last activation is
more than 20 min ago (-> hot water)
Dip 2
position “OFF”:
The user is recognised as soon as he gets into the infrared
active range. The water flow
remains as long as the user
stays in the infrared active range.
Dip 3
Program Comfort & Self-close:
position “ON”:
Self-close function activated
position “OFF”:
Self-close function deactivated
Program Automatic:
position “ON”:
Cleaning stop can be activated by 5 close range
reflex impulses for 3 min
position “OFF”:
Cleaning stop can not be activated
Dip 4
position “ON”:
Continuous flow can be activated by 3 close range
reflex impulses for adjusted flushing time (if Dip 6 „OFF“
release waterflow via push button first). Stop continuous
flow via 3 anew reflex impulses.
position “OFF”:
Continuous flow can not be activated
Dip 5
position “ON”:
Hygiene flushing* after 24 hours without use
position “OFF”:
No hygiene flushing
Dip 6
position “ON”:
Activation by close range reflex (Dip 2 “ON”)
position “OFF”:
Activation by push-button (Dip 2 “ON”)
Dips 3, 4, und 5 can be adjusted at the programs individually.
*
Hygiene flushing can be activated, so that in the lines no stagnation water remains long time.
After 24 h without use an automatic flushing will be released for 10 s.
2