Wall fitting
WimTec OCEAN W6
25
EN
OCEAN W6
Function configuration
G. Function activation – DIP switch 1–6:
DIP switches Function
Factory setting
Description
1
-
-
-
2
Cleaning stop
OFF
Page 32
3
Continuous flow
OFF
Page 33
4
Stagnation flush
OFF
Page 34
5
Flush time (ON = 20 s,
OFF = 10 s
)
OFF
Page 35
6
Shut-off delay (ON = 3 s,
OFF = 1 s
)
OFF
Page 35
DIP switches:
Regulator controls:
F.
Flush time control
for the safety flow arrest, pre-
set to 1 min (adjustable from
10 s to 10 min).
E.
Interval control
for the smart stagnation flush
function (preset to 24 h, adjust-
able from 3 to 48 h).
G.
Range control
for the detection range, (preset
to 30 cm, adjustable from 1 cm
to 30 cm).
10
60
s
600
300
30
3
12
h
48
24
6
cm
1
30
5
10
20
cm
In general, the following applies:
!
Move anticlockwise to
decrease the setting.
Move clockwise to increase
the setting.