background image

 

 

 

 

EC 

– Declaration of Conformity

 

 

according to machine directive 2006 / 42 / EEC

 

 
 

appendix II A

 

 
 
    Structure of the machine

 

    

 

    

Mobile oil-fired heaters ( with and without heat exchanger )

 

 
 
     Description:

 

 
     BV 385 

 

     

 

 

is designed, constructed and manufactured in accordance with the above-       
mentioned directive and the low voltage directive 2014 / 35 / EEC and also 
EMV 2014 / 30 EEC.   

 

     

 

     The following harmonized standards have been used:

 

 
     

- DIN EN 6100-3-2 

 

Electromagnetic compatibility 

    

 - EN  55011 

 

 

Product standard for wideband interferences

 

     - DIN EN ISO 12100 

 

Safety of machinery 

     - DIN EN 60335-1 

 

Safety of electrical appliances

 

  

     - DIN EN ISO 13857 

 

Safety of machinery, safety distances  

      

 

Note: The observance of DIN EN ISO 13857 refers only to the protection against 
accidental contacts of the fan. For the complete fulfillment of EN 13857 the user 
resp. installer is responsible.

 

  

 

 

               

 

The following national standards, directives and specifications have been   
used:

 

 

 

DIN EN 13842 „Mobile oil-fired heaters ( with and without heat exchanger )“

 

 

                   

 

 

  

      Mönchengladbach,

 

 

                   17.04.2020                                                                                         Managing Director

 

                   ______________                  ______________________            ____________________________  

 

                   Place, Date                             Signature                   

 

 

Содержание 1251385

Страница 1: ...Operating Manual Oil Fired Heaters BV 385 Perfection is our aim...

Страница 2: ...roduct standard for wideband interferences DIN EN ISO 12100 Safety of machinery DIN EN 60335 1 Safety of electrical appliances DIN EN ISO 13857 Safety of machinery safety distances Note The observance...

Страница 3: ...devices 5 Combi control 5 Room thermostat 5 4 Transport 5 5 Cleaning 5 6 Trouble shooting 6 7 Important notice for set up 7 8 Length and diameter of fuel lines 8 9 Service position 9 10 Nozzle change...

Страница 4: ...plug into the socket switch to position Heizen Heating and set the room thermostat to a low temperature frost protection 230 V only When ordering spare parts please give the type serial number of the...

Страница 5: ...n of the room The heater may not be worked on or transported during operation If the heater is used for drying of grain the set up has to be in a right angle in front of the radial fan or alternativel...

Страница 6: ...ection IP 44 Capacity kW 110 kcal h 94 600 Air volume m h 8 200 Max fuel consumption appr kg h 9 2 Dimensions L mm 1985 W mm 895 H mm 1385 Weight kg 305 Cone mm 520 Chimney mm 200 Photo cell standard...

Страница 7: ...he first starting During this time the oil is preheated so that the sorting out of paraffine is avoided Start the heater only with connected fuel hoses Otherwise the fuel pump will be destroyed During...

Страница 8: ...on and the postpurge of the fan The second sensor controls the operation temperature If the max operating temperature of 80 C is exceeded the sensor shuts the burner off while the fan continues to run...

Страница 9: ...ntake and shutts off The red lamp return line lights up Air bubbles in the Check oil level in tank suction line Check if the valve at the fuel filter is opened Push reset button On initial start the b...

Страница 10: ...the regulations or an installed exhaust pipe as shown in the drawing Never start the heaters connected to just an exhaust pipe which has been lead through the wall Use it only with an additional exhau...

Страница 11: ...meter of fuel lines The table refers to Heiz l EL 4 3 cST and inside diameter of the fuel lines In regard of the length of the fuel lines 4 elbows 1 valve and 1 relief valve were considered for the re...

Страница 12: ...the housing 10 Change of nozzle Disconnect ignition wire from the electrode Disconnect baffle plate and pull upside Loosen nozzle spanner SW 16 and secure nozzle block with a spanner SW 19 against tur...

Страница 13: ...g to the heater set up In order to reach equal combustion values we recommend the use of a draught regulator Measurement A The measurement A refer adjustment table serves as assistance for the burner...

Страница 14: ...xhausts CO O 2 9 CO from O 13 2 CO ppm 0 NOx ppm 87 0 CO mg kWh NOx mg kWh Soot Ba 0 1 Temperature Exhaust C 220 1 Ambient C 23 7 Combustion chamber C Various informations Pressure baffle plate hPa 4...

Страница 15: ...01 21 6162821 Special Room Thermostat for high humidity with cable and plug 01 22 6162616 Power Cord with Plug 01 23 6162812 Preheater 01 24 6162813 Oil Preheating Spiral 01 25 6162808 Quick Coupling...

Страница 16: ...O N Qty 45 6162841 Screwing 02 46 6162842 T Bar 02 47 6162674 Hose Nipple 02 48 6162843 Red Piece 02 49 6162845 Valve 01 50 6162846 Clamp 01 51 6162847 Clamp 02 52 6162848 Bypass Hose 01 53 6162430 C...

Страница 17: ...Exploded View BV 385 14 of 17...

Страница 18: ...rner 01 09 6163979 Housing without Suction Absorber 01 12 6163980 Pressure Pipe Pump Nozzle Plate 01 14 6163981 Fan Wheel 01 16 6162710 Suntec Pump AS 47 D 01 17 6162751 Fuel Hose 750 mm 02 18 6162644...

Страница 19: ...16 of 17...

Страница 20: ...17 of 17...

Отзывы: