The  manuf acturer, Williams Furnace Co., warrants this wall  f urnace or heater to the original purchaser under  the f ollowing conditi ons: 

LIMITED ONE-YEAR  WARRANTY 

1.  Any  part thereof  which  prov es to be def ectiv e in material or workmanship  within one y ear f rom date of  original purchase f or use will  be replaced at the Man

uf acturer’s 

option, FOB to its f actory . 

2.  No liability  is assumed by  the Manuf acturer f or remov al or installation labor costs, nor f or f reight or deliv ery  charges. 

LIMITED EXTENDED WARRANTY 

1.  In addition  to the abov e limited one-y ear warranty  on the complete unit, any  combustion chamber which  burns out or rusts under  normal installation, use and serv ice 

conditions during a period  of  nine y ears f ollowing expiration of  the one-y ear warranty  period  will  be exchanged f or a like or f unctionally  similar part.  

2.  No liability  is assumed by  the Manuf acturer f or remov al or installation labor costs, nor f or f reight or deliv ery  charges.  

LIMITATIONS 

1.  THIS LIMITED WARRANTY  IS THE ONLY  WARRANTY  MADE  BY  THE MANUFACTURER, IMPLIED WARRANTIES OF MERCHANTABILITY  OR FITNESS FOR ANY  

PARTICULAR PURPOSE ARE LIMITED TO  THE SAME  ONE Y EAR TERM  AS THE EXPRESS  WARRANTY .   UNDER NO CIRCUMSTANCES SHALL THE 
MANUFACTURER BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR CONTINGENT DAMAGES  OR EXPENSES  ARISING DIRECTLY  OR INDIRECTLY  
FROM ANY  DEFECT IN THE PRODUCT OR ANY  COMPONENT  OR FROM THE USE THEREOF .  THE REMEDIES SET  FORTH HEREIN ARE THE  EXCLUSIVE 
REMEDIES AVAILABLE  TO  THE USER AND ARE IN LIEU OF ALL OTHER REMEDIES.  

Some states do not allow  limitation on how  long an implied warranty  lasts, and some states do not allow  the exclusion or limi tation of  incidental or consequential 
damages, so the abov e limitations or exclusions may  not apply  to y ou. 

2.  This warranty  does not include any  charge f or labor or installation.  

3.  This warranty  does not extend to painted surf aces or to damage  or def ects resulting f rom accident, alteration, misuses or abu se or improper installation. 

4.  This warranty  does not cov er claims which do not inv olv e def ective workmanship or materials.  

DUTIES OF THE  CONSUMER 

1.  The  heating equipment must be installed by  a qualif ied installer and operated  in accordance with the installation and 

homeowner’s  instructions f urnished with the 

equipment. 

2.  Any  trav el, diagnostic costs, serv ice labor, and labor to repair  the def ectiv e unit will be the responsibility  of  the owner.  

3.  A bill of  sale, cancelled check, pay ment record or permit should be kept to v erif y purchase date to establish the warranty  period.  

4.  Hav e the installer enter the requested inf ormation in the space below.  

GENERAL 

1.  The  manuf acturer neither assumes nor authorizes  any  person to assume f or it any  other obligation or liability  in connection with said equipment. 

2.  Serv ice under this warranty  should be obtained by  contacting y our dealer.   Prov ide the dealer  with the model number, serial number, and purchase date v erif ication.  

3.  If , within a reasonable time af ter contacting y our dealer, satisf actory service has not been receiv ed, contact: Customer Serv ice Department, 250 West Laurel Street, 

Colton, CA 92324 f or assistance. 

4.  THIS WARRANTY  GIVES Y OU SPECIFIC LEGAL RIGHTS AND Y OU MAY  ALSO  HAVE OTHER RIGHTS WHICH VARY  FROM STATE  TO  STATE. 

 

 
Installation Record 

 
Model No. ____________________________________________________________ Serial No.__________________________   

Original Purchaser________________________________________________________________________________________   

Address  _______________________________________________________________________________________________   

City and State _________________________________________________________ Zip _______________________________   

Dealer _________________________________________________________________________________________________   

Address  _______________________________________________________________________________________________   

City and State _________________________________________________________ Zip _______________________________   

Installation Date ______________ Name ________________________________ Signature_________________________________  

 

(Dealer or authorized  representativ e who  certif ies that this appliance is installed in accordance with  M

anuf acturer’s instructions and local codes.) 

Содержание 6008531

Страница 1: ...a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS O...

Страница 2: ...ov er claims which do not inv olv e def ective workmanship or materials DUTIES OF THE CONSUMER 1 The heating equipment must be installed by a qualif ied installer and operated in accordance with the i...

Страница 3: ...tallation 21 23 Start Up Procedure 24 Operating Your Furnace 25 26 How To Care For Your Furnace 27 28 Furnace Technical Information 28 TROUBLESHOOTING CHART 29 30 Wiring Diagrams 30 Repair Parts 31 32...

Страница 4: ...or death 8 Install the furnace vent directly to the outdoors so that harmful combustible flue gases will not collect inside the building Follow the venting instructions for your type of installation e...

Страница 5: ...p forces air down along the front back and sides of the heat exchanger where it is discharged into the room The furnace cabinet is also constructed ofheavy gauge steel and has a neutral beige color en...

Страница 6: ...enclose the vent pipe from the top of the surface to the ceiling SIDE OUTLET GRILLE KIT 6702 as shown on Page 22 Fig 31 Allows you to direct heated air from the side of furnace into the same room NOT...

Страница 7: ...11 Recessed Mounting Place the furnace near the center of the space to be heated for good air circulation Do not put it behind a door or draperies Do not instatl the furnace in a closet alcove of smal...

Страница 8: ...e heated area The high cost of energy for home heating has brought about new materials and methods used to constructor remodel most current homes The improved construction and additional insulation ha...

Страница 9: ...special provisions are made such as ventilation grilles installed between connecting rooms Fig 6 page 10 shows the minimum area in square feet based on 8 foot ceiling heights required for different B...

Страница 10: ...00 square inches or 1 square inch per 1000 Btuh combined input of appliances in one room if combined input exceeds 100 000 Btuh WARNING Danger of property damage bodily injury or loss of life The adjo...

Страница 11: ...about 14 inches from the one found Drive finishing nails on the inside of this stud Draw wall cutout to required size as shown on Page 13 Fig 13 If wall studs are not on 16 inch centers see CLOSE OFF...

Страница 12: ...t to damage any furnace components while making any alternate hole Locate and drill one 1 1 1 2 inch hole at selected locations as shown on Page 12 Fig 11 and Page 13 Fig 13 or Page 14 Fig 14 Gas line...

Страница 13: ...nd electrical connections CUT CEILING OPENING Mark off and cut 3 1 2 x 12 inch rectangular hole in ceiling centered between wall studs The back edge of the opening should be about1 8 inch from the wal...

Страница 14: ...f Refer to typical venting system as shown on Page 16 Fig 18 Type B W gas vent shall extend from the header plate of the vented wall furnace to a point above the highest ceiling plate within a stud sp...

Страница 15: ...ailed between ends must be bent at 90 degrees INSTALL SURFACE VENT SURFACE MOUNT NOTE For surface mounting itwill be helpful to complete the gas piping supply to the furnace before installing the vent...

Страница 16: ...y attic insulation to allow the free circulation of air around oval vent piping Mounting Your Furnace To obtain adequate clearance for fastening furnace or to install gas supplyfittings it may be nece...

Страница 17: ...INATE AIR LEAKS FASTEN FURNACE BOTTOM SURFACE AND RECESSED MOUNT NOTE Fasteners are not furnished because of different requirements of various types of wall construction Fasten furnace to floor throug...

Страница 18: ...olumn Gas pressure and input to the burners must not exceed the rated inputand pressure shown on the rating plate On Natural Gas the manifold pressure should be 4 inches water column The manifold pres...

Страница 19: ...s may damage the gas valve and cause over firing which may result in heat exchanger failure Liquid petroleum L P Gas is heavier than air and it will settle in any low area including open depressions a...

Страница 20: ...r obstructions in the partition Then drill a 1 2 inch hole through wall at the selected location for thermostat 5 From the attic feed the thermostatcable or a stiff wire through wall until even with t...

Страница 21: ...used the furnace casing must be a minimum of 12 inches from an adjacent side wall as shown on Page 8 Fig 3D CUT CASING OPENING S Before setting the furnace into position cut a 5x7 inch rectangular ope...

Страница 22: ...ed REAR OUTLET ONLY Place Inner Boot in position and fasten with screws along the top and bottom edges only Place Damper Assemblyinside Inner Boot and fasten with one 1 screw on each side Thread chain...

Страница 23: ...IT MODEL 6704 Follow instructions for 2 WAY FRONT DIFFUSING GRILLE 6703 except furnace clearance to an adjacent wall must be 3 4 inch minimum See Page 8 Fig 3A TRIM STRIP KIT MODEL 4701 When desired o...

Страница 24: ...ctory sized orifices If L P gas having a different heating value is supplied orifices must be changed by a qualified service technician before the furnace is operated CHECK THE MANIFOLD GAS PRESSURE A...

Страница 25: ...limit switch shuts down the main burner to prevent overheating the furnace cabinet 4 A vent safety shutoff device shuts down the main burner to protect againstimproper venting of combustion products T...

Страница 26: ...f all electric power to the appliance 4 Remove control access panel 5 Turn gas control knob clockwise to OFF 6 Wait five 5 minutes to clear out any gas then smell for gas including near the floor If y...

Страница 27: ...cabinet door and front panel Clean any lint or dirt from fan blades fan motor and exposed air passages Use a brush Put 5 drops of SAE 20 oil in each of the two cups or oil tubes on the fan motor See F...

Страница 28: ...ESULT IN A YELLOW FLAME WHICH CAN PRODUCE CARBON MONOXIDE AND SOOT THIS CONDITION IF ALLOWED TO DEVELOP CAN LEAD TO BODILY INJURY INCLUDING DEATH IT IS IMPERATIVE THAT THE BURNER S BE KEPT GLEAN TO RE...

Страница 29: ...orifice plugged Clean or replace orifice if okay and still no gas flow to main burners proceed to Step F F Gas valve defective Replace defective gas valve 3 Burner comes ON but goes OFF before blow e...

Страница 30: ...loose on motor shaft Blow er may be rubbing on fan shroud Motor may need oiling Correct as needed B Expansion noise ticking Check installation casing may be tw isted or not level at time of installati...

Страница 31: ...Replacement Parts Accessories 31 6008531 6008532 6008531 6008532 34 35...

Страница 32: ...Replacements Parts 32...

Страница 33: ...22 Motor P321601 P321601 23 Motor Support 7B46 7B46 24 Vibration Isolator 4 required P022800 P022800 25 Drafthood Faceplate 7C85 7C85 26 Vent Safety Switch P321958 P321958 27 Drafthood 7B165 7B165 28...

Страница 34: ...ouple P321838 P321838 58 Flame Sensor 59 Pilot P179700 P179800 60 Burner Spacer 2 Required P018100 P018100 61 Burner Cast Iron P025600 P025600 62 Wire Assembly Vent Safety P322048 P322048A P322048 P32...

Страница 35: ...onnect the cord a t the receptacle connector located at the base of the furnace and remove the cord completely from the furnace Following the wiring diagram below make all the necessary wiring connect...

Страница 36: ...exactly a fire or explosion may result causing property damage personal injury or loss of life Williams Furnace Company 250 West Laurel Street Colton CA 92324 909 825 0993 FAX 909 824 8009 www wfc fc...