Fixing the weight balance (Fig. 1)
Figure 1
Insert the cable from the wide opening in the weight balance and pull it through
according to the needed switching height (water level).
Cable connection for automatic filling (Fig. 2, 3, 4)
Figure 2
Figure 3
Figure 4
Connect “blue” to the pump, “black” to the neutral conductor; “brown” is not used and must be
insulated.
As soon as the water level drops under the required minimum height, the switch starts the
pump. If the tank is full, the switch stops the pump. The height of automatic water level control
is set according to Fig. 3.
Automatic pumping out and water shortage protection (Fig. 5, 6, 7)
Figure 5
Figure 6
Figure 7
Connect “brown” to the pump, “black” to the neutral conductor; „blue“ is not used and must be
insulated.