Page 14
Rev. 1/2019
www.willoughby-ind.com
Installation & Operation Manual
Aquafount
®
180° Washfountain
WAF-5403 Series / WAF-5404 Series
Willoughby Industries, Inc.
TOLL FREE
(800) 428-4065
● LOCAL
(317) 875-0830
● FAX
(317) 875-0837
Installation Instructions (cont.)
SECURITY SCREWS
SHIPPING BOLTS
ACTUATOR HOUSING
BASIN
(SUPPLIED BY OTHERS)
WALL ANCHORS
PEDESTAL
1/4-20 X 1/2" PHILLIPS
TRUSS HEAD SCREWS
TOP LEDGE
Step 2: Mounting Basin
Parts supplied:
• Solid Surface Basin
• Actuator Housing
•
Pedestal Backplate
Removing the top cover.
Mounting the basin and actuator housing to
the backplate and wall.
1�)
Remove top cover from the valve head kit by loosening the security screws as shown in the
above-left diagram� Set the top cover, screws, and nuts aside�
2�) With the help of an assistant, place basin on top ledge of the pedestal assembly�
3�)
Carefully mark mounting holes on wall through the basin, then remove the basin and drill the
mounting holes�
4�)
Replace the basin and valve head kit as shown in the above-right diagram.
5�)
Fasten wall anchors (supplied by others) through the basin and valve head kit holes securely,
but
DO NOT OVERTIGHTEN
; this can damage the solid surface basin and valve head kit.
6�)
Secure the basin to the pedestal by fastening the1/4-20 x 1/2" Philips truss head screws up
through the pedestal basin mounting ring into the threaded inserts on the bottom of the basin�
Note: BE SURE to use the truss head screws included with the washfountain. Using
longer screws than those provided can damage the solid surface basin.