8. Faults, causes, remedies
WARNING! Switch the pump OFF before doing
any work on it!
9. Spare parts
All spare parts must be ordered through the Wilo
customer service.
Please state all data shown on the rating plate
with each order to avoid queries and incorrect
orders.
Faults
Causes
Remedies
Pump is running but does not deliver
Internal parts are obstructed by foreign
bodies
Dismantle the pump and clean it
Suction pipe obstructed
Clean all the pipes
Air in suction pipe
Check the tightness of the whole pipe up
to the pump, and tighten it
The pump is empty
Fill the pump in to prime it again
Suction pressure is too low; this is gene-
rally accompanied by cavitation noises
Loss of suction head or suction head is
too large
Supply voltage to the motor is too low
Check the voltage at the terminals of
the motor and the cross-sections of the
conductors
Strainer is not immersed
Immerse the strainer (min. 20 cm). Ballast
the flexible pipe if necessary
Pump vibrates
Loose on its foundation
Check the screws of the stud bolts and
tighten them completely
Pump is obstructed by foreign bodies
Dismantle the pump and clean it
Pump is hard to turn
Check if the pump turns freely without
abnormal sticking (pump stopped)
Incorrect electrical connection
Check the connections to the pump
Pump overheats
Voltage too low
Check the voltage on the motor termi-
nals; it should be within ± 10 % (50 Hz)
Pump is obstructed by foreign bodies
Dismantle the pump and clean it
Ambient temperature above +40°C
The motor is designed to operate at an
ambient temperature of not more than
+40°C
Altitude > 1000 m
Motor is designed to operate at an alti-
tude ≤ 1000
Motor does not run
No current
Check the electrical power
Hydraulic part blocked
Clean the pump
Thermal sensor release
Let the motor cool down
Pump delivers insufficient pressure
The motor fails to run at its normal
speed (foreign bodies, defective power
supply, etc.)
Dismantle the pump and correct the
problem
The motor is faulty
Replace it
Wearing of the internal elements
Replace them
The flow is irregular
The suction head (HA) is exceeded
Reread the installation conditions and
recommendations in this data sheet
The diameter of the suction pipe is
smaller than that of the pump
The suction pipe must have the same
diameter as the pump’s suction port
The strainer and suction pipe are
partially obstructed
Remove and clean it
WILO SE 02/2018
Содержание Initial JET
Страница 2: ...Fig 1 HA 0 5 M MIN MIN 200mm MIN 100 mm 1 2 3 6 5 7 4 0 5 m MIN...
Страница 29: ...29 1 1 1 2 2 1 2 2 2 3 2 4 2 5 Wilo Initial JET...
Страница 30: ...30 IEC VDE 2 6 2 7 2 8 4 3 4 4 1 4 2 1 1 1 mm 2 3 4 5 6 HA 4 3 4 4 2 WILO SE 02 2018...
Страница 32: ...32 6 ATEN O 6 1 1 3 2 4 0 5 6 2 5 800 13 7 5 4 WILO SE 02 2018...
Страница 33: ...33 8 200 mm 10 50 Hz 40 C 40 C 1 000 1 000 Wilo Initial JET...
Страница 34: ...34 9 10 www wilo recycling com WILO SE 02 2018...
Страница 52: ...52 1 1 1 2 2 1 2 2 2 3 2 4 2 5 WILO SE 02 2018...
Страница 55: ...55 8 9 Wilo 20 10 50 40 C 40 C 1000 1000 Wilo Initial JET...
Страница 56: ...56 10 www wilo recycling com WILO SE 02 2018...
Страница 61: ......
Страница 62: ......