38
Wilo SE 06/2020
en
• Install shut-off devices upstream and downstream of
the pump to facilitate pump replacement.
• Align the upper shut-off device laterally.
• When installing in the feed of open systems, the
safety supply must branch off upstream of the
pump (EN 12828).
• Complete all welding and brazing work.
• Flush the pipe system.
• Do not use the pump to flush the pipe system.
Installing the pump
Observe the following points when installing the pump:
• Note the direction arrow on the pump housing (1).
• Install glandless motor (2) horizontally, without
mechanical tension.
• Place gaskets in the screwed connections.
• Screw on threaded pipe unions.
• Use an open-end wrench to secure the pump against
twisting and screw tightly to piping.
• Re-mount the thermal insulation shell if required.
CAUTION!
An incorrect installation position may damage the pump.
• Select the installation point in line with the permis
-
sible installation position (Fig. 2).
• The motor must always be installed horizontally.
• The electrical connection must never face upwards.
CAUTION!
Leaking water may damage the control module.
• Align the upper shut-off device so that leaking
water cannot drip onto the control module (5).
• If the control module is sprayed with liquid, the sur
-
face must be dried off.
1
3
2
Содержание Para STG
Страница 2: ...Fig 1 12 1 3 4 5 Para STG 6 8 9 10 7 11 2...
Страница 3: ...Fig 2 Fig 3 a b Fig 4 Fig 5a Fig 5b 1 2 PE N L...
Страница 4: ...Fig 5c Fig 5d Fig 5e Fig 5f Fig 6...
Страница 6: ......