background image

Centrum SV... DV... TV...

EN 

Installation and operating instructions

29993227

Centrum SV406

29993228

Centrum SV408

29993229

Centrum SV605

29993230

Centrum SV608

29993231

Centrum SV1004

29993232

Centrum SV1006

29993233

Centrum DV406

29993234

Centrum DV408

29993235

Centrum DV605

29993236

Centrum DV608

29993237

Centrum DV1004

29993238

Centrum DV1006

29993239

Centrum TV406

29993240

Centrum TV408

29993241

Centrum TV605

29993242

Centrum TV608

29993243

Centrum TV1004

29993244

Centrum TV1006

CD_TE062 rev00

Содержание 29993227

Страница 1: ...V608 29993231 Centrum SV1004 29993232 Centrum SV1006 29993233 Centrum DV406 29993234 Centrum DV408 29993235 Centrum DV605 29993236 Centrum DV608 29993237 Centrum DV1004 29993238 Centrum DV1006 2999323...

Страница 2: ...3 1 Fault Contacts 4 4 3 2 Low Water Cut Protection 4 4 3 3 Dry Run Protection 5 4 3 4 Master Slave Function 2 3 pump only 5 5 Installation 5 1 Local 5 5 2 Hydraulic Connections 5 5 3 Electrical Conn...

Страница 3: ...entioned 2 2 Risks Incurred by Failure to Comply Failure to comply with the safety precautions could result in personal injury or damage to the pump or installation It could also invalidate any claims...

Страница 4: ...ows down to a complete stop 4 2 3 Automatic Mode 3 Pump Only All controls and settings on a 3 pump set are done via the Speedcentre controller Fig 3 and are communicated to the drives Settings can be...

Страница 5: ...below Fig 5 The incoming mains connection must comply with local regulations As a protection measure the booster must be earthed according to the regulations i e according to the local regulations an...

Страница 6: ...tions The full warranty document is downloadable at www wilo co uk click on local information then downloads Before requesting a site visit the following information must be available to the service t...

Страница 7: ...nic Control Drive Fig 3 Speedcentre 3 pump only Manual Mode Inverter On Green LED Automatic Mode Alarm Red LED Menu Pump Running Yellow LED Enter Pump in Automatic Mode Green LED Value Setting Up Valu...

Страница 8: ...8 Fig 5 1 Wiring Schematics 1 Pump System Fig 4 Pump Schematics...

Страница 9: ...9 Fig 5 2 Wiring Schematics 2 Pump System...

Страница 10: ...10 Fig 5 3 Wiring Schematics 3 Pump System...

Страница 11: ...running hours Hrs Pump Cycles Total number of pump cycles one cycle one run and stop Power On Number of times the drive has been powered on Max Pressure Maximum pressure of the installation Bar Short...

Страница 12: ...OVER T If the temperature is too high the controller will stop the motor from running Check that the water temperature does not exceed 40 C Check that the ambient temperature does not exceed 50 C E02...

Страница 13: ...Pumps not primed Check that the suction strainer does not let air in or the tank filling point is too close from the strainer A pump is obstructed by particles Have the pump dismantled and cleaned Vo...

Страница 14: ...V406 1 16 E KS 400 50 4193858 HELIX V408 1 16 E KS 400 50 4156034 HELIX V605 1 16 E KS 400 50 4156038 HELIX V608 1 25 E KS 400 50 4150543 HELIX V1004 1 16 E KS 400 50 4150546 HELIX V1006 1 16 E K 400...

Страница 15: ...netic Compatibility Directive WEEE Directive ROHS Directive As well as following harmonized standards If the above mentioned series are technically modified without our approval this declaration shall...

Страница 16: ...Wilo UK LTD Second Avenue Centrum 100 Burton on Trent Staffordshire DE14 2WJ T 44 0 1283 523000 E sales uk wilo com www wilo com gb en Copyright Wilo UK LTD 2020...