WilTec 50593 Скачать руководство пользователя страница 2

The information contained in this document may alter at any time without previous notice. It is prohib-
ited to copy or spread any parts of this document in any way without prior written allowance. All rights
reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.

Send an e-mail to:

[email protected]

or use our contact form:

https://www.wiltec.de/contacts/

The most recent version of this manual in various languages can be found in our online shop via:

https://www.wiltec.de/docsearch

Our postal address is:

WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany

Do you wish to pick goods up? Our pick-up address is:

WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously
or placing your order via the webshop.

E-mail: [email protected]
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

To return orders for exchange, repair or for other purposes, please use the following address. Atten -
tion! To allow for a smooth execution of your complaint or return, it is important to contact our cus -
tomer service team before returning the goods.

Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler

E-mail: 

[email protected]

Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

© by WilTec Wildanger Technik GmbH 

Item 50593, 50598, 50599, 50629, 50630

Page 2

http://www.WilTec.de
http://www.aoyue.eu  

  

04 2021

-1

http://www.teichtip.de

Содержание 50593

Страница 1: ... operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ... be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placing your or...

Страница 3: ... 230 V AC specified on the nameplate of the float switch must correspond to the existing mains voltage Make sure that the electrical plug connections are protected from flooding and moisture Pull out the mains plug before starting any work The operator is responsible for compliance with location specific safety and installation regula tions You may ask a qualified electrician The user must take ap...

Страница 4: ...ata Item number 50593 50598 50599 50629 50630 Voltage V 230 Frequency 50 Max switching current A 16 Max voltage fluctuation 10 Switching angle 50 Temperature range 0 50 Protection class IP68 Cable cross section 3 0 5 Cable length m 10 5 10 5 2 Electrical connection The electrical connection is made to an earthed socket with 230 V 50 Hz protection at least 16 A Cleaning The float switch and the cab...

Страница 5: ...witch Cables that are not connected must be insulated The cable connections must not be immersed in water The connected pump must be earthed Dimensions Variant 1 Variant 2 by WilTec Wildanger Technik GmbH Item 50593 50598 50599 50629 50630 Page 5 http www WilTec de http www aoyue eu 04 2021 1 http www teichtip de ...

Страница 6: ...lated As soon as the water level drops under the required minimum height the switch starts the pump If the tank is full the switch stops the pump The height of automatic water level control is set according to Fig 3 Automatic pumping out and water shortage protection Fig 5 6 7 Figure 5 Figure 6 Figure 7 Connect brown to the pump black to the neutral conductor blue is not used and must be insulated...

Страница 7: ...ht it stops the pump and protects it against dry running Automatic filling and pumping out Fig 8 Figure 8 This circuit allows automatic filling and pumping out with two pumps by WilTec Wildanger Technik GmbH Item 50593 50598 50599 50629 50630 Page 7 http www WilTec de http www aoyue eu 04 2021 1 http www teichtip de ...

Страница 8: ...t this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Material recycling helps reduce the consumption of raw...

Отзывы: