5. DIMENSIONS AND RATINGS (continued)
Table 11: Model PLB-098 & PLB-098-VS Burner data
Model
Input
BTU/h
(*)
Firing rate
USGPH
(*)
AFUE
(***)
Nozzle
(Delavan)
(**)
Pump
pressure
(PSIG)
(*)
Head
Low firing
rate baffle
Burner tube
insertion
length (Inch)
Static
disc
ATC
Head/Air
setting
77,000
0.55
85.7%
0.50 - 60A
150
6/0
98,000
0.70
85.1%
0.60 - 60W
140
10/3
77,000
0.55
85.7% ‡
0.50 - 60W
150
6/0
98,000
0.70
85.1% ‡
0.60 - 60W
140
10/3
AFG70MQSS
2 - Slot
L2
1 3/4"
BECKET BURNER; MODEL AFG (Chimney)
Yes (3708)
PLB-098-DD
PLB-098-VS
3,38 U
Model
Input
BTU/h
(*)
Firing rate
USGPH
(*)
AFUE
(***)
Nozzle
(Delavan)
(**)
Pump
pressure
(PSIG)
(*)
Head
Low firing
rate baffle
Burner tube
insertion
length (Inch)
ATC
Head/Air
setting
77,000
0.55
86.9%
0.50 - 60W
150
3,0
98,000
0.70
85.2%
0.60 - 60W
140
3,5
77,000
0.55
86.9% ‡
0.50 - 60W
150
3,0
98,000
0.70
85.2% ‡
0.60 - 60W
140
3,5
6 - Slot
LQ
1 3/4"
BECKET BURNER; MODEL NX (Chimney or DV)
Yes (32229)
PLB-098-DD
PLB-098-VS
NX56LQ
Model
Input BTU/h
(*)
Firing rate
USGPH
(*)
AFUE
(***)
Nozzle
(Delavan)
(**)
Pump
pressure
(PSIG)
(*)
Burner tube
insertion
length
(Inch)
Combustion air
adjustment
(Turbulator
/Damper)
77,000
0.55
86.6%
0.50 - 70A
150
0 /2,0
98,000
0.70
85.2%
0.60 - 70A
140
1 /3,5
77,000
0.55
86.6% ‡
0.50 - 70A
150
0 /2,0
98,000
0.70
85.2% ‡
0.60 - 70A
140
1 /3,5
Model
Input BTU/h
(*)
Firing rate
USGPH
(*)
AFUE
(***)
Nozzle
(Danfoss)
(**)
Pump
pressure
(PSIG)
(*)
Burner tube
insertion
length
(Inch)
Combustion air
adjustment
(Head/Air)
77,000
0.55
85.9%
0.50 - 60H
120
,60 / ,65 - 15%
98,000
0.70
85.2%
0.55 - 60H
165
,60 / ,65 - 30%
77,000
0.55
85.9% ‡
0.50 - 60H
120
,60 / ,65 - 15%
98,000
0.70
85.2% ‡
0.55 - 60H
165
,60 / ,65 - 30%
PLB-098-DD
PLB-098-VS
1 3/4"
CARLIN BURNER; MODEL EZ-LF
RIELLO BURNER; MODEL 40-F3 (Chimney)
2 3/4"
PLB-098-DD
PLB-098-VS
* INPUT & OUTPUT ADJUSTMENT
- Pump pressure can be adjusted to maintain proper firing rate.
- Increase pump pressure if flue gases temperature is under 400°F.
- Adjust the total flue gas temperature between 400°F and 575°F (330°F and 505°F) net approximately)
** Default Installed Nozzle in bold characters
*** AFUE values established after minimum 20 hours of operation.