the air humidity is too low. 

the heater is warming up. 

Only with item 51185:

 9 

the egg candler currently is in use. 

 

Description of the function buttons 

 
The incubator has four buttons, which are required for the operation of the incubator. The buttons and 
their possible combinations will be explained in the following paragraph. Before operating the incuba-
tor, ensure that it is properly plugged into the according area. 
 
The buttons are positioned the following from bottom to top, next to the display on the right-hand side: 
“set”, “+” and “–.” On the left-hand side of the display, there is the “reset” button. 
 

1. 

Press “reset” briefly: This button allows to turn the eggs manually.

 

 

Pushing the button once shortly will turn the eggs. The symbol 

1

 will blink in the dis-

play. 

 

The countdown for the automatic turning is then reset to 2 h again. 

 

2. 

“Set”: This allows to set the basic temperature of the incubator. 

 

Pushing the button once shortly will allow you to set the basic temperature (parameter 
ID: PP). 

 

By  activating  the  “+”  and  “–”  buttons,  the  desired  temperature  can  be  adjusted,  by 
pushing the “set” button again the data will be saved. 

 

The  pre-set  temperature  is  38.5 

,  the  basic  temperature  can  be  chosen  between 

30 

 and 39.5 

 

3. 

Holding “set” for longer than 3 s: This will open the menu for the finer parameter set-
tings (see table 1). 

 

The individual parameter will show in the display, with an alphanumerical combination 
(parameter ID). 

 

With the “+” and “–” buttons you can choose between the individual parameters. 

 

If you wish to adjust one of the parameters, push the “set” button then alter the shown 
value up or downward by pushing the “+” or “–” button. 

 

Pushing  “set”  again,  will  save  the  alteration  and  will  bring  you  back  to  the  standard 
display. 

 

Finer parame-

ters

 

Parameter 

ID

 

Adjustment 

range

 

Standard 

setting

 

Note

 

Alarm, 

fluctua-

tion  of  decreas-
ing temperature 

AL 

0

–15 

 

1.0 

 

This  setting  can  be  chosen,  to 
sound  an  alarm  when  a  tempera-
ture  below  the  setting  is  being 
reached.  After  setting  the  parame-
ter “PP” to the value, e.g., to 38 

and you wish to have the alarm set 
for  33 

,  you  will  need  to  set  the 

parameter “AL” to 5. 

Alarm, 

fluctua-

tion  of  increas-
ing temperature 

AH 

0

–15 

 

1.0 

 

This  setting  can  be  chosen,  to 
sound  an  alarm  when  a  tempera-
ture  above  the  setting  is  being 
reached.  After  setting  the  parame-
ter “PP” to the value, e.g., to 38 

and you wish to have the  alarm set 
for  40 

,  you  will  need  to  set  the 

parameter “AH” to 2. 

Alarm, 

fluctua-

tion of humidity 

AS 

1

–99 % 

45 % 

Here  you  can  adjust  when  the 
alarm  is  to sound  in  case  of a  fluc-

Содержание 51185

Страница 1: ...6 Similar to image may vary depending on model Read and follow the operating instructions and safety information before use Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ slightly ...

Страница 2: ...ervice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschw...

Страница 3: ...e to external influences the cable must not be repaired but needs to be exchanged This work must only be carried out by a qualified technician The rated voltage on the type label of 230 V AC needs to correspond to the existing mains voltage The device must never be lifted transported or attached from its electricity cable Ensure that the electrical plug connection is in an area protected from floo...

Страница 4: ...Information on breeding 1 How do the poultry eggs have to be stored before placing them into the incubator Hatching eggs should not be kept longer than ten to twelve days After that the hatching success rate is very low Store the eggs at a cool temperature 8 15 and at a relative air humidity of 75 If the hatching eggs have been sent you via post they should rest for at least 24 h before being plac...

Страница 5: ...arious poultry types and the required breeding temperatures Type of poultry Breeding temperature Chicken 37 4 37 6 Duck 37 4 37 6 Pigeon 38 5 Goose 37 6 Quail 37 6 37 8 Note A short drop in temperature whilst checking the eggs is usually not a problem for the embryos It is different with temperatures exceeding the recommended one These are harmful and even deadly and should be avoided at all costs...

Страница 6: ...s change the water surface in the incubator To increase the humidity and thus to enlarge the water surface place an additional container with water in the in cubator a few small moist sponges Alternatively the eggs can be sprayed with fine water mist To reduce the humidity decrease the water surface and use smaller containers Important Choose the shape and execution of the water containers keeping...

Страница 7: ...ugh the eggshell you can provide a starting aid by carefully opening the eggshell a little bit It is important to be cautious not to provide this aid too soon A lot of the times a wrong humidity can be reason as the egg membrane can dry and get stuck to the chick before it is able to get out of the egg Thus the chick cannot turn any longer and hatch out of the egg Note There has to be a sufficient...

Страница 8: ...nlay wet Do not keep the incubator open for too long when placing the bowl as this can have a nega tive impact on the hatching result Important Choose the shape and design of the water bowls making sure they do not pose a fatal risk to hatched chicks and reptiles After adjusting the according parameters of the incubator the eggs can be placed into the in cubator with the tip downward Set the numbe...

Страница 9: ... into the connection point to allow the incubator to function properly As soon as the incubator is connected it can be switched on and off via the button On the display there are multiple display areas 2 5 which show information on various parameters Additionally there are further symbols 1 6 7 8 on the display which show information on the pro cesses in the incubator Besides the display and the o...

Страница 10: ...button again the data will be saved The pre set temperature is 38 5 the basic temperature can be chosen between 30 and 39 5 3 Holding set for longer than 3 s This will open the menu for the finer parameter set tings see table 1 The individual parameter will show in the display with an alphanumerical combination parameter ID With the and buttons you can choose between the individual parameters If y...

Страница 11: ... when reaching the en tered value but will still radiate some warmth and the temperature might still rise a little bit in the incu bator E g this means that a tem perature of 38 can be reached when setting the temperature to 37 8 If you wish to avoid this the temperature of the heating stop needs to be corrected downward Table 1 Adjustment of the finer parameters via the set buttons 4 Reset Keep t...

Страница 12: ...lood dots which point to an early death of the embryo a Temperature of the incubator is too high or too low a Check the thermometers thermostat and the electricity follow the instructions of the manufacturer b See 1 g b See 1 g 3 Broken egg shells a See 2 a a See 2 a b Eggs were not turned properly b Turn the eggs frequently at least 4 5 times a day always turn them into the opposite direction c I...

Страница 13: ...r keep them for longer than ten to twelve days before breeding them only brood average sized eggs Troubleshooting technical problems Problem Possible reason Measures 1 The display has a loose contact does not shown anything a Plug is not connected properly to the incubator a Check the plug and push it into the incubator again b Plug is not connected properly to the socket b Reconnect the plug to t...

Страница 14: ...ountries with a separate collection system for these appliances The logo on the item or on its packaging points out that this item must not be treated as normal household waste but must be disposed of at a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this item you help protect the environment and the health of fellow human bein...