Urinal control
SanTec MICRO ONE
13
EN
ONE UR
Adjustments
Activation:
Dip-switch
Function
ON/OFF
Description
1
ONE Urinal-default
ON
1)
2
ONE Urinal-default
OFF
1)
3
ONE Urinal-default
OFF
1)
4
ONE Urinal-default
OFF
1)
5
Pre-flushing
ON
1)
Page 5
6
Dry-out protection
ON
1)
Page 5
6. DIP-switch:
Pre-flushing
DIP switch 5
To trigger a pre-flushing, if the urinal was not used within the time set on the cont-
roller 2 (5 minutes by default) .
Dip switch 5 ON = pre-flushing enabled (by default).
Dip switch 5 OFF = pre-flushing disabled.
Dry-out protection:
DIP switch 6
Serves to rinse water supply lines in order to remove stagnant water that accumulates
during longer periods of disuse (24 h by default).
Dip switch 6 ON = Dry-out protection enabled (by default).
Dip switch 6 OFF = Dry-out protection disabled.
1)
Programs and functions are pre-adjusted factory-made
ON
OFF
2 3 4 5 6
1
ON
OFF
2 3 4 5 6
1