background image

10

ENGLISH

and lift the module carefully from
the motor head.

Attach the clock module to the
base provided, push the provided
seal underneath the module
above the contact block and
press down as far as possible.
Put the pre-assembled module
into the contact chamber block of
the motor head, press it in secur-
ely. Ensure that the module is in
the correct position. Place the
earthing bar in the appropriate
opening 

(E

·

and screw in the

earthing screw. Screw the two
fastening screws alongside 

(E

·

)

and in the openings which are still
empty on the base. Tighten them
with a screwdriver.

Place the capacitor in the terminal
box cavity. Position the capaci-
tor’s connecting wires in such a
way that they can easily be put
into the two tip jacks (-

| |

-) Position

the wires neatly. Pass the network
cable through the PG threaded
joint and connect to the terminals

L, N,

and the earthing screw

(E

·

).

Tighten PC screw once again.

Position the module lid supplied
with the assembly set. Position
and tighten the fastening screws.

– Switch on mains supply again.

6 Starting up/Settings

Module can be operated by the
user!

The preset time is set using the
adjustable strips on the rim of the
switch clock between 
– pump mode (red area visible)
– pump shut-down (red area not

visible)

Setting the preset time 

(Fig. 10)

:

Open the transparent lid carefully
with a screwdriver.

– for the operating times, press the

adjustable strips on the rim of the
switch clock radially towards the
centre 

(1 adjustable strip = 

1

/

4

hour),

– Synchronise the switch clock with

the correct time of day. In order to
do so, turn the turn the rim of the
clock clockwise until the correct
time is directly under the arrow
marking.

Close transparent lid.

Subject to technical alterations!

Содержание Wilo-Steckmodul S1R-h Star-Z 20 Series

Страница 1: ...ckmodul S1R h Star Z 20 Z 25 Einbau und Betriebsanleitung Installation and Operating Instructions Notice de montage et de mise en service Istruzioni di montaggio uso e manutenzione D GB F I 2023859 2000 08 DDD ...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ...ion 11 4 Description du produit et accessoires 11 5 Montage Installation 12 6 Mise en service réglage 13 GB 1 General Information 8 2 Safety 8 3 Transport and interim storage 8 4 Product and accessory description 8 5 Assembly Installation 9 6 Starting up Settings 10 I 1 Generalità 14 2 Sicurezza 14 3 Trasporto e magazzinaggio 14 4 Descrizione del prodotto e accessori 14 5 Montaggio Installazione 1...

Страница 6: ... 336 CEE 92 31 CEE 93 68 CEE Normes utilisées harmonisées notamment EN 50 081 1 EN 50 082 1 NL EG verklaring van overeenstemming iermede verklaren wij dat deze machine voldoet aan de volgende bepalingen Elektromagnetische tolerantie 89 336 EEG 92 31 EEG 93 68 EEG Gebruikte geharmoniseerde normen in het bijzonder EN 50 081 1 EN 50 082 1 E Declaración de conformidad CE Por la presente declaramos que...

Страница 7: ...92 31 EWG 93 68 EWG Alkalmazott harmonizált normák különösen az EN 50 081 1 EN 50 082 1 CZ Osvûdãení o shodnosti s normami EU Prohla ujeme tímto Ïe toto zafiízení odpovídá následujícím pfiíslu n m ustanovením Elektromagneticá sná en livost 89 336 EHS vãetnû dodatkÛ 92 31 EHS 93 68 EHS PouÏité souhlasné normy zejména EN 50 081 1 EN 50 082 1 GR ήλωση συµµ ρφωσης µε τους κανονισµούς CE ηλώνουµε τι το π...

Страница 8: ...litet 89 336 EØF i denne udgave 92 31 EØF 93 68 EØF Anvendte harmoniserede normer især EN 50 081 1 EN 50 082 1 N EU overensstemmelseserklæring Det erklæres herved at dette utstyret stemmer overens med følgende bestemmelser Elektromagnetisk kompatibilitet 89 336 EEC og følgende 92 31 EEC 93 68 EEC Anvendte harmoniserte normer i særdeleshet EN 50 081 1 EN 50 082 1 TR Uygunluk Belgesi As ag í daki ci...

Страница 9: ...the range 10 C to 55 C ATTENTION 1 General Information Assembly and installation should only be carried out by qualified personnel Before attempting to assemble and start up this module these instruc tions should be read carefully Damage resulting from non obser vance of these instructions is not covered by our guarantee The safety instructions con tained in the pump s operat ing manual must be ob...

Страница 10: ...current and volt age of the mains supply Isolate the mains supply to the pump and secure against unau thorised switch on ATTENTION 5 2 Conversion instructions Fig 1 9 Before commencing work please ensure that the assembly set is complete Should any part be miss ing or broken please contact your nearest Wilo customer service Observe correct installation posi tion Turn the motor head through 180 whe...

Страница 11: ...es neatly Pass the network cable through the PG threaded joint and connect to the terminals L N and the earthing screw E Tighten PC screw once again Position the module lid supplied with the assembly set Position and tighten the fastening screws Switch on mains supply again 6 Starting up Settings Module can be operated by the user The preset time is set using the adjustable strips on the rim of th...

Отзывы: