Wilo Rexa MINI3-S Скачать руководство пользователя страница 13

en

Installation and operating instructions • Wilo-Rexa MINI3-S • Ed.01/2022-03

13

9.

Clean the screw plug, replace the seal ring with a new one and
fully screw it in.

10.3

General overhaul

Have the customer service team check the pump after 1,500 oper-
ating hours. All components will be checked for wear and damaged
components will be replaced.

11

Faults, causes and remedies

Pump not starting or switches off after a short time

1.

Interrupted power supply

Check the electrical connection of the pump.

Have a qualified electrician check fuses/residual-current
devices.

2.

Thermal motor monitoring has been tripped

Allow the pump to cool down. The pump will start auto-
matically.

Pump switches on/off too frequently. Check the switching
cycle of the float switch.

Excessive fluid temperature. Check the temperature. If ne-
cessary, use a different pump.

3.

Suction port/strainer/impeller silted/clogged

Shut down the pump, remove it and clean it.

4.

Float switch not operational

The float switch must be able to move freely.

Pump starts up, but does not supply fluid

1.

Pressure pipe/discharge pipe clogged

Flush out the pressure pipe.

Flush out the pressure hose.

Remove any kinks in the pressure hose.

2.

Swing check valve contaminated

Shut down the pump, remove it and clean the discharge
connection.

Replace faulty swing check valve.

3.

Water level too low

Check inlet.

Pump is pumping at a too low level. Check the switching
cycle of the float switch.

4.

Suction port/strainer silted/clogged

Shut down the pump, remove it and clean it.

5.

Air in the pump/pressure pipe

Position the pump at a slight angle to allow air to escape.

Install a bleed unit in the pressure pipe.

Delivery rate drops while the pump is running

1.

Pressure pipe/discharge pipe clogged

Flush out the pressure pipe.

Flush out the pressure hose.

Remove any kinks in the pressure hose.

2.

Suction port/strainer silted/clogged

Shut down the pump, remove it and clean it.

3.

Air in the pump/pressure pipe

Position the pump at a slight angle to allow air to escape.

Install a bleed unit in the pressure pipe.

4.

Signs of wear

Contact customer service.

Customer service

If the points listed here do not rectify the fault, contact customer
service. Costs may be incurred when using customer service sup-
port! Please contact customer services for more information.

12

Spare parts

Spare parts are ordered via customer service. To avoid return quer-
ies and incorrect orders, the serial or article number must always be
supplied. 

Subject to change without prior notice!

13

Disposal

13.1

Information on the collection of used electrical and
electronic products

Proper disposal and appropriate recycling of this product prevents
damage to the environment and danger to your personal health.

NOTICE

Disposal in domestic waste is prohibited!

In the European Union this symbol may be included
on the product, the packaging or the accompanying
documentation. It means that the electrical and
electronic products in question must not be dis-
posed of along with domestic waste.

To ensure proper handling, recycling and disposal of the used
products in question, please note the following points:

Hand over these products at designated, certified collection
points only.

Observe the locally applicable regulations!

Please consult your local municipality, the nearest waste disposal
site, or the dealer who sold the product to you for information on
proper disposal. See www.wilo‑recycling.com for more information
about recycling.

13.2

Oil

WARNING

Risk of environmental and health damage
due to incorrect disposal of oils!

Oil is harmful to health and the environment! Do not
dispose of oil with domestic waste or in the sewage
system! Collect the oil in a sealable, oil-resistant
container and dispose of it at a certified collection
point.

Содержание Rexa MINI3-S

Страница 1: ...Pioneering for You Wilo Rexa MINI3 S 6092615 Ed 01 2022 03 en Installation and operating instructions...

Страница 2: ...Rexa MINI3 S http qr wilo com 413 Rexa MINI3 https qr wilo com 405...

Страница 3: ...n 6 2 2 Technical data 7 2 3 Type key 7 2 4 Scope of delivery 7 2 5 Functions 7 3 Application use 7 3 1 Intended use 7 3 2 Improper use 7 4 Transport and storage 7 5 Installation and electrical connec...

Страница 4: ...in grey Damage to property Safety instructions start with a signal word and are displayed without a symbol Signal words DANGER Failure to follow the instructions will result in serious injuries or de...

Страница 5: ...5 A2 1 8 Transport and storage Wear protective equipment Always carry the product by the handle Clean product and disinfect if necessary Dirt fosters the formation of germs Encrustations may lead to t...

Страница 6: ...ct customer service If the seal is defective the oil enters the pumped fluid and the sewer Collect waste oil by type unmixed and dis pose of it in accordance with regulations at a certified collection...

Страница 7: ...ins frequency 5 50 Hz 6 60 Hz 23 Rated voltage code A Additional electrical equipment O with bare cable end P with plug CEE 7 7 A with float switch and plug CEE 7 7 2 4 Scope of delivery Pump Installa...

Страница 8: ...valve non return valve Lay the discharge pipe frost proof Air pockets in the pump and in the discharge pipe can lead to delivery problems Installing the ventilation systems E g Air vent valve In the...

Страница 9: ...ng This causes the air to escape from the pump 7 Route the connection cable to the socket power supply Pump is installed 5 3 Electrical connection Mains connection with correctly installed protective...

Страница 10: ...itch The minimum requirement is a thermal relay motor protection switch with temperature compensation differential trip and re activation lock according to local regulations Set the motor protection s...

Страница 11: ...week repeat the test run every month 6 4 During operation CAUTION Do not allow the pump to dry run Do not run the pump without fluid dry run Switch off the pump once the residual water level has been...

Страница 12: ...ilable 1 Ensure that the plug or bare cable end is packed and stored in a watertight manner 2 Rinse the pump and cable under clean running water 3 To clean the inside of the pump guide the water jet i...

Страница 13: ...e pressure hose Remove any kinks in the pressure hose 2 Suction port strainer silted clogged Shut down the pump remove it and clean it 3 Air in the pump pressure pipe Position the pump at a slight ang...

Страница 14: ......

Страница 15: ......

Страница 16: ...Pioneering for You Local contact at www wilo com contact WILO SE Wilopark 1 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: