Operation Manual

Float Switch

50593, 50598, 50599, 50629, 50630

Illustration similar, may vary depending on model

Read and follow the operating instructions and safety information before using for the first time. 

Technical changes reserved!
Due to further developments, illustrations, functioning steps and technical data can differ insignific-
antly.

Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

Содержание 50593

Страница 1: ... operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ... be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placing your or...

Страница 3: ... 230 V AC specified on the nameplate of the float switch must correspond to the existing mains voltage Make sure that the electrical plug connections are protected from flooding and moisture Pull out the mains plug before starting any work The operator is responsible for compliance with location specific safety and installation regula tions You may ask a qualified electrician The user must take ap...

Страница 4: ...ata Item number 50593 50598 50599 50629 50630 Voltage V 230 Frequency 50 Max switching current A 16 Max voltage fluctuation 10 Switching angle 50 Temperature range 0 50 Protection class IP68 Cable cross section 3 0 5 Cable length m 10 5 10 5 2 Electrical connection The electrical connection is made to an earthed socket with 230 V 50 Hz protection at least 16 A Cleaning The float switch and the cab...

Страница 5: ...witch Cables that are not connected must be insulated The cable connections must not be immersed in water The connected pump must be earthed Dimensions Variant 1 Variant 2 by WilTec Wildanger Technik GmbH Item 50593 50598 50599 50629 50630 Page 5 http www WilTec de http www aoyue eu 04 2021 1 http www teichtip de ...

Страница 6: ...lated As soon as the water level drops under the required minimum height the switch starts the pump If the tank is full the switch stops the pump The height of automatic water level control is set according to Fig 3 Automatic pumping out and water shortage protection Fig 5 6 7 Figure 5 Figure 6 Figure 7 Connect brown to the pump black to the neutral conductor blue is not used and must be insulated...

Страница 7: ...ht it stops the pump and protects it against dry running Automatic filling and pumping out Fig 8 Figure 8 This circuit allows automatic filling and pumping out with two pumps by WilTec Wildanger Technik GmbH Item 50593 50598 50599 50629 50630 Page 7 http www WilTec de http www aoyue eu 04 2021 1 http www teichtip de ...

Страница 8: ...t this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Material recycling helps reduce the consumption of raw...

Отзывы: