Description of the pump

en

Installation and operating instructions Wilo-Yonos PICO1.0

5

2.2

Personnel qualifications

Personnel must:

ƒ

Be instructed about locally applicable regulations governing accident prevention.

ƒ

Have read and understood the installation and operating instructions.

Personnel must have the following qualifications:

ƒ

Electrical work: Electrical work must be performed by a qualified electrician.

ƒ

Installation/dismantling work: The installation/dismantling must be carried out by a
qualified technician who is trained in the use of the necessary tools and fixation ma-
terials.

ƒ

The product must be operated by persons who are instructed on how the complete
system functions.

Definition of “qualified electrician”

A qualified electrician is a person with appropriate technical education, knowledge and
experience who can identify 

and

 prevent electrical hazards.

2.3

Electrical work

ƒ

Electrical work must be performed by a qualified electrician.

ƒ

Nationally applicable guidelines, standards and regulations as well as specifications
issued by the local energy supply companies for connection to the local power sup-
ply system must be observed.

ƒ

Before commencing work, disconnect the product from the mains and secure it
against being switched on again.

ƒ

The connection must be secured by means of a residual-current device (RCD).

ƒ

The product must be earthed.

ƒ

Have defective cables replaced immediately by a qualified electrician.

ƒ

Never open the control module and never remove operating elements.

2.4

Operator responsibilities

ƒ

Have all work carried out by qualified personnel only.

ƒ

Ensure on-site guard against hot components and electrical hazards.

ƒ

Have defective gaskets and connection pipes replaced.

This device can be used by children from 8 years of age as well as people with reduced
physical, sensory or mental capacities or lack of experience and knowledge if they are
supervised or instructed on the safe use of the device and they understand the dangers
that can occur. Children are not allowed to play with the device. Cleaning and user
maintenance must not be carried out by children without supervision.

3

Description of the pump

High-efficiency circulator for hot-water heating systems with integrated differential
pressure control. Control mode and delivery head (differential pressure) are adjustable.
The differential pressure is controlled via the pump speed. For all control functions, the
pump continuously adapts to the system’s changing power requirements.

Содержание Yonos PICO1.0

Страница 1: ...Pioneering for You Wilo Yonos PICO1 0 4248347 Ed 01 2021 08 en Installation and operating instructions...

Страница 2: ......

Страница 3: ...cations control mode and functions 7 4 Application use 7 4 1 Intended use 8 4 2 Misuse 8 5 Transportation and storage 8 5 1 Scope of delivery 8 5 2 Transport inspection 8 5 3 Transport and storage con...

Страница 4: ...on carries the following risks Danger to persons from electrical mechanical and bacteriological effects as well as electromagnetic fields Environmental damage from discharge of hazardous substances Da...

Страница 5: ...t be observed Before commencing work disconnect the product from the mains and secure it against being switched on again The connection must be secured by means of a residual current device RCD The pr...

Страница 6: ...with LED display 7 LED display Display of operating statuses 8 Operating button Settings of all parameters 9 Wilo Connector Electrical mains connection 3 2 Operating and display elements Operating but...

Страница 7: ...Radiator heating system H max H H min Hs Q Hs 1 2 Recommended for two pipe heating systems with radiators to reduce the flow noise at thermostatic valves Variable differential pressure p v The pump re...

Страница 8: ...distance from the product Never allow unauthorised persons to carry out work Never operate the pump beyond the specified limits of use Never carry out unauthorised conversions Never operate with phase...

Страница 9: ...ation posi tion Fig 2 The motor must always be installed horizontally The electrical connection must never face upwards Fig 2 Installation positions Choose an installation point that is easily accessi...

Страница 10: ...hen installing the pump Note the direction of flow arrow on the pump housing 1 Install with horizontal glandless motor 2 without mechanical tension Place gaskets in the screwed connections Screw on th...

Страница 11: ...ary adjust the RCD accordingly Only operate the pump with sinusoidal AC voltage Observe the switching frequency Switch on off procedures via mains voltage 100 24 h 20 h for a switching frequency of 1...

Страница 12: ...oving the Wilo Connector Connecting the pump Earth the pump Connect the Wilo Connector to the control module until it snaps into place Fig 5f Activate the power supply Removing the Wilo Connector Disc...

Страница 13: ...delivery head are provided as a guide only A more detailed calculation for the setting is recommended The values of the delivery head are displayed in increments of 0 1 m with the setting 7 2 1 Radiat...

Страница 14: ...onnecting cables should always be repaired by a qualified electrician only WARNING Risk of scalding At high fluid temperatures and system pressures allow the pump to cool down first and then depressur...

Страница 15: ...temperature Module interior too warm Check conditions of use E36 Module defective Electronics defective Request customer service If the fault cannot be remedied contact a specialist technician or the...

Страница 16: ...elated Products and Energy Information Amendment EU Exit Regulations SI 2019 No 539 _ Restriction of the Use of Certain Hazardous Substances RoHS in Electrical and Electronic Equipment Regulations SI...

Страница 17: ...turer declare under our sole responsability that these glandless circulating pump types of the series Als Hersteller erkl ren wir unter unserer alleinigen Verantwortung da die Nassl ufer Umw lzpumpen...

Страница 18: ...ge side HR Hrvatski HU Magyar FI Suomen kieli GA Gaeilge EU EY VAATIMUSTENMUKAISUUSVAKUUTUS AE EC DEARBH COMHL ONTA Matala J nnite 2014 35 EU S hk magneettinen Yhteensopivuus 2014 30 EU Energiaan liit...

Страница 19: ...patybilno ci Elektromagnetycznej 2014 30 UE Produkt w zwi zanych z energi 2009 125 WE sprawie ograniczenia stosowania niekt rych niebezpiecznych substancji 2011 65 UE 2015 863 De producten voldoen eve...

Страница 20: ......

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: