© by WilTec Wildanger Technik GmbH
Seite 17
http://www.wiltec.de
http://www.teich-tip.de
Version 3. 2017
http://www.aouye.eu
INSTRUCTION
1. take out the inlet & outlet connection from the accessories box, as shown in pic 1, pull up the small
handle to place
①
, then push the inlet&outlet connection to the cover
②
, fasten using the small
handle
2. As shown in pic 2, to set your filter up, the four buckles should be un-clamped from the main body,
then separate the cover from the main body of the filter.
3. Add the filter material as you like, the pic 3 is for your reference.
4. Insert the UVC lamp and quartz glass tube to the correct place. As shown in the pic 4, then fasten
the filter cover to the main body. (This instruction Only for HW-702B 703B 704B)
5. This product including automatic power-off protection system for UVC lamp. When the cover was
taken off from the main body, the UVC lamp will turned off automatically. So please take care of
the place of switch as shown in Pic 5. (This instruction Only for HW-702B 703B 704B) Otherwise
the UVC lamp will not work.
6. Repeat step, refasten the filter cover to the main body.
7. The small handle between the inlet&outlet connection is the shut of valve.
8. As shown in Pic 8, press down the primer button on top of the filter cover, so the filter will start to
absorb water through the pipe, repeat this if necessary until all pipe is full of water.
9. The UVC lamp must be replaced after 8000 hours of operation. Please cut off power when you
need to replace the UVC lamp. (Only for HW-702B 703B 704B)