background image

 

© by WilTec Wildanger Technik GmbH 

 

Item 34244

 

Page 2 

 

http://www.WilTec.de

 

http://www.aoyue.eu

 

 

 

02 2022

-1

 

http://www.teichtip.de

 

 

The information contained in this document may alter at any time without previous notice. It is prohibited 
to copy or spread any parts of this document in any way without prior written allowance. All rights re-
served.

 

The  WilTec  Wildanger  Technik  GmbH  cannot  be  held  accountable  for  any  possible  mistakes  in  this 
operating manual, nor in the diagrams and figures shown.

 

Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure 
that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided.

 

If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing 
from you.

 

 

Send an e-mail to:

 

 

[email protected]

 

 

or use our contact form:

 

 

https://www.wiltec.de/contacts/

 

 

The most recent version of this manual in various languages can be found in our online shop via:

 

 

https://www.wiltec.de/docsearch

 

 
 

Our postal address is:

 

 

WilTec Wildanger Technik GmbH

 

Königsbenden 12

 

52249 Eschweiler

 

Germany

 

 

Do you wish to pick goods up? Our pick-up address is:

 

 

WilTec Wildanger Technik GmbH

 

Königsbenden 28

 

52249 Eschweiler

 

Germany

 

 

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously or 
placing your order via the webshop.

 

 

E-mail: [email protected]

 

Tel: +49 2403 55592–0

 

Fax: +49 2403 55592–15

 

 

To return orders for exchange, repair, or other purposes, please use the following address. Attention! 
To  allow  for  a  smooth  execution  of  your  complaint  or  return,  it  is  important  to  contact  our  customer 
service team before returning the goods.

 

 

Returns Department

 

WilTec Wildanger Technik GmbH

 

Königsbenden 28

 

52249 Eschweiler

 

 

E-mail: 

[email protected]

 

Tel: +49 2403 55592–0

 

Fax: +49 2403 55592–15

 

 

 

Содержание 34244

Страница 1: ...ating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...ervice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschw...

Страница 3: ...ly be carried out by an electrician The 230 V alternating voltage indicated on the type plate of the device must correspond to the existent mains voltage Never lift carry or fix the device by using the power cable Make sure that the electrical plug connection is protected from flood and moisture Disconnect the mains plug before starting the maintenance work at the compressor The user is responsibl...

Страница 4: ...tightened Do not use the compressor if it is damaged If the compressor generates unusual noises and strong vibrations or if other unusual signs occur that indicate some damage you should turn off the compressor immediately For repairs please use only original spare parts Do not make any technical modifications to the compressor In case you cannot eliminate the malfunction hand over the device to a...

Страница 5: ... all kinds of nozzles from 0 2 to 1 0 mm Notes The compressor has a 9 51 mm outlet male thread which can be effortlessly changed to The matching adapter is not included in the supply When the compressor is connected by the hose to the airbrush gun the compressor can be connected to the mains and be switched on The maximum pressure is displayed by the pressure gauge the operating pressure can be ad...

Страница 6: ... possible in order to avoid any impact on the capacity and efficiency of the compressor A leak causes the auto stop and auto start function to be carried out permanently Difference between maximum and operating pressure The maximum pressure is the highest possible pressure a compressor can generate Once the maximum pressure has been reached the compressor switches off auto stop As soon as the pres...

Страница 7: ...y click ing it into place Do not rotate the knob against high resistance If necessary the height and the position of the of the knob can vary slightly For emptying the condensed water collector use the water drain plug Exploded view and parts list Name Qty Name Qty 1 Screw 8 26 O ring 1 2 Pipe nut 2 27 Cylinder head 1 3 Block 1 28 Cap screw 4 4 Rear body 1 29 Filter valve 1 5 Screw 4 30 Handle 1 6...

Страница 8: ...ner ring 1 38 Connector 2 14 Compression ring 1 39 Connecting ring 1 15 Pipe 1 40 Adaptor 1 16 Adaptor 1 41 Screw 1 17 Cylinder 1 42 Tank 1 18 Valve plate 2 43 Drain valve 1 19 O ring 1 44 Safety valve 1 20 Screw 1 45 Adaptor 1 21 Front gasket 1 46 Fan 1 22 Front cover 1 47 Case 1 23 Filter 1 48 Cover 1 24 O Ring 1 49 Base 1 25 Cylinder block 1 50 Fan cap 1 ...

Страница 9: ...European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of you...

Отзывы: