-1
7
the air humidity is too low.
8
the heater is warming up.
Only with item 51185:
9
the egg candler currently is in use.
Description of the function buttons
The incubator has four buttons, which are required for the operation of the incubator. The buttons and
their possible combinations will be explained in the following paragraph. Before operating the incuba-
tor, ensure that it is properly plugged into the according area.
The buttons are positioned the following from bottom to top, next to the display on the right-hand side:
“set”, “+” and “–.” On the left-hand side of the display, there is the “reset” button.
1.
Press “reset” briefly: This button allows to turn the eggs manually.
•
Pushing the button once shortly will turn the eggs. The symbol
1
will blink in the dis-
play.
•
The countdown for the automatic turning is then reset to 2 h again.
2.
“Set”: This allows to set the basic temperature of the incubator.
•
Pushing the button once shortly will allow you to set the basic temperature (parameter
ID: PP).
•
By activating the “+” and “–” buttons, the desired temperature can be adjusted, by
pushing the “set” button again the data will be saved.
•
The pre-set temperature is 38.5
℃
, the basic temperature can be chosen between
30
℃
and 39.5
℃
.
3.
Holding “set” for longer than 3 s: This will open the menu for the finer parameter set-
tings (see table 1).
•
The individual parameter will show in the display, with an alphanumerical combination
(parameter ID).
•
With the “+” and “–” buttons you can choose between the individual parameters.
•
If you wish to adjust one of the parameters, push the “set” button then alter the shown
value up or downward by pushing the “+” or “–” button.
•
Pushing “set” again, will save the alteration and will bring you back to the standard
display.
Finer parame-
ters
Parameter
ID
Adjustment
range
Standard
setting
Note
Alarm,
fluctua-
tion of decreas-
ing temperature
AL
0
–15
℃
1.0
℃
This setting can be chosen, to
sound an alarm when a tempera-
ture below the setting is being
reached. After setting the parame-
ter “PP” to the value, e.g., to 38
℃
,
and you wish to have the alarm set
for 33
℃
, you will need to set the
parameter “AL” to 5.
Alarm,
fluctua-
tion of increas-
ing temperature
AH
0
–15
℃
1.0
℃
This setting can be chosen, to
sound an alarm when a tempera-
ture above the setting is being
reached. After setting the parame-
ter “PP” to the value, e.g., to 38
℃
,
and you wish to have the alarm set
for 40
℃
, you will need to set the
parameter “AH” to 2.
Alarm,
fluctua-
tion of humidity
AS
1
–99 %
45 %
Here you can adjust when the
alarm is to sound in case of a fluc-