tuation in humidity. By setting the
required humidity, the alarm will
sound if the humidity measures
deviate from the setting. Important:
The humidity needs to be regulated
manually by adding water to the
incubator. The alarm will only notify
you, that the humidity is too low/
high. The setting needs to be ad-
justed manually for each breeding
phase.
Calibration
CA
0
–9.9
0.0
Measure with an additional ther-
mometer and match it according to
the deviation.
Heating start
LS
20
–30
℃
30
℃
Heating stop
HS
30
–50
℃
39.5
℃
Please note that the radiator will
switch off when reaching the en-
tered value, but will still radiate
some warmth and the temperature
might still rise a little bit in the incu-
bator. E.g., this means that a tem-
perature of 38
℃
can be reached,
when setting the temperature to
37.8
℃
. If you wish to avoid this,
the temperature of the heating stop
needs to be corrected downward.
Table 1: Adjustment of the finer parameters via the “set” buttons
4.
“Reset”: Keep this button pressed for a longer duration (approx. 8 s) will reset all set-
tings back to the factory settings, a peep sound can be heard. This is the only way to
reset the day count back to 0.
NOTE:
As from version quarter 1/2021, the procedure for resetting the number of breeding days has changed:
Press and hold
“Reset” for approx. 3 s, pull out the mains plug and plug it in again. The display shows
a countdown to 0. After the countdown has elapsed, the number of breeding days is reset.