background image

English

Installation and operating instructions Wilo-VeroLine-IPH-O, IPH-W

31

10

Faults, causes and remedies

Have faults remedied by qualified personnel only! Observe the 
safety instructions in chapter 9.2 “Disassembling and dismantling 
the pump” on page 13.

• If the malfunction cannot be rectified, consult a specialist techni-

cian or the nearest Wilo customer service or representative office.

11

Spare parts

Spare parts may be ordered via a local specialist and/or Wilo after-
sales service.

To avoid queries and incorrect orders, all data of the rating plate 
should be submitted for each order.

CAUTION! Risk of material damage!
Trouble-free pump operation can only be guaranteed when origi-
nal spare parts are used.

• Only use original Wilo spare parts.
• Each component is identified in the table below. 

Information to be provided when ordering spare parts:
• Spare part number 
• Name/description of the spare part
• All data on the pump and motor rating plate

Fault

Cause

Remedy

Pump does not start 
or stops working

Pump blocked

Disconnect motor from power supply, remove cause of 
blockage; if motor blocked, overhaul/replace motor/motor 
impeller unit

Cable terminal loose

Tighten all terminal screws

Fuses defective

Check fuses; replace faulty fuses

Motor damaged

Have the motor checked by Wilo customer service or a spe-
cialised service centre and serviced if necessary

Motor protection switch has 
triggered

Throttle the pump to the rated volume flow on the pressure 
side

Motor protection switch set 
incorrectly

Set the motor protection switch to the correct rated current 
as shown on the rating plate.

Motor protection switch 
affected by excessive ambient 
temperature

Move the motor protection switch or protect it using thermal 
insulation

Pump runs at reduced 
output

Incorrect direction of rotation

Check direction of rotation, change if necessary

Stop valve on the pressure side 
throttled

Slowly open the stop valve

Air in the suction line

Seal leaks at the flanges; vent

Pump making noises

Insufficient supply pressure

Increase supply pressure, observe minimum pressure at the 
suction port, check slide valve and filter on the suction side 
and clean if need be

Motor has bearing damage

Have the pump checked by Wilo after-sales service or a spe-
cialised service centre and repaired if necessary

Содержание VeroLine IPH Series

Страница 1: ...IPH O IPH W Pioneering for You 2 140 983 Ed 01 2013 10 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bediening...

Страница 2: ...Fig 1 Fig 2 Fig 3...

Страница 3: ...Fig 4 1 2 3 1 2 3 3 6 3 5 2 2 1 3 3 2 3 3 3 4 6 3 6 2 6 1 1 2 2 2 2 3 3 2 3 3 3 4 7 3 5 6 8 9 10 4 1 1 1 2 1 2 2 2 1 2 4 2 2 2 3...

Страница 4: ......

Страница 5: ...de Einbau und Betriebsanleitung 3 gb Installation and operating instructions 19 fr Notice de montage et de mise en service 35 nl Inbouw en bedieningsvoorschriften 51...

Страница 6: ...erim storage 21 3 1 Shipping 21 3 2 Transport for installation dismantling purposes 21 4 Intended use 22 5 Product information 22 5 1 Type key 22 5 2 Technical data 23 5 3 Scope of delivery 23 5 4 Acc...

Страница 7: ...ting instructions on product personnel safety are not observed this declaration loses its validity 2 Safety These operating instructions contain basic information which must be adhered to during insta...

Страница 8: ...ng and safety regulations of the operator are to be complied with 2 5 Safety instructions for the operator This appliance is not intended for use by persons including children with reduced physical se...

Страница 9: ...l under or exceed those specified in the catalogue data sheet 3 Transport and interim storage 3 1 Shipping The pump is enclosed in a box or lashed to a pallet ex works and is pro tected against dirt a...

Страница 10: ...its Contraindications Typical installation locations are technical rooms within the building with other domestic installations Installing the device directly in other used rooms residential and work r...

Страница 11: ...cessories must be ordered separately PTC thermistor tripping unit for switch cabinet installation For a detailed list consult the catalogue price list Property Value Remarks Rated speed 2900 or 1450 r...

Страница 12: ...ury Failure to install safety devices on the motor terminal box or on the coupling can cause electrical shock or contact with rotating parts potentially resulting in life threatening injuries Before c...

Страница 13: ...hich accumulates in the lantern can be discharged spe cifically via the existing holes The lantern has an opening on the underside which allows a drain pipe for condensation water to be con nected The...

Страница 14: ...3 mm in accordance with VDE 0730 Part 1 in Germany The connection line is to be installed in such a way that it cannot under any circumstances come into contact with the pipe and or the pump and motor...

Страница 15: ...oupling covers that were removed must be reinstalled Keep a safe distance during commissioning Always wear protective clothing protective gloves and protective goggles when working WARNING Risk of bur...

Страница 16: ...a minimum volume flow of 10 15 of the pump s rated volume flow must be guaranteed NOTE When pumping out of a tank ensure that the liquid level is always high enough above the suction port of the pump...

Страница 17: ...system pressures allow the pump to cool down before all work Always wear protective clothing protective gloves and protective goggles when working 9 1 Mechanical seal The mechanical seal is maintenan...

Страница 18: ...ctions in conjunction with the work described in the following Observe the screw tightening torque for the thread type see section Screw tightening torques on page 14 NOTE If you replace the mechanica...

Страница 19: ...supply remove cause of blockage if motor blocked overhaul replace motor motor impeller unit Cable terminal loose Tighten all terminal screws Fuses defective Check fuses replace faulty fuses Motor dama...

Страница 20: ...2 Disc 2 3 Nut 3 1 Cooling housing 3 2 Circlip 3 3 Retaining ring 3 4 O ring 3 5 O ring 3 6 Screw 4 Motor 5 Mechanical seal set Nut 6 Intermediate piece set with Locking disc 1 2 Flat gasket 2 2 Disc...

Страница 21: ...equires the product to be drained and cleaned Lubricants must be collected The pump components are to be sepa rated according to material metal plastic electronics 1 Use public or private disposal org...

Страница 22: ......

Страница 23: ...rective 2006 95 EC are realized according annex I No 1 5 1 of the EC Machinery directive 2006 42 EC Les objectifs protection de la directive basse tension 2006 95 CE sont respect es conform ment appen...

Страница 24: ...o strojn ch za zen ch 2006 42 ES Przestrzegane s cele ochrony dyrektywy niskonapi ciowej zgodnie z za cznikiem I nr 1 5 1 dyrektywy maszynowej 2006 42 WE I 1 5 1 2006 42 G Sm rnice o elektromagnetick...

Страница 25: ...O Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 Ireland WILO Ireland F T 353 61 227566 Italy Borromeo Milano T 39 25538351 Kazakhstan WILO Central Asia 050002 Almaty T 7 727 2785961 F Korea z...

Страница 26: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: