12 Urinal control
SanTec MICRO ONE
EN
ONE UR
Adjustments
Setting elements on the electronics module - front
Setting elements on urinal sensor
1
Time controller
2
Time controle - pre-flushing
3
Connection IR-sensor
4
230 V power supply
connection
5
Magnetic valve connection
6
DIP switch
7
Reichweiten-Regler
Controller:
1.
Time controller
for main flushing
(1 s to 10 s adjustable,
5 s set by default).
2.
Time controller for
pre-flushing
if urinal was not used for a
certain period of time (5 min
set by default, adjustable
from permanent to 30 min)
7.
Range-controller
for the user detection in the
active range (30 - 70 cm
adjustable, 50 cm set by
default).
Rule applies to all controls:
Move counterclockwise
to decrease the setting.
Move clockwise to
increase the setting.
!