Williams Sound SoundPlus Infrared Receiver WIR RX3 Скачать руководство пользователя страница 4

Controls and Features: 

MOD 1 Front Panel 

Power Switch: 

Turns modulator power on/off. 

Power Indicator: 

Green LED indicates power on. 

Audio Level Indicators: 

“Ok” amber LED indicates proper audio input level. 
“Hi” red LED indicates excessive audio input level. 

Audio Level Control: 

Screwdriver rotary adjustment for audio input level. 

Infrared Test LED: 

Infrared LED provides a modulated IR signal for 
receiver testing, monitoring, audio source testing. 

Tape Output: 

RCA Jack provides unbalanced, line-level audio 
output signal for tape recorders, etc. 

MOD 1 Rear Panel 

Balanced Microphone-Level Input: 

Female XLR jack for use with low impedance (150 -
200

½

)  microphones. Supplies simplex DC power 

per DIN 45596 for condenser microphones. 

Balanced Line-Level Input: 

Female XLR jack for balanced, line-level inputs. 
Can also accept unbalanced input, and 4

W

, 8

W

, or 

16

speaker line. 

70V (Hi-Level) Input: 

Female XLR jack for direct connection to a 70V or 
25V speaker line. 

Input Level Switch: 

Three-position switch selects mic-level, line-level, or 
70V input for the XLR input jack. 

Unbalanced Audio Inputs: 

Two RCA jacks for unbalanced line-level audio 
inputs. Inputs are mixed internally with the balanced 
input signal. 

High-Pass Filter: 

Three position switch provides 6dB/octave low-
frequency roll-off to reduce noise, improve speech 
intelligibility, compensate for typical high-frequency 
hearing loss. 

Modulator Outputs: 

Two F-type connectors provide 95 kHz frequency 
modulated outputs to feed two TX3 Transmitters. 

Power Input: 

Two-screw terminals for low-voltage power supply, 
24VAC, 50 or 60Hz, 2.4VA. 

Audio Input

Balanced

Line

Mic

70V

Model WIR MOD1 Infrared System Modulator

Input Level

Audio Inputs 

Unbalanced

Left

Right

Hi-Pass Filter

20 Hz

175 Hz

725 Hz

6dB/octave

Modulator 

Out

Modulator 

Out 

Power: 24 VAC, 60 Hz, 50VA

75 Ohm

75 Ohm

Made in USA

Williams Sound Corp.

Power: 24 VAC, 

50-60 Hz, 10VA

Plug

Tape

Out 

Infrared

Test Out 

Audio Level

Hi

Ok

Power

 MOD 1 Infrared System Modulator

Adjust

Williams Sound 

+

-

0

I

Fig. 2: MOD 1 Front & Rear Panels 

Williams Sound 

®

Helping People Hear

Содержание SoundPlus Infrared Receiver WIR RX3

Страница 1: ...de User Manual SoundPlus WIR TX300 Infrared System Large Area Infrared Listening System Modulator Model WIR MOD 1 Transmitter Model WIR TX3 Receiver Models WIR RX1 RX3 RX4 Williams Sound Helping Peopl...

Страница 2: ...95 kHz Carrier Cable Connection Modulator Installation Power Connection 95 kHz Carrier Cable Connection Audio Source Connection Using a Microphone Hi Pass Filter Setting Testing the System Receiver In...

Страница 3: ...itters The transmission is confined within opaque walls if security is an issue such as courtrooms and corporate boardrooms The Williams Sound Infrared System can also be used where multiple systems a...

Страница 4: ...r 25V speaker line Input Level Switch Three position switch selects mic level line level or 70V input for the XLR input jack Unbalanced Audio Inputs Two RCA jacks for unbalanced line level audio input...

Страница 5: ...ion Out Connects to the Modulation In jack of of the next TX3 transmitter in the chain when multiple transmitters are used Mounting Bracket An omnidirectional mounting bracket is included with the Tra...

Страница 6: ...e left side of the front wall and the other on the right hand side The two transmitters will be connected together with a coaxial cable The infrared illumination pattern from a single transmitter is a...

Страница 7: ...te for the mounting surface wood screws lag bolt wall anchor to attach the mounting plate Recommended fastener size is 1 4 Step 2 Attach the clamp plate to the rear of the transmitter using 2 1 4 x 20...

Страница 8: ...to switch AC power to the outlet OFF at the fuse or circuit breaker Remove the wallplate cover screw and plug the transformer into the outlet Secure the transformer with the cover plate screw Turn the...

Страница 9: ...th and install F connectors on both ends Additional RG59 coax can be added up to 1000 feet maximum Make sure you leave some slack at each end Step 2 Install the F connectors on each end of the cable Y...

Страница 10: ...For stereo sources use an additional RCA to RCA cable and connect the left and right signals to the two inputs on the MOD 1 They will be mixed into a mono signal for transmission Three Channel Unbalan...

Страница 11: ...o adjust the angle of the transmitter s to obtain the best coverage If coverage is not adequate additional transmitter panels must be used Receiver Operating Instructions Receiver Model WIR RX1 The RX...

Страница 12: ...s in the receivers they may leak and damage the receiver Rechargeable Batteries The RX3 receivers can also use a rechargeable battery We recommend only the 7 cell 8 4 Volt types BAT 003 A fully charge...

Страница 13: ...vers that aren t working 2 If none of the receivers work check to see if the power and 95 kHz carrier cable are connected to the transmitter and the Power like is ON 3 Check to see if the modulator is...

Страница 14: ...rain Transmitter shuts off when modulation Modulation Input signal is not present Operating Req 0 50 C ambient temperature non Modulation Output condensing non corrosive atmosphere Coverage Area 10 00...

Страница 15: ...Williams Sound Corp 10321 West 70th St Eden Prairie MN 55344 3446 U S A 800 843 3544 952 943 2252 FAX 952 943 2174 1996 Williams Sound Corp MAN 046C...

Отзывы: