Wilo Economy MHI 16 Series Скачать руководство пользователя страница 11

English

16

6. Commissioning

•  Check that there is a sufficient level of water in 

the reservoir and/or check the inlet pressure.

WARNING!   The pump must not run dry, as this 

  would destroy the axial face seal.

•  When used for the first time, if it is to be used to 

pump drinking water the system must be flushed 

through, so that any dirty water present will not 

contaminate the drinking water supply.

•  Checking direction of rotation (only for rotary 

current motors): Check that the pump rotates in 

the direction indicated by the arrow on the pump 

casing by switching on for a short time. If this is 

not the case, interchange 2 phases in the pump 

terminal box.

•  Only for rotary current motors: Adjust the motor 

cut-out to the nominal current given on the ra-

ting plate.

•  If available, position float switches or electrodes 

for protection against low water levels in such a 

way that the pump cuts out if the water level is 

so low that air would begin to be sucked in.

•  Open the isolating valve at the inlet, open the 

vent screw (Figs 1 & 2, 3, SW 19) until the pum-

ped fluid comes out, close the vent screw, open 

the isolating valve at the outlet and switch on the 

pump.

•   Depending on the fluid temperature and the sys-

tem pressure, if the vent screw is completely loo-

sened hot liquid or gas can escape or even shoot 

out at high pressure. 

Beware of scalding.

•   Depending on the operating conditions of the 

pump or installation (fluid temperature), the  

entire pump may be come very hot. 

Avoid  

touching the pipe owing to the risk of burning.

WARNING!

  The pump must not run for longer 

  than 10 minutes with a flow rate 

of Q = 0 m

3

/h. We recommend that when running 

continuously the pump should be kept at a mini-

mal flow of 10 % nominal flow.

7. Maintenance

•  The pump is almost maintenance free.

•  During the running-in period, there may be some 

dripping from the axial face seal. Should a more 

significant leak occur as a result of substantial 

wear, have the axial face seal replaced by a  

specialist.

•  Increased bearing noise and unusual vibrations 

indicate a worn bearing. In this case, have the be-

aring replaced by a specialist.

•  Before carrying out any maintenance work, 

switch off the pump and ensure that it cannot be 

switched on again by unauthorized people. Never 

carry out work on a running pump.

•  When the pump is exposed to frost or is out of 

service for a long period, the pump and pipework 

must be emptied in the cold season. Empty the 

pump by releasing the drain valve (Figs 1 & 2, 4), 

the inlet pipe by releasing the vent screw, and 

the outlet pipe by opening the bleeding point.

Figures:

1  Cross-section of the pump with reference numbers.
2.  Positioning and pipework of the pump.
3.  Drawing showing dimensions.
4.  Plan of electrical connections.

WILO SE 04/2016

Содержание Economy MHI 16 Series

Страница 1: ...en service nl Inbouw en bedieningsvoorschriften es Instrucciones de instalaci n y funcionamiento it Istruzioni di montaggio uso e manutenzione fi Asennus ja k ytt ohje sv Monterings och sk tselanvisni...

Страница 2: ......

Страница 3: ...MHI 2 4 8 16 Fig 1 Fig 2...

Страница 4: ...Fig 3 Y HIGH VOLTAGE LOW 3 1 1 Fig 4...

Страница 5: ...4 es Instrucciones de instalaci n y funcionamiento 30 it Istruzioni di montaggio uso e manutenzione 36 fi Huolto ja k ytt ohje 42 sv Monterings och sk tselinstruktioner 48 hu Be p t si s zemeltet si u...

Страница 6: ...eme in der Ver fah renstechnik K hlwasserkreisl ufe Feuer l schsysteme sowie Wasch und Beregnungsanla gen Wenn aggressive chemische Fl ssigkeiten gef r dert werdensollen istzuvordieZustimmungdesHer st...

Страница 7: ...d pump in industrial circulation systems in process techno logy in cooling water systems in fire extinguishers and in washing and sprinkler installations Approval from the manufacturer must be obtaine...

Страница 8: ...3 216 192 90 90 Rp1 158 Rp1 206 277 104 104 472 472 224 206 90 90 Rp1 182 Rp1 402 205 88 88 375 375 216 192 90 90 Rp11 4 110 Rp1 403 205 88 88 375 375 216 192 90 90 Rp11 4 110 Rp1 404 253 88 88 423 42...

Страница 9: ...only be carried out with the manufacturer s consent The use of original spare parts and accessories autho rized by the manufacturer will ensure safety The use of other parts may invalidate claims invo...

Страница 10: ...ation Electricalworkmustbecarriedoutbyaqualifiedand licensed electrician in strict compliance with local regulations The electricity supply must be connected via a rigid supply cable fitted with a cou...

Страница 11: ...r gas can escape or even shoot out at high pressure Beware of scalding Depending on the operating conditions of the pump or installation fluid temperature the entire pump may be come very hot Avoid to...

Страница 12: ...arrow fit a larger inlet pipe Pump does not pump evenly inlet too high position the pump lower Pressure is insufficient wrong choice of pump fit a more powerful pump wrong direction of rotation interc...

Страница 13: ...rmonisierten europ ischen Normen comply also with the following relevant harmonized European standards sont galement conformes aux dispositions des normes europ ennes harmonis es suivantes EN 60034 1...

Страница 14: ...9 125 EK 2006 42 2014 30 2009 125 EO WILO SE prohla uje e v robky uveden v tomto prohl en odpov daj ustanoven m n e uveden ch evropsk ch sm rnic a n rodn m pr vn m p edpis m kter je p ej maj Stroje 20...

Страница 15: ...prodotti spe ifikati f din id dikjarazzjoni huma konformi mad direttivi Ewropej li jsegwu u mal le islazzjonijiet nazzjonali li japplikawhom WILO SE verklaart dat de in deze verklaring vermelde produc...

Страница 16: ......

Страница 17: ...2785961 info wilo kz Korea WILO Pumps Ltd 618 220 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229 info wilo lv Lebanon WILO LEBANON SARL Jdeideh 1202 2...

Страница 18: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Отзывы: