REPLACE UVC LAMP 

 
 
 
 
 
5.   Open  the  filter  cover  according  to  Pic  2  (see  above),  place  the 
cover upside down. Then hold the quartz glass tube and rotate gently 
( pic 

) till the slot position (Pic 

).  

6.  take out the UVC lamp and change a new one(Pic 

7.  Put backl the quartz glass tube accordingly 
 
 
 
 
 
 
 
 
 
 

 
PLACE OF LOCATION 

 

Filter operation and problem solving  
 
Noise reduction/ external air  
Especially the suction intake /inlet and the connected suction surface must be  
checked for tightness and adjusted according to the water level of the aquarium.  
In case this is not possible due to aquarium technical reasons, seal the whole  
suction surface so that no external air can get into the filter.  
 
De-aerating/ evacuating air  
Take the return-flow hose that conducts the water from the filter to the tank and lead it into a clean 
bucket that is placed below the filter. Lead the hose into the bucket and carry out the dearation pro-
cess (evacuate the air) by activating the manual pump. Please make sure that the possible maximal 
flow is adjusted to the inlet-outlet connector. As soon as no air bubbles can be seen, seal the hose  
with a finger und and install it again as intended on the return pipe at the top  
edge of the aquarium.  
 
Leakage after installation or cleaning  
 

Содержание SunSun HW-702A

Страница 1: ...51 SunSun HW 703B 50952 SunSun HW 704A 50953 SunSun HW 704B Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificant ly Updating the documentation If you have suggestions for improvement or have found any irregularities please c...

Страница 2: ...hank you for purchasing this quality product To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corre sponding mains...

Страница 3: ...tainer volume ensures a cleaning with very large filter volume There is enough space for various filter media The SunSun Aquarium External Filter HW Series can be easily connected to aquariums with a big water volume So the operation of large sized aquariums becomes an simple exercise The aquarium external filter series provides for a high flow rate however it operates quietly The rubber stands pr...

Страница 4: ... by WilTec Wildanger Technik GmbH Seite 15 http www wiltec de http www teich tip de Version 3 2017 http www aouye eu PART LIST ...

Страница 5: ...d connection 2 4 2 Impeller set 12 draining skep cover 23 spray bar 5 A Buckle on the cover 13 draining skep 24 spray bar cover 5 B Buckle on the main body 14 input curvy bar 6 quartz glass tube 15 joint of dirtiness entrance 6 1 Quartz glass O ring 16 input bar PS PART 6 PART 6 1 AND PART 7 ONLY FOR HW 702B HW 703B HW 704B PS PART13 QTY IS 3PCS FOR HW 702A HW 703A HW 702B HW 703B PART 13 QTY IS 4...

Страница 6: ... filter cover to the main body This instruction Only for HW 702B 703B 704B 5 This product including automatic power off protection system for UVC lamp When the cover was taken off from the main body the UVC lamp will turned off automatically So please take care of the place of switch as shown in Pic 5 This instruction Only for HW 702B 703B 704B Otherwise the UVC lamp will not work 6 Repeat step re...

Страница 7: ...ia Bio Balls Bio balls are used in aquaristics as mechanical and biological filter mediat These balls offer bacteria a large area for their accumulation and are considered to be high performance filter media for powerful filter systems In contrast to other filter media bio balls have a virtually unlimited life span which makes them a popular and cheap filter medium for pond filter systems trickle ...

Страница 8: ...tness and adjusted according to the water level of the aquarium In case this is not possible due to aquarium technical reasons seal the whole suction surface so that no external air can get into the filter De aerating evacuating air Take the return flow hose that conducts the water from the filter to the tank and lead it into a clean bucket that is placed below the filter Lead the hose into the bu...

Страница 9: ... the lateral clamping points that connect the cover lid with the filter tank canister The remedy is here as simple as the failure itself You have to rinse and check the O rings Make sure that the spots where the O rings have to be inserted and positioned are free of dirt On these particular spots algae formation can appear and impair or damage the O rings sealing if no regularly cleaning is carrie...

Страница 10: ...ropean countries with a separate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this article you protect the environment and the health of your ...

Отзывы: